LDB2600

LDB2600

Description: The Eaton LDB2600 Molded Case Circuit Breaker operates with 2 Poles and 600 Amps. The module has a L Frame and a Thermal-Magnetic Unit Type.
Rated 4.9 with 7 reviews
top legal disclaimer
top legal disclaimer

credit cards accepted
better business bureau

Call

Submit RFQ for LDB2600

Add more parts to quote

Description: The Eaton LDB2600 Molded Case Circuit Breaker operates with 2 Poles and 600 Amps. The module has a L Frame and a Thermal-Magnetic Unit Type.

Warranty: 1 year DO Supply Warranty Included
Shipping: Worldwide shipping via DHL, UPS, Fedex, and TNT
Repairs: We offer repair service for the LDB2600.
Exchange: Exchange credit for your defective unit available.

To speak to a sales representative for pricing & lead time:


Rated 4.9 with 7 reviews

    Technical Specifications for LDB2600

Part Number/Catalog No.LDB2600
Product TypeMolded Case Circuit Breaker
SeriesC
FrameL
Poles2
Amps600 Amps
Interrupting Capacity65 kAIC at 240 Volts AC
Unit TypeThermal-Magnetic
Dimensions (W x H x D)8.25 x 10.75 x 4.06 inches
Weight18 pounds
Part Number/Catalog No.LDB2600
Product TypeMolded Case Circuit Breaker
SeriesC
FrameL
Poles2
Amps600 Amps
Interrupting Capacity65 kAIC at 240 Volts AC
Unit TypeThermal-Magnetic
Dimensions (W x H x D)8.25 x 10.75 x 4.06 inches
Weight18 pounds
s

About LDB2600

The LDB2600 Molded Case Circuit Breaker by Eaton Cutler-Hammer is a completely factory assembled circuit in the Frame L series of multipurpose circuit breakers with non-interchangeable thermal-magnetic trip units, and it is used for short-circuit and overload protection. This device is used in most low-voltage distribution systems, protecting conductors, motors, motor starters, and connected devices, and it is assembled with load and line side terminals for easy field wiring. The LDB2600 is a 600 Amps rated circuit breaker, with 35 KAIC of maximum interrupt rating at 480 Volts AC, and is designed for 250 Volts DC or 600 Volts AC grounded and ungrounded systems. It has copper/aluminum conductors supplied as standard terminals (2TA603LDK), with an average wire size of 185 by 240 millimeters square, and is UL and CSA rated to meet the nominal current requirements.



The LDB2600 has a thermal-magnetic trip unit that is closed to further adjustments, and which provides thermal and magnetic trip actions. It uses a bimetal strip heated by a load current, and which deflects on prolonged overloads for thermal trip action, and it uses an electromagnet in series with the current load for instantaneous magnetic trip action. A trip-free, quick make/break operating mechanism is designed so that the contacts cannot be held closed against an abnormal circuit condition and it is used to open and close the breaker’s contacts, and also to indicate whether the circuit breaker is tripped, off, or on. The LDB2600 has an operating temperature limit of 40 degrees Celsius, and a maximum operating altitude of 6000 feet without de-rating. It weighs approximately 8.2 kilograms (including the terminals), and it has total shipping dimensions of 209.6 x 273.1 x 103.1 millimeters.



Repair Services for LDB2600

Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your LDB2600. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Dimensions For LDB2600

Size
Input Type
Panel Cutout Height in mm
Panel Cutout Width in mm
Terminal Height in mm
Terminal Width in mm
Terminal Overall Depth in mm
Terminal Mounted Depth in mm

Dimensions For LDB2600

Resolutions For LDB2600

About

Technical Specifications for LDB2600

Part Number/Catalog No.LDB2600
Product TypeMolded Case Circuit Breaker
SeriesC
FrameL
Poles2
Amps600 Amps
Interrupting Capacity65 kAIC at 240 Volts AC
Unit TypeThermal-Magnetic
Dimensions (W x H x D)8.25 x 10.75 x 4.06 inches
Weight18 pounds
Part Number/Catalog No.LDB2600
Product TypeMolded Case Circuit Breaker
SeriesC
FrameL
Poles2
Amps600 Amps
Interrupting Capacity65 kAIC at 240 Volts AC
Unit TypeThermal-Magnetic
Dimensions (W x H x D)8.25 x 10.75 x 4.06 inches
Weight18 pounds

About LDB2600

The LDB2600 Molded Case Circuit Breaker by Eaton Cutler-Hammer is a completely factory assembled circuit in the Frame L series of multipurpose circuit breakers with non-interchangeable thermal-magnetic trip units, and it is used for short-circuit and overload protection. This device is used in most low-voltage distribution systems, protecting conductors, motors, motor starters, and connected devices, and it is assembled with load and line side terminals for easy field wiring. The LDB2600 is a 600 Amps rated circuit breaker, with 35 KAIC of maximum interrupt rating at 480 Volts AC, and is designed for 250 Volts DC or 600 Volts AC grounded and ungrounded systems. It has copper/aluminum conductors supplied as standard terminals (2TA603LDK), with an average wire size of 185 by 240 millimeters square, and is UL and CSA rated to meet the nominal current requirements.



The LDB2600 has a thermal-magnetic trip unit that is closed to further adjustments, and which provides thermal and magnetic trip actions. It uses a bimetal strip heated by a load current, and which deflects on prolonged overloads for thermal trip action, and it uses an electromagnet in series with the current load for instantaneous magnetic trip action. A trip-free, quick make/break operating mechanism is designed so that the contacts cannot be held closed against an abnormal circuit condition and it is used to open and close the breaker’s contacts, and also to indicate whether the circuit breaker is tripped, off, or on. The LDB2600 has an operating temperature limit of 40 degrees Celsius, and a maximum operating altitude of 6000 feet without de-rating. It weighs approximately 8.2 kilograms (including the terminals), and it has total shipping dimensions of 209.6 x 273.1 x 103.1 millimeters.



Repairs
Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your LDB2600. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your LDB2600. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

PDF