KD4200

KD4200

Description: The KD4200 Molded Case Circuit Breaker operates with 4 Poles and 200 Amps. The Thermal-Magnetic Molded Case Circuit Breaker is in the C Series and has a 11.5 lbs Weight.
Rated 4.6 with 8 reviews
top legal disclaimer
top legal disclaimer

credit cards accepted
better business bureau

Available Now

Submit RFQ for KD4200

Add more parts to quote

Description: The KD4200 Molded Case Circuit Breaker operates with 4 Poles and 200 Amps. The Thermal-Magnetic Molded Case Circuit Breaker is in the C Series and has a 11.5 lbs Weight.

Warranty: 1 year DO Supply Warranty Included
Shipping: Worldwide shipping via DHL, UPS, Fedex, and TNT
Repairs: We offer repair service for the KD4200.
Exchange: Exchange credit for your defective unit available.

To speak to a sales representative for pricing & lead time:


Rated 4.6 with 8 reviews

    Technical Specifications for KD4200

Part Number/Catalog No.KD4200
Product TypeMolded Case Circuit Breaker
SeriesC
FrameK
Poles4
ListingThis specification list has been compiled by DO Supply.
Amps200 Amps
Unit TypeThermal-Magnetic
Interrupting Capacity65 kA at 240 Volts AC
Dimensions (W x H x D)7.22 x 10.13 x 4.1 inches
Weight11.5 pounds
Part Number/Catalog No.KD4200
Product TypeMolded Case Circuit Breaker
SeriesC
FrameK
Poles4
Amps200 Amps
Unit TypeThermal-Magnetic
Interrupting Capacity65 kA at 240 Volts AC
Dimensions (W x H x D)7.22 x 10.13 x 4.1 inches
Weight11.5 pounds
s

About KD4200

The Westinghouse/Cutler-Hammer/Eaton KD4200 is a molded case circuit breaker with an interchangeable trip unit. The KD4200 circuit breaker is part of the Series C molded case circuit breakers product line made by the Eaton company. The KD4200 has a K-frame for protection and it is UL and CSA approved. The interrupt ratings for the circuit breaker, as with other K-frame molded case circuit breakers, are capped at 40 kAIC at 415 Volts AC, 10 kAIC at 250 Volts DC, and at 65 kAIC at 240 Volts AC. These interrupt ratings are defined by the International Electrotechnical Commission (IEC 157-1) standards.



The Westinghouse/Cutler-Hammer/Eaton KD4200 circuit breaker has 4 poles and it can be used in electrical circuits that do not exceed an operating current of 200 Amps. Additionally, the protected circuits should not exceed a voltage of 600 Volts AC or 250 Volts DC in alternating current or direct current powered systems/circuits, respectively. The KD4200 circuit breaker does not have a neutral pole and it does not provide neutral protection. The circuit breaker uses a thermal magnetic trip mechanism. The trip unit used by the KD4200 circuit breaker is user-replaceable, provided the breaker was user-assembled. When used to provide protection to 250 Volts DC-powered systems, the KD4200 molded case circuit breaker has a minimum time constant of 8 milliseconds at a current rating of 22 kiloAmps. Note that the KD4200 can be factory-assembled. For the terminals, the circuit breaker has load and line side lug terminals.



Repair Services for KD4200

Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your KD4200. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Dimensions For KD4200

Size
Input Type
Panel Cutout Height in mm
Panel Cutout Width in mm
Terminal Height in mm
Terminal Width in mm
Terminal Overall Depth in mm
Terminal Mounted Depth in mm

Dimensions For KD4200

Resolutions For KD4200

About

Technical Specifications for KD4200

Part Number/Catalog No.KD4200
Product TypeMolded Case Circuit Breaker
SeriesC
FrameK
Poles4
Amps200 Amps
Unit TypeThermal-Magnetic
Interrupting Capacity65 kA at 240 Volts AC
Dimensions (W x H x D)7.22 x 10.13 x 4.1 inches
Weight11.5 pounds
Part Number/Catalog No.KD4200
Product TypeMolded Case Circuit Breaker
SeriesC
FrameK
Poles4
Amps200 Amps
Unit TypeThermal-Magnetic
Interrupting Capacity65 kA at 240 Volts AC
Dimensions (W x H x D)7.22 x 10.13 x 4.1 inches
Weight11.5 pounds

About KD4200

The Westinghouse/Cutler-Hammer/Eaton KD4200 is a molded case circuit breaker with an interchangeable trip unit. The KD4200 circuit breaker is part of the Series C molded case circuit breakers product line made by the Eaton company. The KD4200 has a K-frame for protection and it is UL and CSA approved. The interrupt ratings for the circuit breaker, as with other K-frame molded case circuit breakers, are capped at 40 kAIC at 415 Volts AC, 10 kAIC at 250 Volts DC, and at 65 kAIC at 240 Volts AC. These interrupt ratings are defined by the International Electrotechnical Commission (IEC 157-1) standards.



The Westinghouse/Cutler-Hammer/Eaton KD4200 circuit breaker has 4 poles and it can be used in electrical circuits that do not exceed an operating current of 200 Amps. Additionally, the protected circuits should not exceed a voltage of 600 Volts AC or 250 Volts DC in alternating current or direct current powered systems/circuits, respectively. The KD4200 circuit breaker does not have a neutral pole and it does not provide neutral protection. The circuit breaker uses a thermal magnetic trip mechanism. The trip unit used by the KD4200 circuit breaker is user-replaceable, provided the breaker was user-assembled. When used to provide protection to 250 Volts DC-powered systems, the KD4200 molded case circuit breaker has a minimum time constant of 8 milliseconds at a current rating of 22 kiloAmps. Note that the KD4200 can be factory-assembled. For the terminals, the circuit breaker has load and line side lug terminals.



Repairs
Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your KD4200. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your KD4200. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

PDF