GHB2090

GHB2090

Description: The Eaton GHB2090 Bolt-On Panelboard Molded Case Circuit Breaker operates with 2 Pole(s) and 90 Trip Amps. The module has a G-Frame and 4 x 3 x 2.63 in. Dimensions (H x W x D).
Rated 4.6 with 10 reviews
top legal disclaimer
top legal disclaimer

credit cards accepted
better business bureau

Available Now

Submit RFQ for GHB2090

Add more parts to quote

Description: The Eaton GHB2090 Bolt-On Panelboard Molded Case Circuit Breaker operates with 2 Pole(s) and 90 Trip Amps. The module has a G-Frame and 4 x 3 x 2.63 in. Dimensions (H x W x D).

Warranty: 1 year DO Supply Warranty Included
Shipping: Worldwide shipping via DHL, UPS, Fedex, and TNT
Repairs: We offer repair service for the GHB2090.
Exchange: Exchange credit for your defective unit available.

To Speak to a sales representative for pricing & lead time:

phone

International
919-205-4392

Rated 4.6 with 10 reviews

    Technical Specifications for GHB2090

Part Number/Catalog No.GHB2090
Product TypeMolded Case Circuit Breaker
SeriesC
FrameG
TypeBolt-On Panelboard
Pole(s)2
Trip Amps90
Dimensions4 x 3 x 2.63 inches
Part Number/Catalog No.GHB2090
Product TypeMolded Case Circuit Breaker
SeriesC
FrameG
TypeBolt-On Panelboard
Pole(s)2
Trip Amps90
Dimensions4 x 3 x 2.63 inches
s

About GHB2090

The GHB2090 circuit breaker is a Series C circuit breakers having a G Frame. These circuit breakers are made to be installed and operated in an environment where the ambient temperature is between 0 and 40 degrees Celsius. Users must make sure that the input current rating of the line conductor should be less than 90 Amps because the circuit breaker has a maximum current rating of 90 Amps. The circuit breaker has 2 poles and it also has a window which indicates the status of the circuit breaker. If the circuit breaker is in the tripped position, it will turn white. The users must perform the necessary functional and inspection tests for the safety of the users and to ensure efficient operation. If users find the circuit breaker is overheating or the contacts are not getting linked and are disconnecting the line and the load terminals during testing, the users must replace the GHB2090.

While performing the GHB2090 installation, it is recommended that the users follow the instructions in the manual and comply with the safety norms to prevent any injury or damage. Also, the users must ensure the power supply on the line terminals is turned off and that there is no voltage present on the system bus to avoid electric shock. While performing the installation of the GHB2090, the switch must be in the off position to prevent an accidental turn-on of the system. Make sure the line and load terminals are connected securely and that there are no exposed wires. The users can contact the manufacturer support team if they need any further assistance.

Repair Services for GHB2090

Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your GHB2090. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Dimensions For GHB2090

Size
Input Type
Panel Cutout Height in mm
Panel Cutout Width in mm
Terminal Height in mm
Terminal Width in mm
Terminal Overall Depth in mm
Terminal Mounted Depth in mm

Dimensions For GHB2090

Resolutions For GHB2090

Technical Specifications
Part Number/Catalog No.GHB2090
Product TypeMolded Case Circuit Breaker
SeriesC
FrameG
TypeBolt-On Panelboard
Pole(s)2
Trip Amps90
Dimensions4 x 3 x 2.63 inches
Part Number/Catalog No.GHB2090
Product TypeMolded Case Circuit Breaker
SeriesC
FrameG
TypeBolt-On Panelboard
Pole(s)2
Trip Amps90
Dimensions4 x 3 x 2.63 inches
About

The GHB2090 circuit breaker is a Series C circuit breakers having a G Frame. These circuit breakers are made to be installed and operated in an environment where the ambient temperature is between 0 and 40 degrees Celsius. Users must make sure that the input current rating of the line conductor should be less than 90 Amps because the circuit breaker has a maximum current rating of 90 Amps. The circuit breaker has 2 poles and it also has a window which indicates the status of the circuit breaker. If the circuit breaker is in the tripped position, it will turn white. The users must perform the necessary functional and inspection tests for the safety of the users and to ensure efficient operation. If users find the circuit breaker is overheating or the contacts are not getting linked and are disconnecting the line and the load terminals during testing, the users must replace the GHB2090.

While performing the GHB2090 installation, it is recommended that the users follow the instructions in the manual and comply with the safety norms to prevent any injury or damage. Also, the users must ensure the power supply on the line terminals is turned off and that there is no voltage present on the system bus to avoid electric shock. While performing the installation of the GHB2090, the switch must be in the off position to prevent an accidental turn-on of the system. Make sure the line and load terminals are connected securely and that there are no exposed wires. The users can contact the manufacturer support team if they need any further assistance.

Repairs
Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your GHB2090. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your GHB2090. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

PDF