MT3800T

MT3800T

Description: The Eaton MT3800T Trip Unit operates with 3 Poles and 800 Amps. It also has a F Frame and a Thermal Magnetic Unit Type.
Rated 4.6 with 8 reviews
top legal disclaimer
top legal disclaimer

credit cards accepted
better business bureau

Available Now

Submit RFQ for MT3800T

Add more parts to quote

Description: The Eaton MT3800T Trip Unit operates with 3 Poles and 800 Amps. It also has a F Frame and a Thermal Magnetic Unit Type.

Warranty: 1 year DO Supply Warranty Included
Shipping: Worldwide shipping via DHL, UPS, Fedex, and TNT
Repairs: We offer repair service for the MT3800T.
Exchange: Exchange credit for your defective unit available.

To speak to a sales representative for pricing & lead time:

phone

International
919-205-4392
phone

International
919-205-4392

Rated 4.6 with 8 reviews

    Technical Specifications for MT3800T

Part Number/Catalog No.MT3800T
Product TypeTrip Unit
SeriesC
FrameF
Poles3
Amps800
Interrupting CapacityStandard, High, or Ultra High
Unit TypeThermal Magnetic
Dimensions (W x H x D)8.25 x 16 x 4.06 in.
Weight4 lbs
Part Number/Catalog No.MT3800T
Product TypeTrip Unit
SeriesC
FrameF
Poles3
Amps800
Interrupting CapacityStandard, High, or Ultra High
Unit TypeThermal Magnetic
Dimensions (W x H x D)8.25 x 16 x 4.06 in.
Weight4 lbs

About MT3800T

The MT3800T is a circuit breaker and trip unit manufactured by Cutler-Hammer and it is from the Series C family of circuit breakers. It has an M frame type and it is a thermal magnetic trip unit. It has 3 poles and the MT3800T has a trip current rating of 800 Amps. The recommended ambient operating temperature of the device is 40 degrees Celsius and users can also order the device after it has been calibrated to be compatible with lower temperatures, for which special lubrication and mechanisms are used to make the device operate at temperatures as low as -40 degrees Celsius. It is a thermal magnetic unit which means that when the current that passes through the core increases, it energizes the core to create a magnetic field.

When the current goes beyond the current threshold, it causes enough of a magnetic field to pull the lever to cause the switch to trip. During short circuits where a high current passes through the MT3800, it helps in protecting the other connected devices from damage due to the short circuit. Before users turn on the power to the system after connecting the unit to other devices, they should make sure that they made the connections correctly and that the wires are secured in place. The contacts should not have any loose wires, in order to prevent any sparks and the risk of fire, and the switch should be in the off position. Follow the manufacturer’s instructions to ensure the safety of the equipment and safety for the people operating the device.

Repair Services for MT3800T

Type Lead Time Price Action
Repair Service 2-4 weeks $723.07cartAdd to Cart

Our highly skilled technicians can repair your MT3800T. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Dimensions For MT3800T

Size
Input Type
Panel Cutout Height in mm
Panel Cutout Width in mm
Terminal Height in mm
Terminal Width in mm
Terminal Overall Depth in mm
Terminal Mounted Depth in mm

Dimensions For MT3800T

Resolutions For MT3800T

Technical Specifications
Part Number/Catalog No.MT3800T
Product TypeTrip Unit
SeriesC
FrameF
Poles3
Amps800
Interrupting CapacityStandard, High, or Ultra High
Unit TypeThermal Magnetic
Dimensions (W x H x D)8.25 x 16 x 4.06 in.
Weight4 lbs
Part Number/Catalog No.MT3800T
Product TypeTrip Unit
SeriesC
FrameF
Poles3
Amps800
Interrupting CapacityStandard, High, or Ultra High
Unit TypeThermal Magnetic
Dimensions (W x H x D)8.25 x 16 x 4.06 in.
Weight4 lbs
About

The MT3800T is a circuit breaker and trip unit manufactured by Cutler-Hammer and it is from the Series C family of circuit breakers. It has an M frame type and it is a thermal magnetic trip unit. It has 3 poles and the MT3800T has a trip current rating of 800 Amps. The recommended ambient operating temperature of the device is 40 degrees Celsius and users can also order the device after it has been calibrated to be compatible with lower temperatures, for which special lubrication and mechanisms are used to make the device operate at temperatures as low as -40 degrees Celsius. It is a thermal magnetic unit which means that when the current that passes through the core increases, it energizes the core to create a magnetic field.

When the current goes beyond the current threshold, it causes enough of a magnetic field to pull the lever to cause the switch to trip. During short circuits where a high current passes through the MT3800, it helps in protecting the other connected devices from damage due to the short circuit. Before users turn on the power to the system after connecting the unit to other devices, they should make sure that they made the connections correctly and that the wires are secured in place. The contacts should not have any loose wires, in order to prevent any sparks and the risk of fire, and the switch should be in the off position. Follow the manufacturer’s instructions to ensure the safety of the equipment and safety for the people operating the device.

Repairs
Type Lead Time Price Action
Repair Service 2-4 weeks $723.07cartAdd to Cart

Our highly skilled technicians can repair your MT3800T. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Type Lead Time Price Action
Repair Service 2-4 weeks $723.07cartAdd to Cart

Our highly skilled technicians can repair your MT3800T. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

PDF