HMDLB3800

HMDLB3800

Description: The Eaton HMDLB3800 Molded Case Circuit Breaker operates with 3 Poles and 800 Amps. It also has a F Frame and a 310+ Unit Type.
Rated 4.7 with 12 reviews
top legal disclaimer
top legal disclaimer

credit cards accepted
better business bureau

Available Now

Submit RFQ for HMDLB3800

Add more parts to quote

Description: The Eaton HMDLB3800 Molded Case Circuit Breaker operates with 3 Poles and 800 Amps. It also has a F Frame and a 310+ Unit Type.

Warranty: 1 year DO Supply Warranty Included
Shipping: Worldwide shipping via DHL, UPS, Fedex, and TNT
Repairs: We offer repair service for the HMDLB3800.
Exchange: Exchange credit for your defective unit available.

To speak to a sales representative for pricing & lead time:

phone

International
919-205-4392
phone

International
919-205-4392

Rated 4.7 with 12 reviews

    Technical Specifications for HMDLB3800

Part Number/Catalog No.HMDLB3800
Product TypeMolded Case Circuit Breaker
SeriesC
FrameF
Poles3
Amps800 Amps
Interrupting Capacity100 kAIC at 240 Volts AC
Unit Type310+
Dimensions (W x H x D)8.25 x 16 x 4.06 inches
Weight30 pounds
Part Number/Catalog No.HMDLB3800
Product TypeMolded Case Circuit Breaker
SeriesC
FrameF
Poles3
Amps800 Amps
Interrupting Capacity100 kAIC at 240 Volts AC
Unit Type310+
Dimensions (W x H x D)8.25 x 16 x 4.06 inches
Weight30 pounds

About HMDLB3800

The Eaton Cutler-Hammer HMDLB3800 is a circuit breaker with a fixed thermal and a fixed magnetic trip unit. The circuit breaker uses the TA800MA2 terminals for its line and load standard terminals. As described by the National Electrical Code, a circuit breaker such as the HMDLB3800 is a device that should use non-automatic and automatic means to protect a system against overloads and short circuits without damaging itself. The HMDLB3800 has a non-replaceable trip unit. The circuit breaker has a molded case which is resistant to fungus and moisture and belongs to Series C of the circuit breakers manufactured by Eaton. For the connections, the circuit breaker allows feed-thru connections. The HMDLB3800 has a maximum continuous current rating of 800 Amps. Additionally, the Eaton HMDLB3800 has a maximum rated voltage of 600 Volts AC and has a high interrupt rating of 65 kiloamps interrupt capacity at 480 Volts AC, 100 kiloamps interrupt capacity at 240 Volts AC and 35 kiloamps interrupt capacity at 600 Volts AC. The HMDLB3800 has an M Frame size.

Having an M Frame size, the HMDLB3800 qualifies for reverse feed use (when factory assembled) and it bears the HACR rating. Additionally, circuit breakers with an M Frame size are available in their individual parts (frame, terminals, AND trip unit) allowing for user assembly. The HMDLB3800, as with other Eaton molded case circuit breakers, is CE marked. The Eaton HMDLB3800 complete molded case circuit breaker has 3 poles. When the HMDLB3800 is used to protect 250 Volts DC-powered systems, it has a minimum time constant of 3 milliseconds and 8 milliseconds at 10 kiloamps and 22 kiloamps, respectively. The HMDLB3800 measures 7.25 inches x 10.25 inches x 18.19 inches for the height, width, and depth, respectively. When the circuit breaker is to be installed in environments with a higher temperature (more than 40 degrees Celsius), or a different operating frequency, special calibrations can be requested when ordering the HMDLB3800.

Repair Services for HMDLB3800

Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your HMDLB3800. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Dimensions For HMDLB3800

Size
Input Type
Panel Cutout Height in mm
Panel Cutout Width in mm
Terminal Height in mm
Terminal Width in mm
Terminal Overall Depth in mm
Terminal Mounted Depth in mm

Dimensions For HMDLB3800

Resolutions For HMDLB3800

Technical Specifications
Part Number/Catalog No.HMDLB3800
Product TypeMolded Case Circuit Breaker
SeriesC
FrameF
Poles3
Amps800 Amps
Interrupting Capacity100 kAIC at 240 Volts AC
Unit Type310+
Dimensions (W x H x D)8.25 x 16 x 4.06 inches
Weight30 pounds
Part Number/Catalog No.HMDLB3800
Product TypeMolded Case Circuit Breaker
SeriesC
FrameF
Poles3
Amps800 Amps
Interrupting Capacity100 kAIC at 240 Volts AC
Unit Type310+
Dimensions (W x H x D)8.25 x 16 x 4.06 inches
Weight30 pounds
About

The Eaton Cutler-Hammer HMDLB3800 is a circuit breaker with a fixed thermal and a fixed magnetic trip unit. The circuit breaker uses the TA800MA2 terminals for its line and load standard terminals. As described by the National Electrical Code, a circuit breaker such as the HMDLB3800 is a device that should use non-automatic and automatic means to protect a system against overloads and short circuits without damaging itself. The HMDLB3800 has a non-replaceable trip unit. The circuit breaker has a molded case which is resistant to fungus and moisture and belongs to Series C of the circuit breakers manufactured by Eaton. For the connections, the circuit breaker allows feed-thru connections. The HMDLB3800 has a maximum continuous current rating of 800 Amps. Additionally, the Eaton HMDLB3800 has a maximum rated voltage of 600 Volts AC and has a high interrupt rating of 65 kiloamps interrupt capacity at 480 Volts AC, 100 kiloamps interrupt capacity at 240 Volts AC and 35 kiloamps interrupt capacity at 600 Volts AC. The HMDLB3800 has an M Frame size.

Having an M Frame size, the HMDLB3800 qualifies for reverse feed use (when factory assembled) and it bears the HACR rating. Additionally, circuit breakers with an M Frame size are available in their individual parts (frame, terminals, AND trip unit) allowing for user assembly. The HMDLB3800, as with other Eaton molded case circuit breakers, is CE marked. The Eaton HMDLB3800 complete molded case circuit breaker has 3 poles. When the HMDLB3800 is used to protect 250 Volts DC-powered systems, it has a minimum time constant of 3 milliseconds and 8 milliseconds at 10 kiloamps and 22 kiloamps, respectively. The HMDLB3800 measures 7.25 inches x 10.25 inches x 18.19 inches for the height, width, and depth, respectively. When the circuit breaker is to be installed in environments with a higher temperature (more than 40 degrees Celsius), or a different operating frequency, special calibrations can be requested when ordering the HMDLB3800.

Repairs
Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your HMDLB3800. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your HMDLB3800. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

PDF