GHB2090
Warranty: | 1 year DO Supply Warranty Included |
Shipping: | Worldwide shipping via DHL, UPS, Fedex, and TNT |
Repairs: | We offer repair service for the GHB2090. |
Exchange: | Exchange credit for your defective unit available. |
Part Number/Catalog No. | GHB2090 |
Product Type | Molded Case Circuit Breaker |
Series | C |
Frame | G |
Type | Bolt-On Panelboard |
Pole(s) | 2 |
Trip Amps | 90 |
Dimensions | 4 x 3 x 2.63 inches |
Part Number/Catalog No. | GHB2090 |
Product Type | Molded Case Circuit Breaker |
Series | C |
Frame | G |
Type | Bolt-On Panelboard |
Pole(s) | 2 |
Trip Amps | 90 |
Dimensions | 4 x 3 x 2.63 inches |
The GHB2090 circuit breaker is a Series C circuit breakers having a G Frame. These circuit breakers are made to be installed and operated in an environment where the ambient temperature is between 0 and 40 degrees Celsius. Users must make sure that the input current rating of the line conductor should be less than 90 Amps because the circuit breaker has a maximum current rating of 90 Amps. The circuit breaker has 2 poles and it also has a window which indicates the status of the circuit breaker. If the circuit breaker is in the tripped position, it will turn white. The users must perform the necessary functional and inspection tests for the safety of the users and to ensure efficient operation. If users find the circuit breaker is overheating or the contacts are not getting linked and are disconnecting the line and the load terminals during testing, the users must replace the GHB2090.
While performing the GHB2090 installation, it is recommended that the users follow the instructions in the manual and comply with the safety norms to prevent any injury or damage. Also, the users must ensure the power supply on the line terminals is turned off and that there is no voltage present on the system bus to avoid electric shock. While performing the installation of the GHB2090, the switch must be in the off position to prevent an accidental turn-on of the system. Make sure the line and load terminals are connected securely and that there are no exposed wires. The users can contact the manufacturer support team if they need any further assistance.
Type | Lead Time | Price | Action |
---|---|---|---|
Repair Service | 2-4 weeks | Ask | ![]() |
Our highly skilled technicians can repair your GHB2090. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.
Size | |
Input Type | |
Panel Cutout Height | in mm |
Panel Cutout Width | in mm |
Terminal Height | in mm |
Terminal Width | in mm |
Terminal Overall Depth | in mm |
Terminal Mounted Depth | in mm |
Part Number/Catalog No. | GHB2090 |
Product Type | Molded Case Circuit Breaker |
Series | C |
Frame | G |
Type | Bolt-On Panelboard |
Pole(s) | 2 |
Trip Amps | 90 |
Dimensions | 4 x 3 x 2.63 inches |
Part Number/Catalog No. | GHB2090 |
Product Type | Molded Case Circuit Breaker |
Series | C |
Frame | G |
Type | Bolt-On Panelboard |
Pole(s) | 2 |
Trip Amps | 90 |
Dimensions | 4 x 3 x 2.63 inches |
The GHB2090 circuit breaker is a Series C circuit breakers having a G Frame. These circuit breakers are made to be installed and operated in an environment where the ambient temperature is between 0 and 40 degrees Celsius. Users must make sure that the input current rating of the line conductor should be less than 90 Amps because the circuit breaker has a maximum current rating of 90 Amps. The circuit breaker has 2 poles and it also has a window which indicates the status of the circuit breaker. If the circuit breaker is in the tripped position, it will turn white. The users must perform the necessary functional and inspection tests for the safety of the users and to ensure efficient operation. If users find the circuit breaker is overheating or the contacts are not getting linked and are disconnecting the line and the load terminals during testing, the users must replace the GHB2090.
While performing the GHB2090 installation, it is recommended that the users follow the instructions in the manual and comply with the safety norms to prevent any injury or damage. Also, the users must ensure the power supply on the line terminals is turned off and that there is no voltage present on the system bus to avoid electric shock. While performing the installation of the GHB2090, the switch must be in the off position to prevent an accidental turn-on of the system. Make sure the line and load terminals are connected securely and that there are no exposed wires. The users can contact the manufacturer support team if they need any further assistance.
Type | Lead Time | Price | Action |
---|---|---|---|
Repair Service | 2-4 weeks | Ask | ![]() |
Our highly skilled technicians can repair your GHB2090. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.
Type | Lead Time | Price | Action |
---|---|---|---|
Repair Service | 2-4 weeks | Ask | ![]() |
Our highly skilled technicians can repair your GHB2090. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.