CHND3800T56W
Warranty: | 1 year DO Supply Warranty Included |
Shipping: | Worldwide shipping via DHL, UPS, Fedex, and TNT |
Repairs: | We offer repair service for the CHND3800T56W. |
Exchange: | Exchange credit for your defective unit available. |
Part Number/Catalog No. | CHND3800T56W |
Product Type | Molded Case Circuit Breaker |
Series | C |
Frame | N |
Poles | 3 |
Amps | 800 Amps |
Trip Model | Model 550 |
Trip Type | LSIG |
Interrupting Capacity | 100 kAIC at 240 Volts AC |
Dimensions (W x H x D) | 8.25 x 16 x 5.5 inches |
Weight | 45 pounds |
Part Number/Catalog No. | CHND3800T56W |
Product Type | Molded Case Circuit Breaker |
Series | C |
Frame | N |
Poles | 3 |
Amps | 800 Amps |
Trip Model | Model 550 |
Trip Type | LSIG |
Interrupting Capacity | 100 kAIC at 240 Volts AC |
Dimensions (W x H x D) | 8.25 x 16 x 5.5 inches |
Weight | 45 pounds |
The 3-pole Eaton CHND3800T56W is an 800 Amps, 600 Volts AC rated CHND type of circuit breaker. It is a complete breaker with an electronic trip unit. The interrupting capacity ratings for the breaker are 65 kAIC at 480 Volts AC and 100 kAIC at 240 Volts AC. The weight of the CHND3800T56W is 19.9 kilograms and the dimensions of the breaker enclosure are 215.9 x 215.9 x 139.7 millimeters. The OPTIM 550 LSIG trip is part of the CHND3800T56W. The OPTIM 550 is programmable and it supports RMS sensing. The current range that is supported runs from 70 to 1200 Amps and the interrupting range is 30 to 100 kA. The rating plug is interchangeable and the module supports an over-temperature trip. The device features include a digital display, trip information, LEDs that indicate the cause of trips, and monitoring for the current. The IMPACC field communications features are field upgradable. The testing methods available are the OTP, BIM, and IMPACC.
The 100% rated, NG frame CHND3800T56W does not have terminals. Terminals can be purchased from the manufacturer. The internal accessories that are available include the shunt trip, alarm switch, and under-voltage release mechanism. The CHND3800T56W does not need ventilation. It can be operated at 100% of the frame rating in an enclosure with the following dimensions: 42 inches in height, 22.75 inches in width, and 11.5 inches in depth. The high voltage in energized equipment can cause damage, injury, and death. Therefore, prior to mounting the breaker in a system, ensure that the working area is clear of voltages and that all the electrical equipment nearby is powered off. Special care is required for reverse feed applications.
Type | Lead Time | Price | Action |
---|---|---|---|
Repair Service | 2-4 weeks | Ask | ![]() |
Our highly skilled technicians can repair your CHND3800T56W. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.
Size | |
Input Type | |
Panel Cutout Height | in mm |
Panel Cutout Width | in mm |
Terminal Height | in mm |
Terminal Width | in mm |
Terminal Overall Depth | in mm |
Terminal Mounted Depth | in mm |
Part Number/Catalog No. | CHND3800T56W |
Product Type | Molded Case Circuit Breaker |
Series | C |
Frame | N |
Poles | 3 |
Amps | 800 Amps |
Trip Model | Model 550 |
Trip Type | LSIG |
Interrupting Capacity | 100 kAIC at 240 Volts AC |
Dimensions (W x H x D) | 8.25 x 16 x 5.5 inches |
Weight | 45 pounds |
Part Number/Catalog No. | CHND3800T56W |
Product Type | Molded Case Circuit Breaker |
Series | C |
Frame | N |
Poles | 3 |
Amps | 800 Amps |
Trip Model | Model 550 |
Trip Type | LSIG |
Interrupting Capacity | 100 kAIC at 240 Volts AC |
Dimensions (W x H x D) | 8.25 x 16 x 5.5 inches |
Weight | 45 pounds |
The 3-pole Eaton CHND3800T56W is an 800 Amps, 600 Volts AC rated CHND type of circuit breaker. It is a complete breaker with an electronic trip unit. The interrupting capacity ratings for the breaker are 65 kAIC at 480 Volts AC and 100 kAIC at 240 Volts AC. The weight of the CHND3800T56W is 19.9 kilograms and the dimensions of the breaker enclosure are 215.9 x 215.9 x 139.7 millimeters. The OPTIM 550 LSIG trip is part of the CHND3800T56W. The OPTIM 550 is programmable and it supports RMS sensing. The current range that is supported runs from 70 to 1200 Amps and the interrupting range is 30 to 100 kA. The rating plug is interchangeable and the module supports an over-temperature trip. The device features include a digital display, trip information, LEDs that indicate the cause of trips, and monitoring for the current. The IMPACC field communications features are field upgradable. The testing methods available are the OTP, BIM, and IMPACC.
The 100% rated, NG frame CHND3800T56W does not have terminals. Terminals can be purchased from the manufacturer. The internal accessories that are available include the shunt trip, alarm switch, and under-voltage release mechanism. The CHND3800T56W does not need ventilation. It can be operated at 100% of the frame rating in an enclosure with the following dimensions: 42 inches in height, 22.75 inches in width, and 11.5 inches in depth. The high voltage in energized equipment can cause damage, injury, and death. Therefore, prior to mounting the breaker in a system, ensure that the working area is clear of voltages and that all the electrical equipment nearby is powered off. Special care is required for reverse feed applications.
Type | Lead Time | Price | Action |
---|---|---|---|
Repair Service | 2-4 weeks | Ask | ![]() |
Our highly skilled technicians can repair your CHND3800T56W. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.
Type | Lead Time | Price | Action |
---|---|---|---|
Repair Service | 2-4 weeks | Ask | ![]() |
Our highly skilled technicians can repair your CHND3800T56W. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.