140M-L8P-D40

140M-L8P-D40

Description: The 140M-L8P-D40 circuit breaker is a motor protection circuit breaker. It is part of the Allen-Bradley Bulletin 140M product line which includes 0.16 to 1200 Amps rated circuit breakers. The Bulletin 140M motor circuit protectors provide short circuit protection, but overload protection needs to be provided separately. The rated operational current for the 140M-L8P-D40 circuit breaker is 400 Amps. The tripping module on the breaker is a magnetic trip unit.
Rated 4.9 with 20 reviews

top legal disclaimer bottom legal disclaimer
credit cards accepted
better business bureau

Available Now

Submit RFQ for 140M-L8P-D40

Add more parts to quote

Description:

The 140M-L8P-D40 circuit breaker is a motor protection circuit breaker. It is part of the Allen-Bradley Bulletin 140M product line which includes 0.16 to 1200 Amps rated circuit breakers. The Bulletin 140M motor circuit protectors provide short circuit protection, but overload protection needs to be provided separately. The rated operational current for the 140M-L8P-D40 circuit breaker is 400 Amps. The tripping module on the breaker is a magnetic trip unit.



Warranty: 1 year DO Supply Warranty Included
Shipping: Worldwide shipping via DHL, UPS, Fedex, and TNT
Repairs: We offer repair service for the 140M-L8P-D40.
Exchange: Exchange credit for your defective unit available.

To Speak to a sales representative for pricing & lead time:

phone

International
919-205-4392

Rated 4.9 with 20 reviews

    Technical Specifications for 140M-L8P-D40

BrandAllen-Bradley / Rockwell Automation
Series140M Circuit Breakers
Part Number140M-L8P-D40
Product typeMotor protection circuit breaker
Pole3
FrameL
Operating current400 Amps
Trip unitMagnetic
Operating temperature-8.9 to 60 degrees Celsius
Power loss53 Watts
BrandAllen-Bradley / Rockwell Automation
Series140M Circuit Breakers
Part Number140M-L8P-D40
Product typeMotor protection circuit breaker
Pole3
FrameL
Operating current400 Amps
Trip unitMagnetic
Operating temperature-8.9 to 60 degrees Celsius
Power loss53 Watts

About 140M-L8P-D40

The 140M-L8P-D40 circuit breaker is a motor protection circuit breaker. It is part of the Allen-Bradley Bulletin 140M product line which includes 0.16 to 1200 Amps rated circuit breakers. The bulletin 140M motor protection circuit breakers provide short circuit protection, but overload protection needs to be provided separately. A visible trip indication is available on the 140M-L8P-D40 circuit breaker. Agency approvals for the Bulletin 140M devices include the CE and CSA approval ratings. Furthermore, the Bulletin 140M devices conform to multiple industrial standards including the IEC, CSA, and UL 489 / UL 508 standards. The circuit breaker comes in an L-frame enclosure. The maximum current rating for the L-frame breakers is 600 Amps. Accessories available for the 140M-L8P-D40 circuit breaker from Allen-Bradley include trip indication contacts, auxiliary contacts, and flexible cable operators.

 

The 140M-L8P-D40 circuit breaker is engineered to provide manual switching, to disconnect motor circuits, and to provide branch circuit and short circuit protection. The rated operational current for the 140M-L8P-D40 circuit breaker is 400 Amps. The tripping module on the circuit breaker is a magnetic trip unit. The Horsepower output power ratings which the 140M-L8P-D40 circuit breaker can support are 100, 200, 250, and 300 Horsepower at 200, 230, 460, and 575 Volts AC, respectively, and the kilowatt output ratings are 90, 160, 200, and 250 kilowatts at 230, 400/415, 500, and 690 Volts AC, respectively. The magnetic trip setting on the circuit breaker can be set at 2000, 2250, 2500, 2750, 3000 3250, 3500, 3750, and 4000 Amps. Only trained and experienced technicians should be involved in the designing and installation of systems which include the 140M-L8P-D40 circuit breaker. The power should be disconnected prior to the installation and servicing processes. Failure to do so could lead to equipment damage, injury, and even death.

Repair Services for 140M-L8P-D40

Type Lead Time Price Action
Repair Service 2-4 weeks $434cartAdd to Cart

Our highly skilled technicians can repair your 140M-L8P-D40. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Technical Specifications
BrandAllen-Bradley / Rockwell Automation
Series140M Circuit Breakers
Part Number140M-L8P-D40
Product typeMotor protection circuit breaker
Pole3
FrameL
Operating current400 Amps
Trip unitMagnetic
Operating temperature-8.9 to 60 degrees Celsius
Power loss53 Watts
BrandAllen-Bradley / Rockwell Automation
Series140M Circuit Breakers
Part Number140M-L8P-D40
Product typeMotor protection circuit breaker
Pole3
FrameL
Operating current400 Amps
Trip unitMagnetic
Operating temperature-8.9 to 60 degrees Celsius
Power loss53 Watts
About

The 140M-L8P-D40 circuit breaker is a motor protection circuit breaker. It is part of the Allen-Bradley Bulletin 140M product line which includes 0.16 to 1200 Amps rated circuit breakers. The bulletin 140M motor protection circuit breakers provide short circuit protection, but overload protection needs to be provided separately. A visible trip indication is available on the 140M-L8P-D40 circuit breaker. Agency approvals for the Bulletin 140M devices include the CE and CSA approval ratings. Furthermore, the Bulletin 140M devices conform to multiple industrial standards including the IEC, CSA, and UL 489 / UL 508 standards. The circuit breaker comes in an L-frame enclosure. The maximum current rating for the L-frame breakers is 600 Amps. Accessories available for the 140M-L8P-D40 circuit breaker from Allen-Bradley include trip indication contacts, auxiliary contacts, and flexible cable operators.

 

The 140M-L8P-D40 circuit breaker is engineered to provide manual switching, to disconnect motor circuits, and to provide branch circuit and short circuit protection. The rated operational current for the 140M-L8P-D40 circuit breaker is 400 Amps. The tripping module on the circuit breaker is a magnetic trip unit. The Horsepower output power ratings which the 140M-L8P-D40 circuit breaker can support are 100, 200, 250, and 300 Horsepower at 200, 230, 460, and 575 Volts AC, respectively, and the kilowatt output ratings are 90, 160, 200, and 250 kilowatts at 230, 400/415, 500, and 690 Volts AC, respectively. The magnetic trip setting on the circuit breaker can be set at 2000, 2250, 2500, 2750, 3000 3250, 3500, 3750, and 4000 Amps. Only trained and experienced technicians should be involved in the designing and installation of systems which include the 140M-L8P-D40 circuit breaker. The power should be disconnected prior to the installation and servicing processes. Failure to do so could lead to equipment damage, injury, and even death.

Repairs
Type Lead Time Price Action
Repair Service 2-4 weeks $434cartAdd to Cart

Our highly skilled technicians can repair your 140M-L8P-D40. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Type Lead Time Price Action
Repair Service 2-4 weeks $434cartAdd to Cart

Our highly skilled technicians can repair your 140M-L8P-D40. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

PDF