SLC 504

 
 
 
 
 
Rated 4.4 with 5 reviews

top legal disclaimer bottom legal disclaimer
credit cards accepted
better business bureau

SLC 504

Revisions: Ser A 
Description: The Allen-Bradley SLC 504 is a SLC 500 SLC 504 Processor. This SLC 504 Processor has the following part numbers: 1747-L541, L542, or L543. These processors have 4096 Inputs and 4096 Outputs.
Available Now
Request a quote for SLC 504

Description:

The Allen-Bradley SLC 504 is a SLC 500 SLC 504 Processor. This SLC 504 Processor has the following part numbers: 1747-L541, L542, or L543. These processors have 4096 Inputs and 4096 Outputs.



no auth
no auth mobile
disclaimer
credit cards
better business bureau
Revisions: Ser A 

Warranty: 1 year DO Supply Warranty Included
Shipping: Worldwide shipping via DHL, UPS, Fedex, and TNT
Repairs: We offer repair service for the SLC 504.
Exchange: Exchange credit for your defective unit available.

To Speak to a sales representative for pricing & lead time:

phone

International
919-205-4392
phone

International
919-205-4392

Rated 4.4 with 5 reviews

    Technical Specifications for SLC 504

ManufacturerRockwell Automation
BrandAllen-Bradley
Part Number/Catalog No.1747-L541, L542, or L543
SeriesSLC 500
ProcessorSLC 504 Processor
Inputs4096
Outputs4096
Analog I/O480
User Memory16,000, 32,000, or 64,000 Words
Program Scan Time0.9 milliseconds
I/O Scan Time0.225 milliseconds
I/O Chassis3
Chassis Module Slots30
CommunicationDH+, RS-232
Backup MemoryFlash
ManufacturerRockwell Automation
BrandAllen-Bradley
Part Number/Catalog No.1747-L541, L542, or L543
SeriesSLC 500
ProcessorSLC 504 Processor
Inputs4096
Outputs4096
Analog I/O480
User Memory16,000, 32,000, or 64,000 Words
Program Scan Time0.9 milliseconds
I/O Scan Time0.225 milliseconds
I/O Chassis3
Chassis Module Slots30
CommunicationDH+, RS-232
Backup MemoryFlash

About SLC 504

The Allen-Bradley SLC 504 controller module is a programmable controller module from the Allen-Bradley SLC 500 control system that is designed to provide power and flexibility in a wide range of control applications. The SLC 504 processor module features 16 K, 32 K, and 64 K program memory size options, with high-speed program process performance (0.9 milliseconds), and it is capable of providing control for up to 4096 discrete remote and local input and output points. The SLC 504 processor module occupies the first slot of the first chassis, and a single processor module is sufficient for a whole system. It has a maximum backplane current draw of 1 Amp at 5 Volts DC, 200 mA at 24 Volts DC. 

The SLC 504 modular I/O system can be configured to a maximum of 3 chassis (30 total slots), and it can support anything from 4 to 4096 I/O points. It has a built-in Allen-Bradley Data Highway Plus (DH+) port that supports high-speed communication of up to 230.4 Kilo-Bauds, messaging capability with the SLC 500, PLC-2, PLC-5, and ControlLogix processors, and also high-speed processor-to-processor module communications. The SLC 504 module also has a built-in RS-232 port that supports remote point-to-point communication, DH-485 communication, and MODBUS RTU communication. It has a write-protectable EPROM flash memory module option with a 64K word non-volatile memory capacity for program backup. The SLC 504 module has a battery-backed RAM (Random Access Memory) with a backup time of up to 5 years, and an internal clock/calendar with ±54 seconds/month accuracy. It can be programmed easily by using the RSLogix Ladder logic programming software that provides flexible point-and-click configuration, editing, troubleshooting, and diagnostic tools for reduced development time and increased productivity.

Repair Services for SLC 504

Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote
Our highly skilled technicians can repair your SLC 500 SLC 504. All of our repairs come with a 1 Year Warranty. Please contact us for additional information.

Revisions for SLC 504

Please refer to the manual for more information about the SLC 504 such as the wiring diagrams, data sheets, firmware information and migration or obsolescence details.

Revision Part # Also Known as Availability
SLC 504 Ser A
SLC 504/A, Series A, Rev A Request Quote
Common misspellings:
  • S1C 504
  • SLC 5o4
  • SLC 50A
Technical Specifications
ManufacturerRockwell Automation
BrandAllen-Bradley
Part Number/Catalog No.1747-L541, L542, or L543
SeriesSLC 500
ProcessorSLC 504 Processor
Inputs4096
Outputs4096
Analog I/O480
User Memory16,000, 32,000, or 64,000 Words
Program Scan Time0.9 milliseconds
I/O Scan Time0.225 milliseconds
I/O Chassis3
Chassis Module Slots30
CommunicationDH+, RS-232
Backup MemoryFlash
ManufacturerRockwell Automation
BrandAllen-Bradley
Part Number/Catalog No.1747-L541, L542, or L543
SeriesSLC 500
ProcessorSLC 504 Processor
Inputs4096
Outputs4096
Analog I/O480
User Memory16,000, 32,000, or 64,000 Words
Program Scan Time0.9 milliseconds
I/O Scan Time0.225 milliseconds
I/O Chassis3
Chassis Module Slots30
CommunicationDH+, RS-232
Backup MemoryFlash
About

The Allen-Bradley SLC 504 controller module is a programmable controller module from the Allen-Bradley SLC 500 control system that is designed to provide power and flexibility in a wide range of control applications. The SLC 504 processor module features 16 K, 32 K, and 64 K program memory size options, with high-speed program process performance (0.9 milliseconds), and it is capable of providing control for up to 4096 discrete remote and local input and output points. The SLC 504 processor module occupies the first slot of the first chassis, and a single processor module is sufficient for a whole system. It has a maximum backplane current draw of 1 Amp at 5 Volts DC, 200 mA at 24 Volts DC. 

The SLC 504 modular I/O system can be configured to a maximum of 3 chassis (30 total slots), and it can support anything from 4 to 4096 I/O points. It has a built-in Allen-Bradley Data Highway Plus (DH+) port that supports high-speed communication of up to 230.4 Kilo-Bauds, messaging capability with the SLC 500, PLC-2, PLC-5, and ControlLogix processors, and also high-speed processor-to-processor module communications. The SLC 504 module also has a built-in RS-232 port that supports remote point-to-point communication, DH-485 communication, and MODBUS RTU communication. It has a write-protectable EPROM flash memory module option with a 64K word non-volatile memory capacity for program backup. The SLC 504 module has a battery-backed RAM (Random Access Memory) with a backup time of up to 5 years, and an internal clock/calendar with ±54 seconds/month accuracy. It can be programmed easily by using the RSLogix Ladder logic programming software that provides flexible point-and-click configuration, editing, troubleshooting, and diagnostic tools for reduced development time and increased productivity.

Repairs
Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote
Our highly skilled technicians can repair your SLC 500 SLC 504. All of our repairs come with a 1 Year Warranty. Please contact us for additional information.
Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote
Our highly skilled technicians can repair your SLC 500 SLC 504. All of our repairs come with a 1 Year Warranty. Please contact us for additional information.
Revisions

Please refer to the manual for more information about the SLC 504 such as the wiring diagrams, data sheets, firmware information and migration or obsolescence details.

Revision Part # Also Known as Availability
SLC 504 Ser A
SLC 504/A, Series A, Rev A Request Quote

Common misspellings:
  • S1C 504
  • SLC 5o4
  • SLC 50A