Description: The Eaton LGE3500FAG Molded Case Circuit Breaker operates with 3 Poles and 500 Amps. The module has a LG Frame and a 630 A Max. Rated Current.
Rated 5 with 8 reviews
top legal disclaimer
top legal disclaimer

credit cards accepted
better business bureau

Available Now

Submit RFQ for LGE3500FAG

Add more parts to quote

Description: The Eaton LGE3500FAG Molded Case Circuit Breaker operates with 3 Poles and 500 Amps. The module has a LG Frame and a 630 A Max. Rated Current.

Warranty: 1 year DO Supply Warranty Included
Shipping: Worldwide shipping via DHL, UPS, Fedex, and TNT
Repairs: We offer repair service for the LGE3500FAG.
Exchange: Exchange credit for your defective unit available.

To speak to a sales representative for pricing & lead time:


Rated 5 with 8 reviews

    Technical Specifications for LGE3500FAG

Part Number/Catalog No.LGE3500FAG
Product TypeMolded Case Circuit Breaker
FrameLG
Interrupting Capacity35 kAIC at 480 Volts AC
Poles3
Amps500 Amps
Trip UnitFixed Adjustment
TerminationsLine/Load Standard
Maximum Rated Current630 Amps
Main Conducting Paths750 Volts AC
Endurance8,000 Operating Cycles
Maximum Switching Frequency240 1/h
Rated Making Capacity20 Amps
Rated Operational Voltage125 to 250 Volts
Part Number/Catalog No.LGE3500FAG
Product TypeMolded Case Circuit Breaker
FrameLG
Interrupting Capacity35 kAIC at 480 Volts AC
Poles3
Amps500 Amps
Trip UnitFixed Adjustment
TerminationsLine/Load Standard
Maximum Rated Current630 Amps
Main Conducting Paths750 Volts AC
Endurance8,000 Operating Cycles
Maximum Switching Frequency240 1/h
Rated Making Capacity20 Amps
Rated Operational Voltage125 to 250 Volts
s

About LGE3500FAG

The LGE3500FAG is a Series G circuit breaker from Eaton. The circuit breaker is an L Frame breaker and it has to be used in accordance with the IEC, CSA, CE, and the UL regulations. The circuit breaker has a maximum current rating of 500 Amps and it has 3 poles. The trip unit inside the breaker is a fixed adjustable trip unit and it is shipped with the standard line and load terminals. While installing the LGE3500FAG, make sure the power to the system is turned off and that there is no voltage present. There may be the danger of electric shock. The users must follow the installation instructions provided by the manufacturer to ensure the correct installation procedure.



The installation must be performed by technicians who are familiar with installing electrical devices for high voltage applications. The load and the line terminals must be installed and secured in place so that they do not come out and so they are held securely. The users can contact the supplier for any assistance regarding the part number or any of the installation instructions. The LGE3500FAG circuit breaker must be inspected from time to time to verify the correct operation of the device. Any dust must be cleaned off and moisture should be wiped off with a lint-free cloth. The circuit breaker measures 5.48 inches in width, 10.13 inches in height, and 4.09 inches in depth. Before the LGE3500FAG is given to the users, technicians should perform all the necessary functional tests and inspections to ensure the safety of the users.



Repair Services for LGE3500FAG

Type Lead Time Price Action
Repair Service 2-4 weeks $3088.9cartAdd to Cart

Our highly skilled technicians can repair your LGE3500FAG. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Dimensions For LGE3500FAG

Size
Input Type
Panel Cutout Height in mm
Panel Cutout Width in mm
Terminal Height in mm
Terminal Width in mm
Terminal Overall Depth in mm
Terminal Mounted Depth in mm

Dimensions For LGE3500FAG

Resolutions For LGE3500FAG

About

Technical Specifications for LGE3500FAG

Part Number/Catalog No.LGE3500FAG
Product TypeMolded Case Circuit Breaker
FrameLG
Interrupting Capacity35 kAIC at 480 Volts AC
Poles3
Amps500 Amps
Trip UnitFixed Adjustment
TerminationsLine/Load Standard
Maximum Rated Current630 Amps
Main Conducting Paths750 Volts AC
Endurance8,000 Operating Cycles
Maximum Switching Frequency240 1/h
Rated Making Capacity20 Amps
Rated Operational Voltage125 to 250 Volts
Part Number/Catalog No.LGE3500FAG
Product TypeMolded Case Circuit Breaker
FrameLG
Interrupting Capacity35 kAIC at 480 Volts AC
Poles3
Amps500 Amps
Trip UnitFixed Adjustment
TerminationsLine/Load Standard
Maximum Rated Current630 Amps
Main Conducting Paths750 Volts AC
Endurance8,000 Operating Cycles
Maximum Switching Frequency240 1/h
Rated Making Capacity20 Amps
Rated Operational Voltage125 to 250 Volts

About LGE3500FAG

The LGE3500FAG is a Series G circuit breaker from Eaton. The circuit breaker is an L Frame breaker and it has to be used in accordance with the IEC, CSA, CE, and the UL regulations. The circuit breaker has a maximum current rating of 500 Amps and it has 3 poles. The trip unit inside the breaker is a fixed adjustable trip unit and it is shipped with the standard line and load terminals. While installing the LGE3500FAG, make sure the power to the system is turned off and that there is no voltage present. There may be the danger of electric shock. The users must follow the installation instructions provided by the manufacturer to ensure the correct installation procedure.



The installation must be performed by technicians who are familiar with installing electrical devices for high voltage applications. The load and the line terminals must be installed and secured in place so that they do not come out and so they are held securely. The users can contact the supplier for any assistance regarding the part number or any of the installation instructions. The LGE3500FAG circuit breaker must be inspected from time to time to verify the correct operation of the device. Any dust must be cleaned off and moisture should be wiped off with a lint-free cloth. The circuit breaker measures 5.48 inches in width, 10.13 inches in height, and 4.09 inches in depth. Before the LGE3500FAG is given to the users, technicians should perform all the necessary functional tests and inspections to ensure the safety of the users.



Repairs
Type Lead Time Price Action
Repair Service 2-4 weeks $3088.9cartAdd to Cart

Our highly skilled technicians can repair your LGE3500FAG. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Type Lead Time Price Action
Repair Service 2-4 weeks $3088.9cartAdd to Cart

Our highly skilled technicians can repair your LGE3500FAG. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

PDF