The Allen-Bradley 402388-2K potentiometer is manufactured as an electric potentiometer rated at 15 Horsepower and 460 Volts AC and made for control drivers. It can be installed in a NEMA enclosure and it can tolerate 5 to 95 percent relative humidity without condensation.
We sell industrial automation parts backed by our 2-year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
Brand | Allen-Bradley / Rockwell Automation |
---|---|
Series | 402388 Potentiometers |
Part Number | 402388-2K |
Product Type | Reliance Electric potentiometer |
Power Rating | 15 HP, 460 V AC |
Input Power | 24V DC |
Enclosure | NEMA Type 1, 2 |
Frequency Range | 0-60 Hz expandable to 240 Hz |
Minimum Storage Temperature | -40 degrees Celsius |
Maximum Storage Temperature | 65 degrees Celsius |
Protection | Internal input fuse with 100,000 amps fault current |
Input Current | 4-20mA and 0-20 mA |
Operator Voltage | 115V AC |
Display Module | LED regulator |
Control | Remote reset and motor overload |
Maximum Elevation | 3300 ft |
The 402388-2K potentiometer is an Allen-Bradley and Reliance Electric potentiometer that is rated for 15 Horsepower output and 460 Volts AC voltage. It can be installed in a NEMA enclosure and it can operate safely in a relative ambient humidity range of 5 to 95% without condensation. The storage temperature range is -40 to 65 degrees Celsius in a clean and dry environment. The 402388-2K potentiometer consists of controllers and a 3-phase AC motor that work together. It must be connected to the controllers of local remote devices to measure their power and speed. Its frequency normally ranges from 0 to 60 Hertz, but this frequency can be expanded to 240 Hertz with nearly consistent power throughout the frequency range. Internal fuses and internal reactors can handle up to 100,000 Amps of fault current and they are easy to replace. Additionally, there is a line transient protection feature to prevent a power surge from harming the potentiometer that includes a fault reset pushbutton.
Other features of the Allen-Bradley and Reliance Electric 402388-2K potentiometer include a 3-phase output voltage regulator that is rated at +/-1% of the selected voltage range within +/-10% of the rated plant power. It has a fast-acting fault indicator LED with an automatic shutdown function that activates whenever the following errors occur: overvoltage, overcurrent, undervoltage, over-temperature ground fault, and DC Bus fault errors. The 402388-2K potentiometer has an input current rating of 0 to 20 milliamps at 0 to 10 Volts DC voltage, and it can also support a current range of 4 to 20 milliamps. It is designed to reduce the harmonic current to 20%, and to reduce the fundamental to 6% from 14%, which is useful in dynamic braking, and in input disconnection.