RGH320036E

RGH320036E

Description: The Eaton RGH320036E Molded Case Circuit Breaker operates with 3 Poles and 2000 Amps. The module also has a 310+ Electronic LSIG Trip Unit and 8 kV Main Conducting Paths.
Rated 4.5 with 19 reviews
top legal disclaimer
top legal disclaimer

credit cards accepted
better business bureau

Available Now

Submit RFQ for RGH320036E

Add more parts to quote

Description: The Eaton RGH320036E Molded Case Circuit Breaker operates with 3 Poles and 2000 Amps. The module also has a 310+ Electronic LSIG Trip Unit and 8 kV Main Conducting Paths.

Warranty: 1 year DO Supply Warranty Included
Shipping: Worldwide shipping via DHL, UPS, Fedex, and TNT
Repairs: We offer repair service for the RGH320036E.
Exchange: Exchange credit for your defective unit available.

To Speak to a sales representative for pricing & lead time:

phone

International
919-205-4392

Rated 4.5 with 19 reviews

    Technical Specifications for RGH320036E

Part Number/Catalog No.RGH320036E
Product TypeMolded Case Circuit Breaker
kAIC @ 480VAC65
Amps2000
Poles3
Trip Unit310+ Electronic LSIG
TerminationsImperial Tapped Line/Load Conductor
Max. Rated Current2500 A
Main Conducting Paths8 kV
Endurance3,000 Operating Cycles
Max. Switching Frequency60 1/hour
Rated Making Capacity20 A
Rated Operational Voltage125 to 250 Volts
Power Consumption @ 24 Vac612 VA
Max. Opening Time62 milliseconds
Part Number/Catalog No.RGH320036E
Product TypeMolded Case Circuit Breaker
kAIC @ 480VAC65
Amps2000
Poles3
Trip Unit310+ Electronic LSIG
TerminationsImperial Tapped Line/Load Conductor
Max. Rated Current2500 A
Main Conducting Paths8 kV
Endurance3,000 Operating Cycles
Max. Switching Frequency60 1/hour
Rated Making Capacity20 A
Rated Operational Voltage125 to 250 Volts
Power Consumption @ 24 Vac612 VA
Max. Opening Time62 milliseconds
s

About RGH320036E

The RGH320036E is a 3-Pole Type RGH Series-G Molded Case Circuit Breaker manufactured by Eaton. It features a Digitrip 310+ Electronic LSIG trip unit and is rated at 2000 Amperes with a 690 Volts AC maximum operating voltage, 70 kAIC at 415 Volts AC, and 65 kAIC at 480 Volts AC. Like all R-frame circuit breakers, the RGH320036E breaker is suitable for reverse feed applications and is ideal for multipurpose applications in three-phase systems that require short circuit protection or overload protection. The RGH320036E circuit breaker includes a trip unit, adjustable rating plug, and terminals on its line and load sides. Its toggle type switch makes for easy operation and operating status indication and it's 310+ Electronic trip unit provides true RMS sensing to improve the accuracy and effectiveness of its protective capability while minimizing the possibility or nuisance trips.

The RGH320036E circuit breaker features a glass-polyester casing that prevents the growth of fungus and repels moisture. It also has an adjustable short delay pickup with fixed short delay time, adjustable long delay pickup, adjustable ground fault pickup, and an adjustable long delay pickup. Eaton’s molded case circuit breaker accessories (internal and external) can be easily adapted to the RGH320036E breaker to improve its functionality including remote monitoring, resetting, and operation. Its trip unit features an integrated switch that can be used to modify its continuous current rating without changing its rating plug and the circuit breaker itself can be mounted on surface panels or enclosed areas depending on the user/machine requirement.

Repair Services for RGH320036E

Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your RGH320036E. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Dimensions For RGH320036E

Size
Input Type
Panel Cutout Height in mm
Panel Cutout Width in mm
Terminal Height in mm
Terminal Width in mm
Terminal Overall Depth in mm
Terminal Mounted Depth in mm

Dimensions For RGH320036E

Resolutions For RGH320036E

Technical Specifications
Part Number/Catalog No.RGH320036E
Product TypeMolded Case Circuit Breaker
kAIC @ 480VAC65
Amps2000
Poles3
Trip Unit310+ Electronic LSIG
TerminationsImperial Tapped Line/Load Conductor
Max. Rated Current2500 A
Main Conducting Paths8 kV
Endurance3,000 Operating Cycles
Max. Switching Frequency60 1/hour
Rated Making Capacity20 A
Rated Operational Voltage125 to 250 Volts
Power Consumption @ 24 Vac612 VA
Max. Opening Time62 milliseconds
Part Number/Catalog No.RGH320036E
Product TypeMolded Case Circuit Breaker
kAIC @ 480VAC65
Amps2000
Poles3
Trip Unit310+ Electronic LSIG
TerminationsImperial Tapped Line/Load Conductor
Max. Rated Current2500 A
Main Conducting Paths8 kV
Endurance3,000 Operating Cycles
Max. Switching Frequency60 1/hour
Rated Making Capacity20 A
Rated Operational Voltage125 to 250 Volts
Power Consumption @ 24 Vac612 VA
Max. Opening Time62 milliseconds
About

The RGH320036E is a 3-Pole Type RGH Series-G Molded Case Circuit Breaker manufactured by Eaton. It features a Digitrip 310+ Electronic LSIG trip unit and is rated at 2000 Amperes with a 690 Volts AC maximum operating voltage, 70 kAIC at 415 Volts AC, and 65 kAIC at 480 Volts AC. Like all R-frame circuit breakers, the RGH320036E breaker is suitable for reverse feed applications and is ideal for multipurpose applications in three-phase systems that require short circuit protection or overload protection. The RGH320036E circuit breaker includes a trip unit, adjustable rating plug, and terminals on its line and load sides. Its toggle type switch makes for easy operation and operating status indication and it's 310+ Electronic trip unit provides true RMS sensing to improve the accuracy and effectiveness of its protective capability while minimizing the possibility or nuisance trips.

The RGH320036E circuit breaker features a glass-polyester casing that prevents the growth of fungus and repels moisture. It also has an adjustable short delay pickup with fixed short delay time, adjustable long delay pickup, adjustable ground fault pickup, and an adjustable long delay pickup. Eaton’s molded case circuit breaker accessories (internal and external) can be easily adapted to the RGH320036E breaker to improve its functionality including remote monitoring, resetting, and operation. Its trip unit features an integrated switch that can be used to modify its continuous current rating without changing its rating plug and the circuit breaker itself can be mounted on surface panels or enclosed areas depending on the user/machine requirement.

Repairs
Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your RGH320036E. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your RGH320036E. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

PDF