Product image is representative; revision or series may vary. Contact us to request a specific version.
The ABB XT5SU340ABFN000XXX, part of the Tmax XT Series, is a molded case circuit breaker designed for robust performance. It supports a rated voltage of 600 Volts AC and has a current rating of 400 Amperes. With three poles for three-phase systems, it can interrupt currents up to 50 kiloamperes at 480 Volts AC and 65 kiloamperes at 240 Volts AC.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | ABB |
|---|---|
| Product Type | Molded Case Circuit Breaker |
| Product Line | Tmax XT Series |
| Part Number | XT5SU340ABFN000XXX |
| UPC | 0 56221022109 |
| Rated Voltage | 600 Volts AC |
| Rated Current | 400 Amperes |
| Number of Poles | 3 poles |
| Interrupting Rating | 50 kiloamperes at 480 Volts AC and 65 kiloamperes at 240 Volts AC |
| Phase Rating | 3-phase |
| System Frequency | 50 to 60 Hertz |
| Type of Trip Unit | Adjustable thermal magnetic trip unit |
| Trip Functions | Long-Time and Instantaneous (LI) |
| Wire Range | 2 to 2/0 American Wire Gauge (AWG) |
| Line Side Terminal Connection | Front terminals without lugs |
| Compatible Wire Type | Copper or aluminum wire |
| Number of Cables Per Lug | 2 cables |
The ABB XT5SU340ABFN000XXX circuit breaker, from the Tmax XT Series, is engineered for efficient circuit protection. It operates at a substantial rated voltage of 600 Volts AC and has a maximum current rating of 400 Amperes. This molded case circuit breaker is configured with three poles, making it suitable for 3-phase systems.
The device is rated to interrupt fault currents of up to 50 kiloamperes at 480 Volts AC, and an impressive 65 kiloamperes at 240 Volts AC, ensuring effective protection in demanding applications. Designed to function efficiently within a frequency range of 50 to 60 Hertz, it utilizes an adjustable thermal magnetic trip unit to safeguard against overload and short-circuit conditions. The trip unit supports long-time and instantaneous trip functions, giving flexibility in response to different fault conditions.
Wiring is straightforward with this circuit breaker, accommodating a wire range from 2 to 2/0 AWG, and it accepts both copper and aluminum wiring types. The breaker features front terminals that do not require lugs for connection, allowing for easier installation. Each terminal can accommodate up to two cables, adding to its practicality for various electrical setups.