Product image is representative; revision or series may vary. Contact us to request a specific version.
The 2711P-RN6is a PanelView Plus / PanelView Plus CE / PanelView Plus 6 communication module. This module is a DH+/ RIO / DH-485 optional adapter module. It comes with One (1) Data High Plus (DH+) / Remote I/O (RIO) and One (1) DH-485 communication ports. It also comes with status LED indicators providing module operational state.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Allen Bradley |
|---|---|
| Product Type | Communication Module |
| Product Line | Panelview Plus |
| Part Number | 2711P-RN6 |
| UPC | 662073083672 |
| Weight | 0.75 lbs (0.34 kg) |
| Series | Manufacturer: |
| Rockwell Automation | Brand: |
| Allen-Bradley | Compatible Product Family: |
| PanelView Plus / PanelView Plus CE / PanelView 6 Operator Terminals | Product Type: |
| DH+ / RIO / DH485 communication adapter | Part Number: |
| 2711P-RN6 | No. of DH+ / RIO ports: |
| One (1) DH+ / RIO | No. of DH485 port |
| One (1) DH485 port | No. of Network Access Port (NAP): |
| None | Supported operator terminals: |
| PanelView Plus 700-1500; PanelView Plus CE 700-1500; PanelView Plus 6 700 - 1500 | DH485 Communication cable: |
| Belden 3106A or 9842 | DH+ / RIO communication cable: |
| Belden 9463 twin-axial or equivalent cable | DH+ / RIO trunk cable length: |
| 3048 m (10,000 ft) | Removal and Insertion under power: |
| Retaining Screw size | M3 metric screw 5 millimeters long |
| Communication | RS-232, DH+/DH-485 |
| Communication Cable | 1747-AIC |
The Allen-Bradley 2711P-RN16 is an optional communication adapter. This adapter is installed on top of an existing Logic module, enabling Data Highway Plus (DH+), Remote I/O (RIO) and DH-485 network connectivity. It is compatible for use with PanelView Plus / PanelView Plus CE and PanelView Plus 6 graphic operator terminals. Specifically, it may only be installed with operator terminals having screen size of 7-inch to 15-inch or 700 to 1500 range. When used with PanelView Plus 6, only Data Highway Plus (DH+) and DH485 is supported as the PanelView Plus 6 does not support native Remote I/O communications, even with a 2711P-RN6 communication module. Additionally, the 2711P-RN6 is not compatible with PanelView Plus 7 graphic operator terminals.
The 2711P-RN6 comes with One (1) DH485 port and One (1) DH+ / RIO communication ports. Both ports are phoenix connectors with the DH485 having 6 pins and DH+ / RIO having 3 connection pins. Additionally, this communication adapter has Two (2) LED status indicators that indicate Channel is not online when OFF, Device is only node on the network when Blinking green, Device is online and receiving token when Solid green, DH-485: Duplicate node / DH+: Parity error when Blinking red and Failed self-test when Solid red.
The DH+ and RIO network supports multi-node communication and may cover long distances. These communication protocol supports daisy-chain topology and fast data transmission rate. It requires use of the 1770-CD or the Belden Blue Hose cable. For DH-485 communication, it also support daisy chain topology and requires use of Belden #3106A or #9842.
This module has indicators that show the status of the DH-485 or the DH+ network connections. On the DH-485 network, the controller can send and receive messages to and from other controllers on the network. The Allen-Bradley 2711P-RN6 does support remote programming and monitoring. Keep in mind that excessive traffic through a DH-485 connection may affect performance and result in loss of time and efficiency. The Allen-Bradley 2711P-RN6 network sends information from 1 device to another. This module monitors process status and device status. It supports data acquisition and monitoring, program uploading and downloading, and supervisory controls. The maximum network length for this module is 4000 feet. This module can connect with up to 32 devices at a time. This module can also add and remove nodes without disrupting the network. The protocol that controls the transfer of messages on the DH-485 network supports 2 classes of devices: initiators and responders. The maximum number of addresses that the initiators will seek before wrapping to zero is the value at the maximum configurable node address. The default value for is 31 for all the initiators and responders. The 2711P-RN6 must have at least 1 initiator on its network. The shipping weight of the 2711P-RN6 is 3 pounds and the shipping dimensions are 11 x 8 x 6 inches.
| Revision Part # | Also known as | |
|---|---|---|
| 2711P-RN6 Ser A | 2711P-RN6/A, Series A, Rev A | |
| 2711P-RN6 Ser B | 2711P-RN6/B, Series B, Rev B | |
| 2711P-RN6X | 2711P-RN6/X, Series X, Rev X | |
| Don't see your particular revision? Contact us now. | ||
Yes, the 2711P-RN6 includes a free 2-year DO Supply warranty. You can upgrade to a 3-year warranty at checkout for even more protection.
The 2711P-RN6 is compatible with 700-1500 models of the PanelView Plus terminals.
The 2711P-RN6 has a shipping weight of 3 pounds and shipping dimensions of 11 x 8 x 6 inches.
Submit quote request, send us an email, or call +1 (919) 205-4392 for our best price.
Yes, DO Supply offers repair services for a variety of Allen-Bradley products, such as the 2711P-RN6. For more information or to request a repair quote, please click here.
Yes, however, RIO protocol is not supported.
For DH-485, communication cable used is Belden 3106A or 9842 cable. For DH+ / RIO, use Belden 9463 twin-axial or equivalent cable, catalog number 1770-CD.
No. This communication adapter may only be used with terminals having screen size of 7-inch to 15-inches.
DH+/DH-485 communication module for Panelview Plus 700-1500