The Allen-Bradley 1336F-B040-AN-EN-HASB-L6 motor control drive is an adjustable frequency drive from the 1336 PLUS II series. The nominal output power rating of the drive is 40 Horsepower. The input voltage range of the 1336F-B040-AN-EN-HASB-L6 drive is 380 to 480 Volts AC.

In Stock
Ships from Raleigh, NC
2 Year DO Supply Warranty
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more
Rockwell Disclaimer: The product is used surplus. DO Supply is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because DO Supply is not an authorized distributor of this product, the Original Manufacturer's warranty does not apply. While many Allen-Bradley PLC products will have firmware already installed, DO Supply makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. DO Supply also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source. DO Supply also makes no representations as to your right to install any such firmware on the product. DO Supply will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Technical specifications for 1336F-B040-AN-EN-HASB-L6

ManufacturerAllen Bradley
Product TypeMotor Control Drive
Product Line1336 PLUS II Drives
Part Number1336F-B040-AN-EN-HASB-L6
Weight85.00 lbs (38.56 kg)
Input Voltage380 to 480 Volts AC
Output Power40 Horsepower
EnclosureOpen
Protection RatingIP 00
Mounting OrientationVertical
HMINone
Control Interface115 Volts AC
Output Frequency0 to 400 Hertz
Maximum Operating Altitude1000 Meters

The Allen-Bradley 1336F-B040-AN-EN-HASB-L6 1336 PLUS II series motor control drive is an adjustable frequency drive. Its full rated output power is 40 Horsepower. This output power rating is valid for 380 to 480 Volts AC 3-phase input voltage. The full rated output power also requires an ambient temperature range between 32 and 122 degrees Fahrenheit, and elevations between 0 and 3300 feet above sea level. The output power rating of the 1336F-B040-AN-EN-HASB-L6 drive will fall below 40 Horsepower if the drive is used at temperatures or elevations outside of those specified by the manufacturer. The 1336F-B040-AN-EN-HASB-L6 drive has an open enclosure with an IP 00 protection rating. The approximate enclosure dimensions are 27.6 x 11.88 x 3.68 inches. The approximate weight of the 1336F-B040-AN-EN-HASB-L6 motor control drive is 85 pounds.

The manual for the Allen-Bradley 1336F-B040-AN-EN-HASB-L6 1336 PLUS II series motor control drive is in English. The control interface module on the drive works at 115 Volts AC. The other slots for optional hardware modules on the drive are vacant, but the drive operators can install 1 optional communication module, 1 HMI module, and 2 analog I/O modules on the drive if necessary. The 1336F-B040-AN-EN-HASB-L6 drive is shipped with a blank plate to cover the opening in the front panel where an HMI module would normally be. Due to the presence of ESD-sensitive drive components, the operators must follow ESD precautions when handling, installing, or servicing the drive. Additionally, all technicians servicing the 1336F-B040-AN-EN-HASB-L6 drive must power it off and wait until the DC capacitors on the bus are fully discharged before beginning any maintenance work. Failure to allow the DC bus capacitors to discharge completely can lead to severe electric shock.