JGH325032G

JGH325032G

Description: The Eaton JGH325032G Molded Case Circuit Breaker has a JG Frame and 65 kA @ 480V. The module operates with 3 Pole(s) and 250 Amps.
Rated 4.8 with 17 reviews
top legal disclaimer
top legal disclaimer

credit cards accepted
better business bureau

Available Now

Submit RFQ for JGH325032G

Add more parts to quote

Description:

The Eaton JGH325032G Molded Case Circuit Breaker has a JG Frame and 65 kA @ 480V. The module operates with 3 Pole(s) and 250 Amps.



Warranty: 1 year DO Supply Warranty Included
Shipping: Worldwide shipping via DHL, UPS, Fedex, and TNT
Repairs: We offer repair service for the JGH325032G.
Exchange: Exchange credit for your defective unit available.

To Speak to a sales representative for pricing & lead time:

phone

International
919-205-4392

Rated 4.8 with 17 reviews

    Technical Specifications for JGH325032G

Part Number/Catalog No.JGH325032G
Product TypeMolded Case Circuit Breaker
FrameJG
kA @ 480V65
Pole(s)3
Amps250
Trip Unit310+ electronic LSI
TerminationsLine/Load Standard
Rating80%
Max. Rated Current250 A
Auxiliary Circuits690V AC
Main Conducting Paths8 kV
Max. Switching Frequency240 1/h
Weight6 lbs
Dimensions (W x H x D)4.3 x 7 x 3.57 in.
Part Number/Catalog No.JGH325032G
Product TypeMolded Case Circuit Breaker
FrameJG
kA @ 480V65
Pole(s)3
Amps250
Trip Unit310+ electronic LSI
TerminationsLine/Load Standard
Rating80%
Max. Rated Current250 A
Auxiliary Circuits690V AC
Main Conducting Paths8 kV
Max. Switching Frequency240 1/h
Weight6 lbs
Dimensions (W x H x D)4.3 x 7 x 3.57 in.
s

About JGH325032G

The Eaton Cutler-Hammer JGH325032G circuit breaker is a circuit breaker with the standard line and load terminals and a current rating of 250 Amps. The circuit breaker uses a Digitrip 310+ trip mechanism. The mechanism has RMS (root-mean-square) current sensing. This current sensing method establishes the current of non-sinusoidal and sinusoidal waveforms by repeatedly sampling the current waveform and then calculating the true RMS value. Additionally, the trip mechanism features LSI trip functions. These functions include long-time delay, long-time ampere rating, defeatable instantaneous pickup, short-time delay, and short-time pickup functions.

The JGH325032G circuit breaker’s Digitrip 310+ trip mechanism does not support Arcflash Reduction Maintenance System (ARMS) or a fixed rated plug. However, the breaker has over-temperature trip protection. The circuit breaker has a long delay time ranging from a minimum of 2 seconds to a maximum of 24 seconds, a long delay pickup of between 40 to 100% of the frame size, a thermal memory, and a high load alarm. For instantaneous protection, the JGH325032G circuit breaker does not feature an instantaneous pickup but it does feature an instantaneous override. The circuit breaker is 80% rated. The JGH325032G circuit breaker, like other Eaton circuit breakers, can be used in individual enclosures and in distribution systems to provide main and branch circuit protection. It can also be used in busbar trunking tap-offs to provide circuit protection. The Eaton JGH325032G circuit breaker, like other Eaton  Cutler-Hammer circuit breakers in the Series G family and with J frames, has a NEMA rated operating voltage of 600 Volts AC and an IEC rated operating voltage of 690 Volts AC.

Repair Services for JGH325032G

Type Lead Time Price Action
Repair Service 2-4 weeks $1772.29cartAdd to Cart

Our highly skilled technicians can repair your JGH325032G. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Dimensions For JGH325032G

Size
Input Type
Panel Cutout Height in mm
Panel Cutout Width in mm
Terminal Height in mm
Terminal Width in mm
Terminal Overall Depth in mm
Terminal Mounted Depth in mm

Dimensions For JGH325032G

Resolutions For JGH325032G

Technical Specifications
Part Number/Catalog No.JGH325032G
Product TypeMolded Case Circuit Breaker
FrameJG
kA @ 480V65
Pole(s)3
Amps250
Trip Unit310+ electronic LSI
TerminationsLine/Load Standard
Rating80%
Max. Rated Current250 A
Auxiliary Circuits690V AC
Main Conducting Paths8 kV
Max. Switching Frequency240 1/h
Weight6 lbs
Dimensions (W x H x D)4.3 x 7 x 3.57 in.
Part Number/Catalog No.JGH325032G
Product TypeMolded Case Circuit Breaker
FrameJG
kA @ 480V65
Pole(s)3
Amps250
Trip Unit310+ electronic LSI
TerminationsLine/Load Standard
Rating80%
Max. Rated Current250 A
Auxiliary Circuits690V AC
Main Conducting Paths8 kV
Max. Switching Frequency240 1/h
Weight6 lbs
Dimensions (W x H x D)4.3 x 7 x 3.57 in.
About

The Eaton Cutler-Hammer JGH325032G circuit breaker is a circuit breaker with the standard line and load terminals and a current rating of 250 Amps. The circuit breaker uses a Digitrip 310+ trip mechanism. The mechanism has RMS (root-mean-square) current sensing. This current sensing method establishes the current of non-sinusoidal and sinusoidal waveforms by repeatedly sampling the current waveform and then calculating the true RMS value. Additionally, the trip mechanism features LSI trip functions. These functions include long-time delay, long-time ampere rating, defeatable instantaneous pickup, short-time delay, and short-time pickup functions.

The JGH325032G circuit breaker’s Digitrip 310+ trip mechanism does not support Arcflash Reduction Maintenance System (ARMS) or a fixed rated plug. However, the breaker has over-temperature trip protection. The circuit breaker has a long delay time ranging from a minimum of 2 seconds to a maximum of 24 seconds, a long delay pickup of between 40 to 100% of the frame size, a thermal memory, and a high load alarm. For instantaneous protection, the JGH325032G circuit breaker does not feature an instantaneous pickup but it does feature an instantaneous override. The circuit breaker is 80% rated. The JGH325032G circuit breaker, like other Eaton circuit breakers, can be used in individual enclosures and in distribution systems to provide main and branch circuit protection. It can also be used in busbar trunking tap-offs to provide circuit protection. The Eaton JGH325032G circuit breaker, like other Eaton  Cutler-Hammer circuit breakers in the Series G family and with J frames, has a NEMA rated operating voltage of 600 Volts AC and an IEC rated operating voltage of 690 Volts AC.

Repairs
Type Lead Time Price Action
Repair Service 2-4 weeks $1772.29cartAdd to Cart

Our highly skilled technicians can repair your JGH325032G. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Type Lead Time Price Action
Repair Service 2-4 weeks $1772.29cartAdd to Cart

Our highly skilled technicians can repair your JGH325032G. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

PDF