NGS308033E
Warranty: | 1 year DO Supply Warranty Included |
Shipping: | Worldwide shipping via DHL, UPS, Fedex, and TNT |
Repairs: | We offer repair service for the NGS308033E. |
Exchange: | Exchange credit for your defective unit available. |
Part Number/Catalog No. | NGS308033E |
Product Type | Molded Case Circuit Breaker |
Frame | NG |
kAIC @ 480 VAC | 50 |
Poles | 3 |
Amps | 80 |
Trip Unit | 310+ Electronic LS |
Terminations | Imperial tapped line/load conductor |
Max. Rated Current | 1200 A |
Main Conducting Paths | 750 VAC |
Max. Switching Frequency | 60 1/h |
Rated Making Capacity | 20 A |
Max. Opening Time | 62 ms |
Rated Operational Voltage | 600 V |
Part Number/Catalog No. | NGS308033E |
Product Type | Molded Case Circuit Breaker |
Frame | NG |
kAIC @ 480 VAC | 50 |
Poles | 3 |
Amps | 80 |
Trip Unit | 310+ Electronic LS |
Terminations | Imperial tapped line/load conductor |
Max. Rated Current | 1200 A |
Main Conducting Paths | 750 VAC |
Max. Switching Frequency | 60 1/h |
Rated Making Capacity | 20 A |
Max. Opening Time | 62 ms |
Rated Operational Voltage | 600 V |
The NGS308033E is a 690 Volts AC standard molded case circuit breaker from Eaton Cutler-Hammer. The circuit breaker has 800 Amps of rated current and 3 poles. The NGS308033E measures 9 x 16 x 6 inches. The circuit breaker uses an NG-frame type, it has an adjustable long delay pickup, and it is HACR rated. This NGS308033E contains an imperial tapped line and load conductors and it belongs to Series G of the molded case circuit breakers. The NGS308033E is UL and CSA listed. The NGS308033E Eaton circuit breaker has an interrupt capacity of 85 kAIC at 240 Volts AC, 50 kAIC at 480 Volts AC, and 25 kAIC at 600 Volts AC.
The net weight for the NGS308033E stands at 47 pounds while the trip unit for the circuit breaker is a Digitrip 310+ Electronic LS. The conducting paths for the NGS308033E have 750 Volts AC insulation voltage, and there are 690 Volts AC insulation voltage for the auxiliary circuits, and an 8 kiloVolts rated impulse withstand voltage for the main conducting paths while the auxiliary circuits have an impulse withstand voltage of 4-kiloVolts. The Cutler-Hammer NGS308033E is 80% rated. Also, the circuit breaker is factory-sealed, making field installations of internal components impossible. The NGS308033E, having an NG-frame, accommodates external accessories like base mounting hardware, interphase barriers, a key interlock kit, an electrical operator, a handle extension, and a trip LED module, among others. Some of these external accessories are pole specific for proper functioning.
Type | Lead Time | Price | Action |
---|---|---|---|
Repair Service | 2-4 weeks | Ask | ![]() |
Our highly skilled technicians can repair your NGS308033E. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.
Size | |
Input Type | |
Panel Cutout Height | in mm |
Panel Cutout Width | in mm |
Terminal Height | in mm |
Terminal Width | in mm |
Terminal Overall Depth | in mm |
Terminal Mounted Depth | in mm |
Part Number/Catalog No. | NGS308033E |
Product Type | Molded Case Circuit Breaker |
Frame | NG |
kAIC @ 480 VAC | 50 |
Poles | 3 |
Amps | 80 |
Trip Unit | 310+ Electronic LS |
Terminations | Imperial tapped line/load conductor |
Max. Rated Current | 1200 A |
Main Conducting Paths | 750 VAC |
Max. Switching Frequency | 60 1/h |
Rated Making Capacity | 20 A |
Max. Opening Time | 62 ms |
Rated Operational Voltage | 600 V |
Part Number/Catalog No. | NGS308033E |
Product Type | Molded Case Circuit Breaker |
Frame | NG |
kAIC @ 480 VAC | 50 |
Poles | 3 |
Amps | 80 |
Trip Unit | 310+ Electronic LS |
Terminations | Imperial tapped line/load conductor |
Max. Rated Current | 1200 A |
Main Conducting Paths | 750 VAC |
Max. Switching Frequency | 60 1/h |
Rated Making Capacity | 20 A |
Max. Opening Time | 62 ms |
Rated Operational Voltage | 600 V |
The NGS308033E is a 690 Volts AC standard molded case circuit breaker from Eaton Cutler-Hammer. The circuit breaker has 800 Amps of rated current and 3 poles. The NGS308033E measures 9 x 16 x 6 inches. The circuit breaker uses an NG-frame type, it has an adjustable long delay pickup, and it is HACR rated. This NGS308033E contains an imperial tapped line and load conductors and it belongs to Series G of the molded case circuit breakers. The NGS308033E is UL and CSA listed. The NGS308033E Eaton circuit breaker has an interrupt capacity of 85 kAIC at 240 Volts AC, 50 kAIC at 480 Volts AC, and 25 kAIC at 600 Volts AC.
The net weight for the NGS308033E stands at 47 pounds while the trip unit for the circuit breaker is a Digitrip 310+ Electronic LS. The conducting paths for the NGS308033E have 750 Volts AC insulation voltage, and there are 690 Volts AC insulation voltage for the auxiliary circuits, and an 8 kiloVolts rated impulse withstand voltage for the main conducting paths while the auxiliary circuits have an impulse withstand voltage of 4-kiloVolts. The Cutler-Hammer NGS308033E is 80% rated. Also, the circuit breaker is factory-sealed, making field installations of internal components impossible. The NGS308033E, having an NG-frame, accommodates external accessories like base mounting hardware, interphase barriers, a key interlock kit, an electrical operator, a handle extension, and a trip LED module, among others. Some of these external accessories are pole specific for proper functioning.
Type | Lead Time | Price | Action |
---|---|---|---|
Repair Service | 2-4 weeks | Ask | ![]() |
Our highly skilled technicians can repair your NGS308033E. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.
Type | Lead Time | Price | Action |
---|---|---|---|
Repair Service | 2-4 weeks | Ask | ![]() |
Our highly skilled technicians can repair your NGS308033E. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.