RGH316033E

Description: The Eaton RGH316033E Molded Case Circuit Breaker operates with 3 Poles and 1600 Amps. The module also has a 310+ Electronic LS Trip Unit and 8 kV Main Conducting Paths.
Rated 4.5 with 6 reviews
top legal disclaimer
top legal disclaimer

credit cards accepted
better business bureau

Available Now

Submit RFQ for RGH316033E

Add more parts to quote

Description: The Eaton RGH316033E Molded Case Circuit Breaker operates with 3 Poles and 1600 Amps. The module also has a 310+ Electronic LS Trip Unit and 8 kV Main Conducting Paths.

Warranty: 1 year DO Supply Warranty Included
Shipping: Worldwide shipping via DHL, UPS, Fedex, and TNT
Repairs: We offer repair service for the RGH316033E.
Exchange: Exchange credit for your defective unit available.

To Speak to a sales representative for pricing & lead time:

phone

International
919-205-4392

Rated 4.5 with 6 reviews

    Technical Specifications for RGH316033E

Part Number/Catalog No.RGH316033E
Product TypeMolded Case Circuit Breaker
kAIC @ 480VAC65
Amps1600
Poles3
Trip Unit310+ Electronic LS
TerminationsImperial Tapped Line/Load Conductor
Max. Rated Current2500 A
Main Conducting Paths8 kV
Endurance3,000 Operating Cycles
Max. Switching Frequency60 1/h
Rated Making Capacity20 A
Rated Operational Voltage125/250 V
Power Consumption @ 24 Vac612 VA
Max. Opening Time62 ms
Part Number/Catalog No.RGH316033E
Product TypeMolded Case Circuit Breaker
kAIC @ 480VAC65
Amps1600
Poles3
Trip Unit310+ Electronic LS
TerminationsImperial Tapped Line/Load Conductor
Max. Rated Current2500 A
Main Conducting Paths8 kV
Endurance3,000 Operating Cycles
Max. Switching Frequency60 1/h
Rated Making Capacity20 A
Rated Operational Voltage125/250 V
Power Consumption @ 24 Vac612 VA
Max. Opening Time62 ms
s

About RGH316033E

The Eaton RGH316033E is a Series G electronic circuit breaker. The RGH316033E is a complete circuit breaker rated at 1600 Amps. It is rated for 125 kiloamps interrupt capacity at 240 Volts AC, 65 kiloamps interrupt capacity at 480 Volts AC, and for 50 kiloamps interrupt capacity at 600 Volts AC. The RGH316033E has three poles, it is rated for 50 and 60 Hertz frequency and it uses a Digitrip 310+ electronic LS trip unit. The insulation voltage rating for the conducting paths is 750 Volts AC and for the auxiliary circuits, it is 690 Volts AC. The impulses withstand voltage rating for the conducting paths is 8 kilovolts. The imperial tapped load and line terminals are included with the circuit breaker. A major advantage of the RGH316033E is that trip settings can be made through the electronic trip unit and therefore DIP switches are not required.

Other features of the circuit breaker include UL ratings, an undervoltage release, a shunt trip, interlocks, a bell alarm, an auxiliary switch, draw out cassettes, and a handle mechanism. Features of the trip unit include an adjustable long-time/short-time delay, a status indicator, a trip push button, and a test port which can be used to interface with a test kit, an ammeter, and an LED module for the cause of the trip. The installation and maintenance of the RGH316033E should only be performed by trained and qualified personnel. Power to the circuit breaker should be disconnected before any maintenance activity is performed. Dimensions of the R-frame RGH316033E are 15.5 x 15.5 x 9.75 inches. The weight of the circuit breaker is 102 pounds.

Repair Services for RGH316033E

Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your RGH316033E. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Dimensions For RGH316033E

Size
Input Type
Panel Cutout Height in mm
Panel Cutout Width in mm
Terminal Height in mm
Terminal Width in mm
Terminal Overall Depth in mm
Terminal Mounted Depth in mm

Dimensions For RGH316033E

Resolutions For RGH316033E

Technical Specifications
Part Number/Catalog No.RGH316033E
Product TypeMolded Case Circuit Breaker
kAIC @ 480VAC65
Amps1600
Poles3
Trip Unit310+ Electronic LS
TerminationsImperial Tapped Line/Load Conductor
Max. Rated Current2500 A
Main Conducting Paths8 kV
Endurance3,000 Operating Cycles
Max. Switching Frequency60 1/h
Rated Making Capacity20 A
Rated Operational Voltage125/250 V
Power Consumption @ 24 Vac612 VA
Max. Opening Time62 ms
Part Number/Catalog No.RGH316033E
Product TypeMolded Case Circuit Breaker
kAIC @ 480VAC65
Amps1600
Poles3
Trip Unit310+ Electronic LS
TerminationsImperial Tapped Line/Load Conductor
Max. Rated Current2500 A
Main Conducting Paths8 kV
Endurance3,000 Operating Cycles
Max. Switching Frequency60 1/h
Rated Making Capacity20 A
Rated Operational Voltage125/250 V
Power Consumption @ 24 Vac612 VA
Max. Opening Time62 ms
About

The Eaton RGH316033E is a Series G electronic circuit breaker. The RGH316033E is a complete circuit breaker rated at 1600 Amps. It is rated for 125 kiloamps interrupt capacity at 240 Volts AC, 65 kiloamps interrupt capacity at 480 Volts AC, and for 50 kiloamps interrupt capacity at 600 Volts AC. The RGH316033E has three poles, it is rated for 50 and 60 Hertz frequency and it uses a Digitrip 310+ electronic LS trip unit. The insulation voltage rating for the conducting paths is 750 Volts AC and for the auxiliary circuits, it is 690 Volts AC. The impulses withstand voltage rating for the conducting paths is 8 kilovolts. The imperial tapped load and line terminals are included with the circuit breaker. A major advantage of the RGH316033E is that trip settings can be made through the electronic trip unit and therefore DIP switches are not required.

Other features of the circuit breaker include UL ratings, an undervoltage release, a shunt trip, interlocks, a bell alarm, an auxiliary switch, draw out cassettes, and a handle mechanism. Features of the trip unit include an adjustable long-time/short-time delay, a status indicator, a trip push button, and a test port which can be used to interface with a test kit, an ammeter, and an LED module for the cause of the trip. The installation and maintenance of the RGH316033E should only be performed by trained and qualified personnel. Power to the circuit breaker should be disconnected before any maintenance activity is performed. Dimensions of the R-frame RGH316033E are 15.5 x 15.5 x 9.75 inches. The weight of the circuit breaker is 102 pounds.

Repairs
Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your RGH316033E. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your RGH316033E. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

PDF