LT2500T

LT2500T

Description: The Eaton LT2500T is an LT type electronic molded case trip unit for the L-frame Series C circuit breakers. The LT2500T has a 500 Amps current rating. It is a 2-pole device with a fixed thermal and magnetic tripping module. The magnetic trip current range is 2500 to 5000 Amps. read more...
Rated 5 with 6 reviews
top legal disclaimer
top legal disclaimer

credit cards accepted
better business bureau

Available Now

Submit RFQ for LT2500T

Add more parts to quote

Description: The Eaton LT2500T is an LT type electronic molded case trip unit for the L-frame Series C circuit breakers. The LT2500T has a 500 Amps current rating. It is a 2-pole device with a fixed thermal and magnetic tripping module. The magnetic trip current range is 2500 to 5000 Amps. read more...

Warranty: 1 year DO Supply Warranty Included
Shipping: Worldwide shipping via DHL, UPS, Fedex, and TNT
Repairs: We offer repair service for the LT2500T.
Exchange: Exchange credit for your defective unit available.

To speak to a sales representative for pricing & lead time:


Rated 5 with 6 reviews

    Technical Specifications for LT2500T

Part Number/Catalog No.LT2500T
Product TypeTrip Unit
SeriesC
FrameL
Poles2
Amps500 Amps
Interrupting FramesStandard, High, or Ultra High
Unit TypeThermal-Magnetic
Dimensions (W x H x D)8.25 x 10.75 x 4.06 inches
Weight3 pounds
Part Number/Catalog No.LT2500T
Product TypeTrip Unit
SeriesC
FrameL
Poles2
Amps500 Amps
Interrupting FramesStandard, High, or Ultra High
Unit TypeThermal-Magnetic
Dimensions (W x H x D)8.25 x 10.75 x 4.06 inches
Weight3 pounds
s

About LT2500T

The Eaton LT2500T is an LT type electronic molded case trip unit for the L-frame Series C circuit breakers. The LT2500T has a 500 Amps current rating. It is a 2-pole device with a fixed thermal and magnetic tripping module. The magnetic trip current range is 2500 to 5000 Amps. The circuit breaker is tripped within 2 hours by a thermal element in the event of a 135% overload and it is tripped in less time for higher overloads. The circuit breaker is tripped by the magnetic element for all the currents that exceed the magnetic setting. The LT2500T is calibrated at 40 degrees Celsius and 50 to 60 Hertz frequency. The cover of the trip unit is sealed at the factory to prevent possible tampering with the calibration. The manufacturer should be consulted regarding the de-rating of the device in other ambient conditions and at other frequencies.

 

The installation and the maintenance procedures of the LT2500T should only be undertaken when it is powered off. Failure to do switch the power off could lead to substantial equipment damage, and to serious injury and even death to the users. In addition to ensuring that no voltage is present during installation or maintenance, all general and local safety laws and protocols should be followed. During the installation of the LT2500T in a circuit breaker, the breaker should be in the off or the tripped state. Several accessories are available for the L-frame LT2500T, including a shunt trip, low energy shunt trip, alarm or lockout switch, undervoltage release mechanism, and an auxiliary switch. it is recommended to install the internal accessories before mounting and connecting the circuit breaker.



Technical Description of LT2500T

The Eaton LT2500T Trip Unit operates with 2 Poles and 500 Amps. The module has a L Frame and a Thermal-Magnetic Unit Type.

Repair Services for LT2500T

Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your LT2500T. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Dimensions For LT2500T

Size
Input Type
Panel Cutout Height in mm
Panel Cutout Width in mm
Terminal Height in mm
Terminal Width in mm
Terminal Overall Depth in mm
Terminal Mounted Depth in mm

Dimensions For LT2500T

Resolutions For LT2500T

About

Technical Specifications for LT2500T

Part Number/Catalog No.LT2500T
Product TypeTrip Unit
SeriesC
FrameL
Poles2
Amps500 Amps
Interrupting FramesStandard, High, or Ultra High
Unit TypeThermal-Magnetic
Dimensions (W x H x D)8.25 x 10.75 x 4.06 inches
Weight3 pounds
Part Number/Catalog No.LT2500T
Product TypeTrip Unit
SeriesC
FrameL
Poles2
Amps500 Amps
Interrupting FramesStandard, High, or Ultra High
Unit TypeThermal-Magnetic
Dimensions (W x H x D)8.25 x 10.75 x 4.06 inches
Weight3 pounds

About LT2500T

The Eaton LT2500T is an LT type electronic molded case trip unit for the L-frame Series C circuit breakers. The LT2500T has a 500 Amps current rating. It is a 2-pole device with a fixed thermal and magnetic tripping module. The magnetic trip current range is 2500 to 5000 Amps. The circuit breaker is tripped within 2 hours by a thermal element in the event of a 135% overload and it is tripped in less time for higher overloads. The circuit breaker is tripped by the magnetic element for all the currents that exceed the magnetic setting. The LT2500T is calibrated at 40 degrees Celsius and 50 to 60 Hertz frequency. The cover of the trip unit is sealed at the factory to prevent possible tampering with the calibration. The manufacturer should be consulted regarding the de-rating of the device in other ambient conditions and at other frequencies.

 

The installation and the maintenance procedures of the LT2500T should only be undertaken when it is powered off. Failure to do switch the power off could lead to substantial equipment damage, and to serious injury and even death to the users. In addition to ensuring that no voltage is present during installation or maintenance, all general and local safety laws and protocols should be followed. During the installation of the LT2500T in a circuit breaker, the breaker should be in the off or the tripped state. Several accessories are available for the L-frame LT2500T, including a shunt trip, low energy shunt trip, alarm or lockout switch, undervoltage release mechanism, and an auxiliary switch. it is recommended to install the internal accessories before mounting and connecting the circuit breaker.



Technical Description of LT2500T

The Eaton LT2500T Trip Unit operates with 2 Poles and 500 Amps. The module has a L Frame and a Thermal-Magnetic Unit Type.
Repairs
Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your LT2500T. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your LT2500T. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

PDF