NGH312036E

NGH312036E

Description: The Eaton NGH312036E Molded Case Circuit Breaker operates with 3 Poles and 120 Amps. It also has Imperial tapped line/load conductor Terminations and a 600 V Rated Operational Voltage.
Rated 4.5 with 20 reviews
top legal disclaimer
top legal disclaimer

credit cards accepted
better business bureau

Available Now

Submit RFQ for NGH312036E

Add more parts to quote

Description: The Eaton NGH312036E Molded Case Circuit Breaker operates with 3 Poles and 120 Amps. It also has Imperial tapped line/load conductor Terminations and a 600 V Rated Operational Voltage.

Warranty: 1 year DO Supply Warranty Included
Shipping: Worldwide shipping via DHL, UPS, Fedex, and TNT
Repairs: We offer repair service for the NGH312036E.
Exchange: Exchange credit for your defective unit available.

To Speak to a sales representative for pricing & lead time:

phone

International
919-205-4392

Rated 4.5 with 20 reviews

    Technical Specifications for NGH312036E

Part Number/Catalog No.NGH312036E
Product TypeMolded Case Circuit Breaker
FrameNG
kAIC @ 480 VAC65
Poles3
Amps120
Trip Unit310+ Electronic LSIG
TerminationsImperial tapped line/load conductor
Max. Rated Current1200 A
Main Conducting Paths750 VAC
Max. Switching Frequency60 1/h
Rated Making Capacity20 A
Max. Opening Time62 ms
Rated Operational Voltage600 V
Part Number/Catalog No.NGH312036E
Product TypeMolded Case Circuit Breaker
FrameNG
kAIC @ 480 VAC65
Poles3
Amps120
Trip Unit310+ Electronic LSIG
TerminationsImperial tapped line/load conductor
Max. Rated Current1200 A
Main Conducting Paths750 VAC
Max. Switching Frequency60 1/h
Rated Making Capacity20 A
Max. Opening Time62 ms
Rated Operational Voltage600 V
s

About NGH312036E

The NGH312036E is a 3-pole Series G Eaton Cutler-Hammer molded case circuit breaker. The NGH312036E has a size NG frame, a maximum operating current of 1200 Amps (maximum) and 800 Amps (minimum), and an electronic LSIG trip unit. At a frequency range of 50 to 60 Hertz, the circuit breaker has a capacity of 100 kAIC at 240 Volts AC, 65 kAIC at 480 Volts AC, and 35 kAIC at 600 Volts AC. The NGH312036E can accommodate a maximum voltage of 690 Volts AC (IEC) and 600 Volts AC (NEMA). Eaton molded-case circuit breakers with an NG frame size have 750 Volts AC insulation voltage for the main conducting paths, 690 Volts AC insulation voltage for the main auxiliary circuits, and 8 kilovolts rated inputs withstand voltage for the main conducting paths.

Additionally, the NGH312036E Eaton Cutler-Hammer circuit breaker has a 4 kilovolts rated impulse for the auxiliary circuits. Having an NG frame, the NGH312036E has flat bar terminals which accommodate a torque of 50 N-m. When circuit breakers with the NG frame size like the NGH312036E are used for plant protection or as isolating circuit breakers, they have a power loss of between 87 and 210 Watts. The trip unit for the NGH312036E Eaton circuit breaker is factory installed. The circuit breaker can be installed in individual enclosures, switchgear, feeder pillars, panelboards, and bus bar trunking tap-offs. The rated operating temperature for the NGH312036E is a maximum of 70 degrees Celsius and a minimum of -20 degrees Celsius.

Repair Services for NGH312036E

Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your NGH312036E. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Dimensions For NGH312036E

Size
Input Type
Panel Cutout Height in mm
Panel Cutout Width in mm
Terminal Height in mm
Terminal Width in mm
Terminal Overall Depth in mm
Terminal Mounted Depth in mm

Dimensions For NGH312036E

Resolutions For NGH312036E

Technical Specifications
Part Number/Catalog No.NGH312036E
Product TypeMolded Case Circuit Breaker
FrameNG
kAIC @ 480 VAC65
Poles3
Amps120
Trip Unit310+ Electronic LSIG
TerminationsImperial tapped line/load conductor
Max. Rated Current1200 A
Main Conducting Paths750 VAC
Max. Switching Frequency60 1/h
Rated Making Capacity20 A
Max. Opening Time62 ms
Rated Operational Voltage600 V
Part Number/Catalog No.NGH312036E
Product TypeMolded Case Circuit Breaker
FrameNG
kAIC @ 480 VAC65
Poles3
Amps120
Trip Unit310+ Electronic LSIG
TerminationsImperial tapped line/load conductor
Max. Rated Current1200 A
Main Conducting Paths750 VAC
Max. Switching Frequency60 1/h
Rated Making Capacity20 A
Max. Opening Time62 ms
Rated Operational Voltage600 V
About

The NGH312036E is a 3-pole Series G Eaton Cutler-Hammer molded case circuit breaker. The NGH312036E has a size NG frame, a maximum operating current of 1200 Amps (maximum) and 800 Amps (minimum), and an electronic LSIG trip unit. At a frequency range of 50 to 60 Hertz, the circuit breaker has a capacity of 100 kAIC at 240 Volts AC, 65 kAIC at 480 Volts AC, and 35 kAIC at 600 Volts AC. The NGH312036E can accommodate a maximum voltage of 690 Volts AC (IEC) and 600 Volts AC (NEMA). Eaton molded-case circuit breakers with an NG frame size have 750 Volts AC insulation voltage for the main conducting paths, 690 Volts AC insulation voltage for the main auxiliary circuits, and 8 kilovolts rated inputs withstand voltage for the main conducting paths.

Additionally, the NGH312036E Eaton Cutler-Hammer circuit breaker has a 4 kilovolts rated impulse for the auxiliary circuits. Having an NG frame, the NGH312036E has flat bar terminals which accommodate a torque of 50 N-m. When circuit breakers with the NG frame size like the NGH312036E are used for plant protection or as isolating circuit breakers, they have a power loss of between 87 and 210 Watts. The trip unit for the NGH312036E Eaton circuit breaker is factory installed. The circuit breaker can be installed in individual enclosures, switchgear, feeder pillars, panelboards, and bus bar trunking tap-offs. The rated operating temperature for the NGH312036E is a maximum of 70 degrees Celsius and a minimum of -20 degrees Celsius.

Repairs
Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your NGH312036E. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your NGH312036E. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

PDF