CND312T107W

CND312T107W

Description: The CND312T107W Molded Case Circuit Breaker operates with 3 Poles and 1200 Amps. The module also has a N Frame and a Model 1050 Trip Model.
Rated 4.5 with 7 reviews
top legal disclaimer
top legal disclaimer

credit cards accepted
better business bureau

Available Now

Submit RFQ for CND312T107W

Add more parts to quote

Description: The CND312T107W Molded Case Circuit Breaker operates with 3 Poles and 1200 Amps. The module also has a N Frame and a Model 1050 Trip Model.

Warranty: 1 year DO Supply Warranty Included
Shipping: Worldwide shipping via DHL, UPS, Fedex, and TNT
Repairs: We offer repair service for the CND312T107W.
Exchange: Exchange credit for your defective unit available.

To Speak to a sales representative for pricing & lead time:

phone

International
919-205-4392

Rated 4.5 with 7 reviews

    Technical Specifications for CND312T107W

Part Number/Catalog No.CND312T107W
Product TypeMolded Case Circuit Breaker
SeriesC
FrameN
Poles3
Amps1200 Amps
Trip ModelModel 1050
Trip TypeLSIA
Interrupting Capacity65 kAIC at 240 Volts AC
Dimensions (W x H x D)8.25 x 16 x 5.5 inches
Weight45 pounds
Part Number/Catalog No.CND312T107W
Product TypeMolded Case Circuit Breaker
SeriesC
FrameN
Poles3
Amps1200 Amps
Trip ModelModel 1050
Trip TypeLSIA
Interrupting Capacity65 kAIC at 240 Volts AC
Dimensions (W x H x D)8.25 x 16 x 5.5 inches
Weight45 pounds
s

About CND312T107W

The Eaton CND312T107W is a CND type 1200 Amps/600 Volts AC rated electronic circuit breaker. The CND312T107W supports operation at a 100% rating in an enclosure measuring at least 42 x 22.75 x 11.5 inches in dimensions. The CND312T107W has a weight of 45 pounds and its dimensions are the following: 8.25 inches in width, 8.25 inches in height, and 5.5 inches length. The CND312T107W requires a ventilation space of 0.0258 square meters to the left, 0.0258 square meters to the right, 0.0465 square meters to the top, and 0.0465 square meters to the bottom of the device. The CND312T107W is a 3-pole NG-frame device which does not include terminals. It must be used with supplied conductor extensions and terminal barriers. Only AL9CU or copper terminals and 194 degrees Fahrenheit rated wire are recommended for use with this device. It supports 50 to 60 Hertz of frequency. The following are the interrupt capacity ratings for the CND312T107W: 50 kAIC at 480 Volts AC and 85 kAIC at 240 Volts AC.

The CND312T107W must be installed only after its specifications comply with all the system requirements. Precautions to be following during installation include switching off the breaker and other electrical equipment and clearing the working area of all voltage. The breaker cover constrains the moving breaker parts and it should always be in place during operation. The CND312T107W is provided with an OPTIM 1050 trip unit (LSIA option) which supports advanced features including diagnostics, true RMS sensing, and the monitoring of various breaker parameters, including current and energy.  An overload trip is initiated within 2 hours when a 135% overload occurs, and it is initiated in less time for overloads higher than 135%.

Repair Services for CND312T107W

Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your CND312T107W. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Dimensions For CND312T107W

Size
Input Type
Panel Cutout Height in mm
Panel Cutout Width in mm
Terminal Height in mm
Terminal Width in mm
Terminal Overall Depth in mm
Terminal Mounted Depth in mm

Dimensions For CND312T107W

Resolutions For CND312T107W

Technical Specifications
Part Number/Catalog No.CND312T107W
Product TypeMolded Case Circuit Breaker
SeriesC
FrameN
Poles3
Amps1200 Amps
Trip ModelModel 1050
Trip TypeLSIA
Interrupting Capacity65 kAIC at 240 Volts AC
Dimensions (W x H x D)8.25 x 16 x 5.5 inches
Weight45 pounds
Part Number/Catalog No.CND312T107W
Product TypeMolded Case Circuit Breaker
SeriesC
FrameN
Poles3
Amps1200 Amps
Trip ModelModel 1050
Trip TypeLSIA
Interrupting Capacity65 kAIC at 240 Volts AC
Dimensions (W x H x D)8.25 x 16 x 5.5 inches
Weight45 pounds
About

The Eaton CND312T107W is a CND type 1200 Amps/600 Volts AC rated electronic circuit breaker. The CND312T107W supports operation at a 100% rating in an enclosure measuring at least 42 x 22.75 x 11.5 inches in dimensions. The CND312T107W has a weight of 45 pounds and its dimensions are the following: 8.25 inches in width, 8.25 inches in height, and 5.5 inches length. The CND312T107W requires a ventilation space of 0.0258 square meters to the left, 0.0258 square meters to the right, 0.0465 square meters to the top, and 0.0465 square meters to the bottom of the device. The CND312T107W is a 3-pole NG-frame device which does not include terminals. It must be used with supplied conductor extensions and terminal barriers. Only AL9CU or copper terminals and 194 degrees Fahrenheit rated wire are recommended for use with this device. It supports 50 to 60 Hertz of frequency. The following are the interrupt capacity ratings for the CND312T107W: 50 kAIC at 480 Volts AC and 85 kAIC at 240 Volts AC.

The CND312T107W must be installed only after its specifications comply with all the system requirements. Precautions to be following during installation include switching off the breaker and other electrical equipment and clearing the working area of all voltage. The breaker cover constrains the moving breaker parts and it should always be in place during operation. The CND312T107W is provided with an OPTIM 1050 trip unit (LSIA option) which supports advanced features including diagnostics, true RMS sensing, and the monitoring of various breaker parameters, including current and energy.  An overload trip is initiated within 2 hours when a 135% overload occurs, and it is initiated in less time for overloads higher than 135%.

Repairs
Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your CND312T107W. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your CND312T107W. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

PDF