TA602LD

TA602LD

Description: The Eaton TA602LD Standard Terminal operates with 2 Poles and 300-500 Amps. The module has a L Frame and a Standard Unit Type.
Rated 4.5 with 20 reviews

top legal disclaimer bottom legal disclaimer
credit cards accepted
better business bureau

Available Now

Submit RFQ for TA602LD

Add more parts to quote

Description: The Eaton TA602LD Standard Terminal operates with 2 Poles and 300-500 Amps. The module has a L Frame and a Standard Unit Type.

Warranty: 1 year DO Supply Warranty Included
Shipping: Worldwide shipping via DHL, UPS, Fedex, and TNT
Repairs: We offer repair service for the TA602LD.
Exchange: Exchange credit for your defective unit available.

To Speak to a sales representative for pricing & lead time:

phone

International
919-205-4392

Rated 4.5 with 20 reviews

    Technical Specifications for TA602LD

Part Number/Catalog No.TA602LD
Product TypeStandard Terminal
SeriesC
FrameL
Poles2
Amps300-500
Interrupting Capacity65 kA @ 240V AC
Unit TypeStandard
Dimensions (W x H x D)8.25 x 10.75 x 4.06 in.
Weight18 lbs
Part Number/Catalog No.TA602LD
Product TypeStandard Terminal
SeriesC
FrameL
Poles2
Amps300-500
Interrupting Capacity65 kA @ 240V AC
Unit TypeStandard
Dimensions (W x H x D)8.25 x 10.75 x 4.06 in.
Weight18 lbs

About TA602LD

The TA602LD by Cutler-Hammer (a division of the Eaton Corporation) is a lug kit for molded case circuit breakers. This kit may come as a preassembled part of the L frame molded case circuit breaker which is a part of the power distribution protective equipment systems. It can also be a spare part for defective lug replacement. This part is individually packed. The TA602LD is a spare part for 1 pole of the MCCB, so users will need 2, 3, or 4 of them for 2-pole, 3-pole, or 4-pole L frame circuit breakers. In this kit, users will find one lug block, 2 screws, and 2 washers. The Cutler-Hammer TA602LD can be installed in LD, HLD, HLDDC, HLDB, LDCB, CHLD, CLDC, LDC, LES, CLD, HLW, and LW frame MCCBs.

The TA602LD kit is suitable only for C Series Eaton molded case circuit breakers. This lug terminal kit accepts wires of A 3/0 AWG size. It has 2 barrels. The material that it is made of is aluminum. The MCM size of the kit is 350. It can be used for currents of up to 500 Amps. The Eaton TA602LD has dimensions of 1.7 inches x 1.9 inches x 2.5 inches (43.2 millimeters x 48.3 millimeters x 63.5 millimeters). Its net weight is approximated at 3.2 pounds (1.45 kilograms). To install the TA602LD on the MCCB, users must remove the terminal cover. Below the cover, users will find 2, 3, or 4 seats for the lug kit (depending on the MCCB users are using). Position all the lug kits into seats and fix them tightly. When this process is finished, return the terminal cover to its initial position.

Repair Services for TA602LD

Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your TA602LD. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Dimension For TA602LD

Size
Input Type
Panel Cutout Height in mm
Panel Cutout Width in mm
Terminal Height in mm
Terminal Width in mm
Terminal Overall Depth in mm
Terminal Mounted Depth in mm

Dimension For TA602LD

Technical Specifications
Part Number/Catalog No.TA602LD
Product TypeStandard Terminal
SeriesC
FrameL
Poles2
Amps300-500
Interrupting Capacity65 kA @ 240V AC
Unit TypeStandard
Dimensions (W x H x D)8.25 x 10.75 x 4.06 in.
Weight18 lbs
Part Number/Catalog No.TA602LD
Product TypeStandard Terminal
SeriesC
FrameL
Poles2
Amps300-500
Interrupting Capacity65 kA @ 240V AC
Unit TypeStandard
Dimensions (W x H x D)8.25 x 10.75 x 4.06 in.
Weight18 lbs
About

The TA602LD by Cutler-Hammer (a division of the Eaton Corporation) is a lug kit for molded case circuit breakers. This kit may come as a preassembled part of the L frame molded case circuit breaker which is a part of the power distribution protective equipment systems. It can also be a spare part for defective lug replacement. This part is individually packed. The TA602LD is a spare part for 1 pole of the MCCB, so users will need 2, 3, or 4 of them for 2-pole, 3-pole, or 4-pole L frame circuit breakers. In this kit, users will find one lug block, 2 screws, and 2 washers. The Cutler-Hammer TA602LD can be installed in LD, HLD, HLDDC, HLDB, LDCB, CHLD, CLDC, LDC, LES, CLD, HLW, and LW frame MCCBs.

The TA602LD kit is suitable only for C Series Eaton molded case circuit breakers. This lug terminal kit accepts wires of A 3/0 AWG size. It has 2 barrels. The material that it is made of is aluminum. The MCM size of the kit is 350. It can be used for currents of up to 500 Amps. The Eaton TA602LD has dimensions of 1.7 inches x 1.9 inches x 2.5 inches (43.2 millimeters x 48.3 millimeters x 63.5 millimeters). Its net weight is approximated at 3.2 pounds (1.45 kilograms). To install the TA602LD on the MCCB, users must remove the terminal cover. Below the cover, users will find 2, 3, or 4 seats for the lug kit (depending on the MCCB users are using). Position all the lug kits into seats and fix them tightly. When this process is finished, return the terminal cover to its initial position.

Repairs
Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your TA602LD. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your TA602LD. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

PDF