ED2020

Available Now
Request a Quote for ED2020
The Eaton ED2020 Molded Case Circuit Breaker is in the C Series and has 2 Pole(s). The module has 20 Trip Amps and a Thermal-Magnetic Trip Unit.
Warranty: 1 year DO Supply Warranty Included
Shipping: Worldwide shipping via DHL, UPS, Fedex, and TNT
Repairs: We offer repair service for the ED2020.
Exchange: Exchange credit for your defective unit available.

To speak to a sales representative for pricing & lead time:

phone

International
919-205-4392

ED2020

Description: The Eaton ED2020 Molded Case Circuit Breaker is in the C Series and has 2 Pole(s). The module has 20 Trip Amps and a Thermal-Magnetic Trip Unit.
Rated 4.9 with 6 reviews
top legal disclaimer
top legal disclaimer

credit cards accepted
better business bureau

Available Now

Submit RFQ for ED2020

Add more parts to quote

Warranty: 1 year DO Supply Warranty Included
Shipping: Worldwide shipping via DHL, UPS, Fedex, and TNT
Repairs: We offer repair service for the ED2020.
Exchange: Exchange credit for your defective unit available.

To speak to a sales representative for pricing & lead time:

phone

International
919-205-4392

Rated 4.9 with 6 reviews

    Technical Specifications for ED2020

Part Number/Catalog No.ED2020
Product TypeMolded Case Circuit Breaker
SeriesC
FrameF
Pole(s)2
Trip Amps65 kA at 240V
Interrupting Capacity3 lb
WeightThermal-Magnetic
Trip Unit2.75 x 6 x 3.38 in.
Part Number/Catalog No.ED2020
Product TypeMolded Case Circuit Breaker
SeriesC
FrameF
Pole(s)2
Trip Amps65 kA at 240V
Interrupting Capacity3 lb
WeightThermal-Magnetic
Trip Unit2.75 x 6 x 3.38 in.

About ED2020

The ED2020 is a molded case circuit breaker. It is manufactured by the Eaton Corporation. The ED2020 features as an F Frame size module and it is also classified as an ED circuit breaker type. The frequency rating for the ED2020 is 50 or 60 Hertz and it comes as a complete breaker frame type featuring a load-side terminal option. The ED2020 comes with a voltage rating of 240 Volts AC and has an option for a 125 Volts DC voltage rating. The amperage rating for the ED2020 is 20 Amps and it produces 65 kVA at 240 Volts AC. The ED2020 comes with an interruption capacity of 3 pounds and it features a thermal-magnetic trip type or specifically fixed thermal and fixed magnetic trip types. The ED2020 comes as a two-pole module. The shipping dimensions for the ED2020 are a length of 3.38 inches, a height of 2.75 inches, with a width of 2.75 inches. The ED2020 also weighs 2.9 pounds and comes with a UL listing.

The Eaton’s F-Frame circuit breakers are HACR rated and all the circuit breakers that are 10 to 30 Amps circuit breakers are suitable for high-intensity discharge use. These F-Frame circuit breakers are also suitable for reverse use. The line and load terminal circuit breakers provide a wire connection capability for the circuit breakers. The F-Frame circuit breakers also feature load terminals that are standard for the equipment. Note that the circuit breakers that feature DC ratings apply to the substantially non-inductive circuits. The circuit breaker should also be installed by a trained technician.

Repair Services for ED2020

Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your ED2020. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Dimensions For ED2020

Size
Input Type
Panel Cutout Height in mm
Panel Cutout Width in mm
Terminal Height in mm
Terminal Width in mm
Terminal Overall Depth in mm
Terminal Mounted Depth in mm

Dimensions For ED2020

Resolutions For ED2020

Technical Specifications
Part Number/Catalog No.ED2020
Product TypeMolded Case Circuit Breaker
SeriesC
FrameF
Pole(s)2
Trip Amps65 kA at 240V
Interrupting Capacity3 lb
WeightThermal-Magnetic
Trip Unit2.75 x 6 x 3.38 in.
Part Number/Catalog No.ED2020
Product TypeMolded Case Circuit Breaker
SeriesC
FrameF
Pole(s)2
Trip Amps65 kA at 240V
Interrupting Capacity3 lb
WeightThermal-Magnetic
Trip Unit2.75 x 6 x 3.38 in.
About

The ED2020 is a molded case circuit breaker. It is manufactured by the Eaton Corporation. The ED2020 features as an F Frame size module and it is also classified as an ED circuit breaker type. The frequency rating for the ED2020 is 50 or 60 Hertz and it comes as a complete breaker frame type featuring a load-side terminal option. The ED2020 comes with a voltage rating of 240 Volts AC and has an option for a 125 Volts DC voltage rating. The amperage rating for the ED2020 is 20 Amps and it produces 65 kVA at 240 Volts AC. The ED2020 comes with an interruption capacity of 3 pounds and it features a thermal-magnetic trip type or specifically fixed thermal and fixed magnetic trip types. The ED2020 comes as a two-pole module. The shipping dimensions for the ED2020 are a length of 3.38 inches, a height of 2.75 inches, with a width of 2.75 inches. The ED2020 also weighs 2.9 pounds and comes with a UL listing.

The Eaton’s F-Frame circuit breakers are HACR rated and all the circuit breakers that are 10 to 30 Amps circuit breakers are suitable for high-intensity discharge use. These F-Frame circuit breakers are also suitable for reverse use. The line and load terminal circuit breakers provide a wire connection capability for the circuit breakers. The F-Frame circuit breakers also feature load terminals that are standard for the equipment. Note that the circuit breakers that feature DC ratings apply to the substantially non-inductive circuits. The circuit breaker should also be installed by a trained technician.

Repairs
Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your ED2020. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your ED2020. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

PDF