RGH325038E

RGH325038E

Description: The Eaton RGH325038E Molded Case Circuit Breaker operates with 3 Poles and 2500 Amps. The module also has a 310+ Electronic LSI w/ Maintenance Mode Trip Unit and 8 kV Main Conducting Paths.
Rated 4.9 with 5 reviews
top legal disclaimer
top legal disclaimer

credit cards accepted
better business bureau

Available Now

Submit RFQ for RGH325038E

Add more parts to quote

Description:

The Eaton RGH325038E Molded Case Circuit Breaker operates with 3 Poles and 2500 Amps. The module also has a 310+ Electronic LSI w/ Maintenance Mode Trip Unit and 8 kV Main Conducting Paths.



Warranty: 1 year DO Supply Warranty Included
Shipping: Worldwide shipping via DHL, UPS, Fedex, and TNT
Repairs: We offer repair service for the RGH325038E.
Exchange: Exchange credit for your defective unit available.

To Speak to a sales representative for pricing & lead time:

phone

International
919-205-4392

Rated 4.9 with 5 reviews

    Technical Specifications for RGH325038E

Part Number/Catalog No.RGH325038E
Product TypeMolded Case Circuit Breaker
kAIC @ 480VAC65
Amps2500
Poles3
Trip Unit310+ Electronic LSI w/ Maintenance Mode
TerminationsImperial Tapped Line/Load Conductor
Max. Rated Current2500 A
Main Conducting Paths8 kV
Endurance3,000 Operating Cycles
Max. Switching Frequency60 1/h
Rated Making Capacity20 A
Rated Operational Voltage125/250 V
Power Consumption @ 24 Vac612 VA
Max. Opening Time62 ms
Part Number/Catalog No.RGH325038E
Product TypeMolded Case Circuit Breaker
kAIC @ 480VAC65
Amps2500
Poles3
Trip Unit310+ Electronic LSI w/ Maintenance Mode
TerminationsImperial Tapped Line/Load Conductor
Max. Rated Current2500 A
Main Conducting Paths8 kV
Endurance3,000 Operating Cycles
Max. Switching Frequency60 1/h
Rated Making Capacity20 A
Rated Operational Voltage125/250 V
Power Consumption @ 24 Vac612 VA
Max. Opening Time62 ms
s

About RGH325038E

The Eaton Cutler-Hammer RGH325038E molded case circuit breaker with an electronic trip unit is a high-performance circuit breaker from the Eaton Series G, Frame RG family of compact yet highly-efficient circuit breakers designed for electrical and mechanical devices for serving a wide range of industrial applications. The RG frame circuit breakers come already assembled with electronic trip units, rating plugs, and terminals, and they are suitable for reverse feed use. The RGH325038E circuit breaker has a carrying current capacity rating of 2500 Amps, and a maximum interrupting capacity of 65 kAIC at 480 Volts AC. It is designed for 600 Volts AC circuits and it can be used in either 5-Hertz or 60-Hertz applications. The RGH325038E circuit breaker, like every Series G circuit breaker with electronic trip units, is rated for 100% operation, and it offers true current sensing that is made possible by microprocessor-controlled settings for accurate and reliable protection.

The RGH325038E circuit breaker offers adjustable short time delay and instantaneous settings, and it also offers selectable long time delay settings with a time range from 2 to 24 seconds. It features the Arcflash Reduction Maintenance Mode which improves the users’ safety by providing an accelerated instantaneous trip to reduce the arc flash. The RGH325038E circuit breaker has a thermal memory that records trip sequences and uses the data to predict a long time delay sequence to protect the system for overheating. It has a 3-pole design and it comes with copper/Aluminum line and load side terminals rated for 100% operating capacity. The RGH325038E circuit breaker has an ambient operating temperature range of -20 to 70 degrees Celsius and it weighs approximately 61.2 kilograms.

Repair Services for RGH325038E

Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your RGH325038E. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Dimensions For RGH325038E

Size
Input Type
Panel Cutout Height in mm
Panel Cutout Width in mm
Terminal Height in mm
Terminal Width in mm
Terminal Overall Depth in mm
Terminal Mounted Depth in mm

Dimensions For RGH325038E

Resolutions For RGH325038E

Technical Specifications
Part Number/Catalog No.RGH325038E
Product TypeMolded Case Circuit Breaker
kAIC @ 480VAC65
Amps2500
Poles3
Trip Unit310+ Electronic LSI w/ Maintenance Mode
TerminationsImperial Tapped Line/Load Conductor
Max. Rated Current2500 A
Main Conducting Paths8 kV
Endurance3,000 Operating Cycles
Max. Switching Frequency60 1/h
Rated Making Capacity20 A
Rated Operational Voltage125/250 V
Power Consumption @ 24 Vac612 VA
Max. Opening Time62 ms
Part Number/Catalog No.RGH325038E
Product TypeMolded Case Circuit Breaker
kAIC @ 480VAC65
Amps2500
Poles3
Trip Unit310+ Electronic LSI w/ Maintenance Mode
TerminationsImperial Tapped Line/Load Conductor
Max. Rated Current2500 A
Main Conducting Paths8 kV
Endurance3,000 Operating Cycles
Max. Switching Frequency60 1/h
Rated Making Capacity20 A
Rated Operational Voltage125/250 V
Power Consumption @ 24 Vac612 VA
Max. Opening Time62 ms
About

The Eaton Cutler-Hammer RGH325038E molded case circuit breaker with an electronic trip unit is a high-performance circuit breaker from the Eaton Series G, Frame RG family of compact yet highly-efficient circuit breakers designed for electrical and mechanical devices for serving a wide range of industrial applications. The RG frame circuit breakers come already assembled with electronic trip units, rating plugs, and terminals, and they are suitable for reverse feed use. The RGH325038E circuit breaker has a carrying current capacity rating of 2500 Amps, and a maximum interrupting capacity of 65 kAIC at 480 Volts AC. It is designed for 600 Volts AC circuits and it can be used in either 5-Hertz or 60-Hertz applications. The RGH325038E circuit breaker, like every Series G circuit breaker with electronic trip units, is rated for 100% operation, and it offers true current sensing that is made possible by microprocessor-controlled settings for accurate and reliable protection.

The RGH325038E circuit breaker offers adjustable short time delay and instantaneous settings, and it also offers selectable long time delay settings with a time range from 2 to 24 seconds. It features the Arcflash Reduction Maintenance Mode which improves the users’ safety by providing an accelerated instantaneous trip to reduce the arc flash. The RGH325038E circuit breaker has a thermal memory that records trip sequences and uses the data to predict a long time delay sequence to protect the system for overheating. It has a 3-pole design and it comes with copper/Aluminum line and load side terminals rated for 100% operating capacity. The RGH325038E circuit breaker has an ambient operating temperature range of -20 to 70 degrees Celsius and it weighs approximately 61.2 kilograms.

Repairs
Type Lead Time Price Action