KT2225T

KT2225T

Description: The KT2225T Trip Unit operates with 2 Poles and 225 Amps. The Thermal-Magnetic Trip Unit is in the C Series and has a 1.5 lbs Weight.
Rated 4.9 with 5 reviews
top legal disclaimer
top legal disclaimer

credit cards accepted
better business bureau

Available Now

Submit RFQ for KT2225T

Add more parts to quote

Description: The KT2225T Trip Unit operates with 2 Poles and 225 Amps. The Thermal-Magnetic Trip Unit is in the C Series and has a 1.5 lbs Weight.

Warranty: 1 year DO Supply Warranty Included
Shipping: Worldwide shipping via DHL, UPS, Fedex, and TNT
Repairs: We offer repair service for the KT2225T.
Exchange: Exchange credit for your defective unit available.

To speak to a sales representative for pricing & lead time:


Rated 4.9 with 5 reviews

    Technical Specifications for KT2225T

Part Number/Catalog No.KT2225T
Product TypeTrip Unit
SeriesC
FrameK
Poles2
Amps225
Unit TypeThermal-Magnetic
Continuous Current Range55 to 400 Amps
Dimensions (W x H x D)5.5 x 10.13 x 4.1 inches
Weight1.5 pounds
Part Number/Catalog No.KT2225T
Product TypeTrip Unit
SeriesC
FrameK
Poles2
Amps225
Unit TypeThermal-Magnetic
Continuous Current Range55 to 400 Amps
Dimensions (W x H x D)5.5 x 10.13 x 4.1 inches
Weight1.5 pounds
s

About KT2225T

The Eaton Cutler-Hammer KT2225T is a trip unit with 2 poles that can be installed in C Series molded case circuit breakers with K Frames. It is applicable for 225 Amps rated systems and it satisfies the UL-489 standard requirements. The Eaton KT2225T is an interchangeable trip unit that has a thermal element with the time delay on the overload and an adjustable magnetic trip that offers protection against short circuits. The KT2225T trip unit is calibrated at 40 degrees Celsius and its housing is factory sealed to disable the tampering option. This calibrated nominal device current that the trip unit can carry continuously is marked on the nameplate of the trip unit. Note that according to the NEC requirements, protective devices like molded case circuit breakers should not be loaded with more than 80% of the nominal current rating.



The users should not connect cables to the MCCB or supply it with the power until they install the KT2225T into it. Inspect the trip unit for visible signs of damage before integrating it with the circuit breaker frame. On the load side of the frame, remove the plastic protective covers and push the trip unit upwards until the trip unit is correctly seated in the base. Check the latch bracket pin. It should be properly placed in its slots. To position the trip unit easily, the users can push the circuit breaker lever to the closed position. To finish the installation process, use a hexagonal-head wrench to screw in and tighten the retaining screws of the trip unit (the screws on both poles). Put protective plastic barriers on the trip unit.



Repair Services for KT2225T

Type Lead Time Price Action
Repair Service 2-4 weeks $581.4cartAdd to Cart

Our highly skilled technicians can repair your KT2225T. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Dimensions For KT2225T

Size
Input Type
Panel Cutout Height in mm
Panel Cutout Width in mm
Terminal Height in mm
Terminal Width in mm
Terminal Overall Depth in mm
Terminal Mounted Depth in mm

Dimensions For KT2225T

Resolutions For KT2225T

About

Technical Specifications for KT2225T

Part Number/Catalog No.KT2225T
Product TypeTrip Unit
SeriesC
FrameK
Poles2
Amps225
Unit TypeThermal-Magnetic
Continuous Current Range55 to 400 Amps
Dimensions (W x H x D)5.5 x 10.13 x 4.1 inches
Weight1.5 pounds
Part Number/Catalog No.KT2225T
Product TypeTrip Unit
SeriesC
FrameK
Poles2
Amps225
Unit TypeThermal-Magnetic
Continuous Current Range55 to 400 Amps
Dimensions (W x H x D)5.5 x 10.13 x 4.1 inches
Weight1.5 pounds

About KT2225T

The Eaton Cutler-Hammer KT2225T is a trip unit with 2 poles that can be installed in C Series molded case circuit breakers with K Frames. It is applicable for 225 Amps rated systems and it satisfies the UL-489 standard requirements. The Eaton KT2225T is an interchangeable trip unit that has a thermal element with the time delay on the overload and an adjustable magnetic trip that offers protection against short circuits. The KT2225T trip unit is calibrated at 40 degrees Celsius and its housing is factory sealed to disable the tampering option. This calibrated nominal device current that the trip unit can carry continuously is marked on the nameplate of the trip unit. Note that according to the NEC requirements, protective devices like molded case circuit breakers should not be loaded with more than 80% of the nominal current rating.



The users should not connect cables to the MCCB or supply it with the power until they install the KT2225T into it. Inspect the trip unit for visible signs of damage before integrating it with the circuit breaker frame. On the load side of the frame, remove the plastic protective covers and push the trip unit upwards until the trip unit is correctly seated in the base. Check the latch bracket pin. It should be properly placed in its slots. To position the trip unit easily, the users can push the circuit breaker lever to the closed position. To finish the installation process, use a hexagonal-head wrench to screw in and tighten the retaining screws of the trip unit (the screws on both poles). Put protective plastic barriers on the trip unit.



Repairs
Type Lead Time Price Action
Repair Service 2-4 weeks $581.4cartAdd to Cart

Our highly skilled technicians can repair your KT2225T. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Type Lead Time Price Action
Repair Service 2-4 weeks $581.4cartAdd to Cart

Our highly skilled technicians can repair your KT2225T. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.