1321-3RA45-B

1321-3RA45-B

Description: The Allen-Bradley 1321-3RA45-B line reactor is a 3-phase line reactor that can be used at both the input and output sides of different kinds of equipment, including AC drives and motors. It belongs to the 1321 series power conditioning equipment product line from Allen-Bradley. The rated inductance and fundamental current for the 1321-3RA45-B are 0.7 Millihenry and 45 Amps, respectively.
Rated 4.6 with 15 reviews
top legal disclaimer
top legal disclaimer

credit cards accepted
better business bureau

Available Now

Submit RFQ for 1321-3RA45-B

Add more parts to quote

Description:

The Allen-Bradley 1321-3RA45-B line reactor is a 3-phase line reactor that can be used at both the input and output sides of different kinds of equipment, including AC drives and motors. It belongs to the 1321 series power conditioning equipment product line from Allen-Bradley. The rated inductance and fundamental current for the 1321-3RA45-B are 0.7 Millihenry and 45 Amps, respectively.



Warranty: 1 year DO Supply Warranty Included
Shipping: Worldwide shipping via DHL, UPS, Fedex, and TNT
Repairs: We offer repair service for the 1321-3RA45-B.
Exchange: Exchange credit for your defective unit available.

To Speak to a sales representative for pricing & lead time:

phone

International
919-205-4392

Rated 4.6 with 15 reviews

    Technical Specifications for 1321-3RA45-B

BrandAllen-Bradley / Rockwell Automation
Series1321 Power Products
Part Number1321-3RA45-B
Product typeLine reactor
PhaseThree-phase
Inductance0.7 Millihenry
Fundamental current45 Amps
Peak voltage 690 Volts AC
Peak ambient temperature40 degrees Celsius
EnclosureIP11
Peak switching frequency20 kilohertz
Termination85 Amps rated terminal blocks
Max / min wire size4 / 18 AWG
BrandAllen-Bradley / Rockwell Automation
Series1321 Power Products
Part Number1321-3RA45-B
Product typeLine reactor
PhaseThree-phase
Inductance0.7 Millihenry
Fundamental current45 Amps
Peak voltage 690 Volts AC
Peak ambient temperature40 degrees Celsius
EnclosureIP11
Peak switching frequency20 kilohertz
Termination85 Amps rated terminal blocks
Max / min wire size4 / 18 AWG
s

About 1321-3RA45-B

The Allen-Bradley 1321-3RA45-B line reactor is a 3-phase line reactor that can be used at both the input and output sides of equipment, including AC drives and motors. It belongs to the 1321 power conditioning equipment product line from Allen-Bradley. The rated inductance and fundamental current levels for the 1321-3RA45-B line reactor are 0.7 Millihenry and 45 Amps, respectively. The inductor is enclosed inside an IP 11 rated enclosure which is made of sheet steel which complies with the NEMA/UL specifications. For termination, 85 Amps rated terminal blocks are supplied with the 1321-3RA45-B line reactor. Allen-Bradley recommends 20 pounds on an inch of peak torque and 4 18 AWG as the maximum/minimum wire sizes. The 1321-3RA45-B line reactor complies with the CE, UL 508, and SCA C22.2 Class N200C standards.

 

The 1321 series line reactors are available with 1.5%, 3%, and 5% impedance ratings based on the fundamental current ratings. The DV/DT protection on the line reactors complies with the NEMA MG-1 part 31. The overload ratings for 1321-3RA45-B line reactors are 300% of the fundamental current for a time duration of 30 minutes and 200% of the fundamental current for a time duration of 1 minute. The electrical specifications for the 1321-3RA45-B line reactor include 690 Volts AC peak rated voltage, 20-kilohertz peak switching frequency, a 135 degrees Celsius temperature rise, and 3000 Volts RMS dielectric strength. The environmental specifications include 3280 feet peak altitude and 40 degrees Celsius peak ambient temperature. The typical inductance curve is 100% at a 100% current rating, 150% at a 150% current rating, and 50% at a 350% current rating. The Allen-Bradley 1321 series line reactors provide compensation against high frequencies and other currents caused by harmonics.

Repair Services for 1321-3RA45-B

Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your 1321-3RA45-B. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Dimensions For 1321-3RA45-B

Size
Input Type
Panel Cutout Height in mm
Panel Cutout Width in mm
Terminal Height in mm
Terminal Width in mm
Terminal Overall Depth in mm
Terminal Mounted Depth in mm

Dimensions For 1321-3RA45-B

Resolutions For 1321-3RA45-B

Technical Specifications
BrandAllen-Bradley / Rockwell Automation
Series1321 Power Products
Part Number1321-3RA45-B
Product typeLine reactor
PhaseThree-phase
Inductance0.7 Millihenry
Fundamental current45 Amps
Peak voltage 690 Volts AC
Peak ambient temperature40 degrees Celsius
EnclosureIP11
Peak switching frequency20 kilohertz
Termination85 Amps rated terminal blocks
Max / min wire size4 / 18 AWG
BrandAllen-Bradley / Rockwell Automation
Series1321 Power Products
Part Number1321-3RA45-B
Product typeLine reactor
PhaseThree-phase
Inductance0.7 Millihenry
Fundamental current45 Amps
Peak voltage 690 Volts AC
Peak ambient temperature40 degrees Celsius
EnclosureIP11
Peak switching frequency20 kilohertz
Termination85 Amps rated terminal blocks
Max / min wire size4 / 18 AWG
About

The Allen-Bradley 1321-3RA45-B line reactor is a 3-phase line reactor that can be used at both the input and output sides of equipment, including AC drives and motors. It belongs to the 1321 power conditioning equipment product line from Allen-Bradley. The rated inductance and fundamental current levels for the 1321-3RA45-B line reactor are 0.7 Millihenry and 45 Amps, respectively. The inductor is enclosed inside an IP 11 rated enclosure which is made of sheet steel which complies with the NEMA/UL specifications. For termination, 85 Amps rated terminal blocks are supplied with the 1321-3RA45-B line reactor. Allen-Bradley recommends 20 pounds on an inch of peak torque and 4 18 AWG as the maximum/minimum wire sizes. The 1321-3RA45-B line reactor complies with the CE, UL 508, and SCA C22.2 Class N200C standards.

 

The 1321 series line reactors are available with 1.5%, 3%, and 5% impedance ratings based on the fundamental current ratings. The DV/DT protection on the line reactors complies with the NEMA MG-1 part 31. The overload ratings for 1321-3RA45-B line reactors are 300% of the fundamental current for a time duration of 30 minutes and 200% of the fundamental current for a time duration of 1 minute. The electrical specifications for the 1321-3RA45-B line reactor include 690 Volts AC peak rated voltage, 20-kilohertz peak switching frequency, a 135 degrees Celsius temperature rise, and 3000 Volts RMS dielectric strength. The environmental specifications include 3280 feet peak altitude and 40 degrees Celsius peak ambient temperature. The typical inductance curve is 100% at a 100% current rating, 150% at a 150% current rating, and 50% at a 350% current rating. The Allen-Bradley 1321 series line reactors provide compensation against high frequencies and other currents caused by harmonics.

Repairs
Type Lead Time Price Action