Product image is representative; revision or series may vary. Contact us to request a specific version.
The Allen Bradley 1336-L4 is a control interface designed for operational versatility. With a maximum input frequency of 63 Hz and a logic type based on TTL contact closures, it allows for effective management of inputs.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Allen Bradley |
|---|---|
| Product Type | Control Interface |
| Product Line | 1336 Adjustable |
| Part Number | 1336-L4 |
| UPC | 662453100623 |
| Weight | 0.25 lbs (0.11 kg) |
| Logic Type | TTL contact closure interface |
| Supply Voltage | 5 V DC |
| Discrete Input Count | 9 configurable discrete inputs |
| Input Frequency | 47 Hz to 63 Hz |
| Input Current | 10 mA |
| Maximum Off-State Voltage | 30V AC |
| Maximum Off-State Current | 2.5 mA |
| Inrush Current | 110 mA |
| Maximum Contact Resistance | ≤ 100 Ω |
| Terminal Torque | 0.8 N·m |
| Terminal Wire Size | 2.1 mm² |
| Input Scan Time | 10 ms |
| Operating Temperature | 0°C to +40 °C |
The Allen Bradley 1336-L4 is classified as a control interface, functioning with a TTL contact closure logic type that ensures reliability in signal management. Operating at a supply voltage of 5 volts DC, this device is engineered for precise applications in industrial settings. It offers nine discrete inputs that can be configured according to user requirements.
Designed to handle input frequencies between 47 Hz and 63 Hz, the 1336-L4 allows for sufficient flexibility while maintaining an input current of 10 mA, ensuring responsive operation. The control interface can manage off-state voltages up to 30 volts AC, with a maximum off-state current rated at 2.5 mA, emphasizing its robustness in control applications. Inrush current measures at 110 mA, ensuring adequate start-up performance.
With a maximum contact resistance of less than or equal to 100 Ω, reliable connections are ensured, which is crucial for circuit integrity. For physical installation, the device requires terminal torque of 0.8 N·m and can accommodate wire sizes of 2.1 mm². The input scan time is set at 10 milliseconds, providing rapid response times for system operations. The operating temperature range for the 1336-L4 is set between 0°C and +40°C, making it suitable for a range of industrial environments.
| Revision Part # | Also known as | |
|---|---|---|
| 1336-L4 Ser A | 1336-L4/A, Series A, Rev A | |
| Don't see your particular revision? Contact us now. | ||