RGH320032E

RGH320032E

Description: The Eaton RGH320032E Molded Case Circuit Breaker operates with 3 Poles and 2000 Amps. The module also has a 310+ Electronic LSI Trip Unit and 8 kV Main Conducting Paths.
Rated 4.6 with 8 reviews
top legal disclaimer
top legal disclaimer

credit cards accepted
better business bureau

Available Now

Submit RFQ for RGH320032E

Add more parts to quote

Description: The Eaton RGH320032E Molded Case Circuit Breaker operates with 3 Poles and 2000 Amps. The module also has a 310+ Electronic LSI Trip Unit and 8 kV Main Conducting Paths.

Warranty: 1 year DO Supply Warranty Included
Shipping: Worldwide shipping via DHL, UPS, Fedex, and TNT
Repairs: We offer repair service for the RGH320032E.
Exchange: Exchange credit for your defective unit available.

To Speak to a sales representative for pricing & lead time:

phone

International
919-205-4392

Rated 4.6 with 8 reviews

    Technical Specifications for RGH320032E

Part Number/Catalog No.RGH320032E
Product TypeMolded Case Circuit Breaker
kAIC @ 480VAC65
Amps2000
Poles3
Trip Unit310+ Electronic LSI
TerminationsImperial Tapped Line/Load Conductor
Max. Rated Current2500 A
Main Conducting Paths8 kV
Endurance3,000 Operating Cycles
Max. Switching Frequency60 1/h
Rated Making Capacity20 A
Rated Operational Voltage125/250 V
Power Consumption @ 24 Vac612 VA
Max. Opening Time62 ms
Part Number/Catalog No.RGH320032E
Product TypeMolded Case Circuit Breaker
kAIC @ 480VAC65
Amps2000
Poles3
Trip Unit310+ Electronic LSI
TerminationsImperial Tapped Line/Load Conductor
Max. Rated Current2500 A
Main Conducting Paths8 kV
Endurance3,000 Operating Cycles
Max. Switching Frequency60 1/h
Rated Making Capacity20 A
Rated Operational Voltage125/250 V
Power Consumption @ 24 Vac612 VA
Max. Opening Time62 ms
s

About RGH320032E

The 2000 Amp rated RGH320032E from Eaton is an RG type Series G circuit breaker with an RG frame. It is well suited for reverse feed applications. The RGH320032E is an 80% rated circuit breaker. The interrupt capacity specifications for the RGH320032E include a 50 kiloamp interrupting capacity at 600 Volts AC, a 65 kiloamp interrupting capacity at 480 Volts AC, and a 125 kiloamp interrupting capacity at 240 Volts AC. The RGH320032E is a three-pole circuit breaker with imperial line/load terminals. The trip module on the RGH320032E is an electronic LSI trip (Digitrip 310 RMS). Since extremely high voltages and currents are present in electrical systems, the RGH320032E should only be installed or serviced when it is not energized. Failure to follow this recommendation can result in serious injury or even death.

For reverse feed applications, special attention is required to ensure that voltages are not present when the RGH320032E is being serviced. Solvents and cleaning agents used to service the circuit breaker should be suitable for this purpose (some commercial solvents are known to cause damage to circuit breaker components). Maintenance or installation activities should be carried out by trained and experienced technicians. The RGH320032E should be inspected periodically. During an inspection, any dirt, grease, and soot should be removed. The circuit breaker should be checked for cracks and discoloration. Breakers with severe discoloration or cracks should be replaced. The RGH320032E has dimensions of about 406 x 393 x 247 millimeters. The approximate weight of the RGH320032E is 102 pounds.

Repair Services for RGH320032E

Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your RGH320032E. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Dimensions For RGH320032E

Size
Input Type
Panel Cutout Height in mm
Panel Cutout Width in mm
Terminal Height in mm
Terminal Width in mm
Terminal Overall Depth in mm
Terminal Mounted Depth in mm

Dimensions For RGH320032E

Resolutions For RGH320032E

Technical Specifications
Part Number/Catalog No.RGH320032E
Product TypeMolded Case Circuit Breaker
kAIC @ 480VAC65
Amps2000
Poles3
Trip Unit310+ Electronic LSI
TerminationsImperial Tapped Line/Load Conductor
Max. Rated Current2500 A
Main Conducting Paths8 kV
Endurance3,000 Operating Cycles
Max. Switching Frequency60 1/h
Rated Making Capacity20 A
Rated Operational Voltage125/250 V
Power Consumption @ 24 Vac612 VA
Max. Opening Time62 ms
Part Number/Catalog No.RGH320032E
Product TypeMolded Case Circuit Breaker
kAIC @ 480VAC65
Amps2000
Poles3
Trip Unit310+ Electronic LSI
TerminationsImperial Tapped Line/Load Conductor
Max. Rated Current2500 A
Main Conducting Paths8 kV
Endurance3,000 Operating Cycles
Max. Switching Frequency60 1/h
Rated Making Capacity20 A
Rated Operational Voltage125/250 V
Power Consumption @ 24 Vac612 VA
Max. Opening Time62 ms
About

The 2000 Amp rated RGH320032E from Eaton is an RG type Series G circuit breaker with an RG frame. It is well suited for reverse feed applications. The RGH320032E is an 80% rated circuit breaker. The interrupt capacity specifications for the RGH320032E include a 50 kiloamp interrupting capacity at 600 Volts AC, a 65 kiloamp interrupting capacity at 480 Volts AC, and a 125 kiloamp interrupting capacity at 240 Volts AC. The RGH320032E is a three-pole circuit breaker with imperial line/load terminals. The trip module on the RGH320032E is an electronic LSI trip (Digitrip 310 RMS). Since extremely high voltages and currents are present in electrical systems, the RGH320032E should only be installed or serviced when it is not energized. Failure to follow this recommendation can result in serious injury or even death.

For reverse feed applications, special attention is required to ensure that voltages are not present when the RGH320032E is being serviced. Solvents and cleaning agents used to service the circuit breaker should be suitable for this purpose (some commercial solvents are known to cause damage to circuit breaker components). Maintenance or installation activities should be carried out by trained and experienced technicians. The RGH320032E should be inspected periodically. During an inspection, any dirt, grease, and soot should be removed. The circuit breaker should be checked for cracks and discoloration. Breakers with severe discoloration or cracks should be replaced. The RGH320032E has dimensions of about 406 x 393 x 247 millimeters. The approximate weight of the RGH320032E is 102 pounds.

Repairs
Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your RGH320032E. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your RGH320032E. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

PDF