NGH308033E

NGH308033E

Description: The Eaton NGH308033E Molded Case Circuit Breaker operates with 3 Poles and 80 Amps. It also has Imperial tapped line/load conductor Terminations and a 600 V Rated Operational Voltage.
Rated 4.6 with 18 reviews
top legal disclaimer
top legal disclaimer

credit cards accepted
better business bureau

Available Now

Submit RFQ for NGH308033E

Add more parts to quote

Description: The Eaton NGH308033E Molded Case Circuit Breaker operates with 3 Poles and 80 Amps. It also has Imperial tapped line/load conductor Terminations and a 600 V Rated Operational Voltage.

Warranty: 1 year DO Supply Warranty Included
Shipping: Worldwide shipping via DHL, UPS, Fedex, and TNT
Repairs: We offer repair service for the NGH308033E.
Exchange: Exchange credit for your defective unit available.

To Speak to a sales representative for pricing & lead time:

phone

International
919-205-4392

Rated 4.6 with 18 reviews

    Technical Specifications for NGH308033E

Part Number/Catalog No.NGH308033E
Product TypeMolded Case Circuit Breaker
FrameNG
kAIC @ 480 VAC65
Poles3
Amps80
Trip Unit310+ Electronic LS
TerminationsImperial tapped line/load conductor
Max. Rated Current1200 A
Main Conducting Paths750 VAC
Max. Switching Frequency60 1/h
Rated Making Capacity20 A
Max. Opening Time62 ms
Rated Operational Voltage600 V
Part Number/Catalog No.NGH308033E
Product TypeMolded Case Circuit Breaker
FrameNG
kAIC @ 480 VAC65
Poles3
Amps80
Trip Unit310+ Electronic LS
TerminationsImperial tapped line/load conductor
Max. Rated Current1200 A
Main Conducting Paths750 VAC
Max. Switching Frequency60 1/h
Rated Making Capacity20 A
Max. Opening Time62 ms
Rated Operational Voltage600 V
s

About NGH308033E

The NGH308033E is a 3-Pole Series-G Cutler-Hammer High Interrupting Capacity Circuit Breaker with a Digitrip RMS 310+ Electronic Trip Unit manufactured by the Eaton Corporation. It is rated at 800 Amps continuous current, 480 Volts AC maximum operating voltage, 65 kA at 480 Volts AC and 100 kA at 240 Volts AC interrupting capacity, NG-Frame. Like all NG-Frame circuit breakers manufactured by Eaton, the NGH308033E molded case circuit breaker is suitable for reverse feed use and it can be used to provide high-performance equipment control as well as overload, short circuit, fault currents, and overheat protection for a wide array of equipment and conductor within its rating in different industries.

Imperial end tapped terminals are available on the line and load terminals of the NGH308033E circuit breaker and it incorporates the best arc extinguishing technologies. Its fully adjustable Digitrip RMS 310+ Electronic Trip Unit provides microprocessor-based true RMS sensing to improve its protective systems and to prevent nuisance trips better. It also features a test jack and push-to-trip button for the trip unit. Its rugged glass-polyester casing protects all its components from moisture, dust, and fungus in different environments. The NGH308033E circuit breaker features a toggle type switch operating mechanism which also indicates its on, off, or tripped status and it supports the use of many accessories such as alarm switches, auxiliary switches, shunt trips, under-voltage release mechanisms, meters, and the cause of trip displays. Failure to match the NGH308033E circuit breaker with equipment in within its rating can result in limited performance, damage, or injury to personnel.

Repair Services for NGH308033E

Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your NGH308033E. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Dimensions For NGH308033E

Size
Input Type
Panel Cutout Height in mm
Panel Cutout Width in mm
Terminal Height in mm
Terminal Width in mm
Terminal Overall Depth in mm
Terminal Mounted Depth in mm

Dimensions For NGH308033E

Resolutions For NGH308033E

Technical Specifications
Part Number/Catalog No.NGH308033E
Product TypeMolded Case Circuit Breaker
FrameNG
kAIC @ 480 VAC65
Poles3
Amps80
Trip Unit310+ Electronic LS
TerminationsImperial tapped line/load conductor
Max. Rated Current1200 A
Main Conducting Paths750 VAC
Max. Switching Frequency60 1/h
Rated Making Capacity20 A
Max. Opening Time62 ms
Rated Operational Voltage600 V
Part Number/Catalog No.NGH308033E
Product TypeMolded Case Circuit Breaker
FrameNG
kAIC @ 480 VAC65
Poles3
Amps80
Trip Unit310+ Electronic LS
TerminationsImperial tapped line/load conductor
Max. Rated Current1200 A
Main Conducting Paths750 VAC
Max. Switching Frequency60 1/h
Rated Making Capacity20 A
Max. Opening Time62 ms
Rated Operational Voltage600 V
About

The NGH308033E is a 3-Pole Series-G Cutler-Hammer High Interrupting Capacity Circuit Breaker with a Digitrip RMS 310+ Electronic Trip Unit manufactured by the Eaton Corporation. It is rated at 800 Amps continuous current, 480 Volts AC maximum operating voltage, 65 kA at 480 Volts AC and 100 kA at 240 Volts AC interrupting capacity, NG-Frame. Like all NG-Frame circuit breakers manufactured by Eaton, the NGH308033E molded case circuit breaker is suitable for reverse feed use and it can be used to provide high-performance equipment control as well as overload, short circuit, fault currents, and overheat protection for a wide array of equipment and conductor within its rating in different industries.

Imperial end tapped terminals are available on the line and load terminals of the NGH308033E circuit breaker and it incorporates the best arc extinguishing technologies. Its fully adjustable Digitrip RMS 310+ Electronic Trip Unit provides microprocessor-based true RMS sensing to improve its protective systems and to prevent nuisance trips better. It also features a test jack and push-to-trip button for the trip unit. Its rugged glass-polyester casing protects all its components from moisture, dust, and fungus in different environments. The NGH308033E circuit breaker features a toggle type switch operating mechanism which also indicates its on, off, or tripped status and it supports the use of many accessories such as alarm switches, auxiliary switches, shunt trips, under-voltage release mechanisms, meters, and the cause of trip displays. Failure to match the NGH308033E circuit breaker with equipment in within its rating can result in limited performance, damage, or injury to personnel.

Repairs
Type Lead Time Price Action