The 1756-L71 from Allen Bradley serves as a versatile programmable automation controller suited for a multitude of applications. This unit supports up to 32 controller tasks and offers strong communication capabilities, including various network protocols for seamless integration in diverse environments.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Allen Bradley |
|---|---|
| Product Type | Programmable Automation Controller |
| Product Line | ControlLogix |
| Part Number | 1756-L71 |
| UPC | 612598876013 |
| Weight | 1.00 lbs (0.45 kg) |
| Number of Controller Tasks | 32 Tasks |
| Communications Ports | 1 USB 2.0 Port |
| Communication Options | Ethernet/IP, ControlNet, DeviceNet, Data Highway Plus, Remote I/O, SynchLink, and Other Third-Party Networks |
| Maximum Number of Controller Connections Supported | 500 |
| Input and Current Ratings | 5 Milliamps at 1.2 Volts DC; 800 Milliamps at 5.1 Volts DC |
| Power Dissipation Rating | 2.5 Watts |
| Thermal Dissipation Rating | 8.5 BTU/hr |
| Isolation Voltage | 30 Volts (Continuous) |
| Enclosure Type | Open-Style |
| Operating Temperature Range | 0 to 60 Degrees Celsius |
The model 1756-L71 is a programmable automation controller from Allen Bradley’s ControlLogix series. It has the capacity to manage 32 distinct tasks, making it suitable for a wide range of automation requirements. This controller includes a USB 2.0 port, which allows for easy data transfer and connectivity. With its ability to support up to 500 connections, the device allows extensive networking capabilities to cater to complex control environments.
The communication options available with this controller are extensive, featuring Ethernet/IP, ControlNet, DeviceNet, Data Highway Plus, Remote I/O, and SynchLink, ensuring compatibility with various third-party networks. The input ratings reveal 5 milliamps at 1.2 volts DC and 800 milliamps at 5.1 volts DC, indicating its efficient performance under specified conditions.
In terms of power handling, the unit has a dissipation rating of 2.5 watts, with a thermal dissipation rate of 8.5 BTU/hr. The device maintains a continuous isolation voltage of 30 volts, contributing to its robustness and safety in operation. The open-style enclosure allows for convenient installation while ensuring adequate airflow for cooling. This controller functions optimally within ambient temperatures between 0 and 60 degrees Celsius, making it versatile for different operational settings.
| Revision Part # | Also known as | |
|---|---|---|
| 1756-L71 Ser A | 1756-L71/A, Series A, Rev A | |
| 1756-L71 Ser B | 1756-L71/B, Series B, Rev B | |
| Don't see your particular revision? Contact us now. | ||
Yes, the 1756-L71 includes a free 2-year DO Supply warranty. You can upgrade to a 3-year warranty at checkout for even more protection.
DO Supply, Inc. offers a variety of repair services for the 1756-L71.
The 1756-L71 has a user memory of 2 MB and an I-O Memory of 0.98?
The 1756-L71 has a dissipation of around 2.5 Watts.
The 1756-L71 does not require an enclosure.
The memory card enables the user to keep a copy of the project on the controller without the need to maintain power to the controller. The memory card can be used to store the contents of the user memory when project is stored.
Instead of batteries, the Logix 5570 family (including 1756-L71) uses Energy Storage Modules (ESM). The ESM allows this unit to save the program to the onboard nonvolatile storage (NVS) memory of the controller even after power is turned off to the rack or the controller is taken out of a powered on rack.
No. It only has 1 USB port, however, Ethernet port may be added via optional communication adapters.
The 1756-L71 has 2 MB user memory, 0.98 I/O memory and 1 GB non-volatile memory.
No. This controller requires a ControlLogix chassis to mount.
Identifying Controller Faults with the 1756-L71
It is important to understand the 1756-L71 device’ possible faults and how to address them. When the PAC encounters an error, the PAC’s Red indicator light is lit and provides an error code corresponding to the event through the front panel display. This error code can be evaluated and counter check within the fault database to identify the cause and perform necessary corrective actions. Capturing the PLC’s error code is important as it provides the root cause of the problem. Performing a general fix without knowing the cause may lead to another fault instance in the future resulting to process stoppage and loss of production. A Fault is initially identified via the CPU Status Indicator LEDs.