Free UPS Ground on All Orders!
+1 (919) 205-4392
Allen Bradley 1336 1336-B005-ECD-FA2-L1

Product image is representative; revision or series may vary. Contact us to request a specific version.

1336-B005-ECD-FA2-L1

|

The Allen-Bradley/Rockwell Automation 1336-B005-ECD-FA2-L1 AC drive is a Bulletin 1336 adjustable frequency drive. It can use its adjustable frequency to adjust the torque or the speed of an AC motor in a variety of applications. The 1336-B005-ECD-FA2-L1 adjustable frequency drive comes with an interface board and a control panel. Its interface board is a TTL logic contact closure type of interface board that is rated at 5 Volts DC. The 1336-B005-ECD-FA2-L1 adjustable frequency drive’s control panel can be used to start and stop the drive.

Call for an immediate quote
2 Year DO Supply Warranty
Available
Ships from Raleigh, NC
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more
Rockwell Disclaimer: The product is used surplus. DO Supply is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because DO Supply is not an authorized distributor of this product, the Original Manufacturer's warranty does not apply. While many Allen-Bradley PLC products will have firmware already installed, DO Supply makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. DO Supply also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source. DO Supply also makes no representations as to your right to install any such firmware on the product. DO Supply will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Technical specifications for 1336-B005-ECD-FA2-L1

ManufacturerAllen Bradley
Product TypeAdjustable Frequency AC Drive
Product Line1336
Part Number1336-B005-ECD-FA2-L1
Weight33.00 lbs (14.97 kg)
Input Voltage380/415/460V AC
Hz50/60
Phases3
Amps Out9.6
KVA Out @ 380V AC6.3
KVA Out @ 415V AC6.9
KVA Out at 460V AC7.6
Enclosure TypeNEMA Type 4 (IP56)
Enclosure Amp Rating003, 005, 007, or 010
OptionBasic control panel for open or NEMA Type 1 enclosures
Product Lifecycle Status*Discontinued/Obsolete

* The Allen Bradley 1336-B005-ECD-FA2-L1 has been discontinued by the manufacturer, however we specialize in obsolete parts and can likely still supply surplus and/or refurbished replacement 1336-B005-ECD-FA2-L1 units instead of migration.

The Allen Bradley 1336-B005-ECD-FA2-L1 Adjustable Frequency AC Drive is a digital AC drive with direct 3-phase line input connection, which is designed to control the speed of induction motors using Pulse Width Modulated signals, 3-phase output, and an adjustable output frequency. This drive is programmed digitally to achieve precise and repeatedly accurate control, setup and operation, and it is configured using factory supplied control panel option for local control, and control interface option with pre-factory designated command functions. The 1336-B005-ECD-FA2-L1 has an output power rating of 7.3 Kilo Volt-Ampere, with an input current of 9.3 Amperes, and it has an operating voltage range of 380 to 460 Volts AC. It also has a 9.6 Ampere input current rating at 460 Volts, with a 7.6 Kilo Volt-Ampere output power rating, and it has a displacement power factor of 0.95. The 1336-B005-ECD-FA2-L1 is designed to provide a fast acting current limit, and it can regulate the BUS AC/DC voltage for efficient operation. It can also sense ground faults from irregular line input current, and it is fitted with line to line and line to ground wired Metal Oxide Varistor, which provides phase-to-phase and ground fault protection on the drive’s output. This drive has an overload capability, programmable from 50% to 150% of rated output current, and it can provide Class 10 motor overload protection. The 1336-B005-ECD-FA2-L1 can ride through 2 seconds of power outage (dependent on the integrity of user-supplied circuit), and it can also provide protection against any transient voltage up to 5000 Volts. It is programmed by default for Volt per Hertz control, and it uses Pulse Width Modulated output waveform for control. It has an output frequency range, programmable from 0 Hertz (minimum) to 250 Hertz (maximum), and its output voltage is adjustable from 0 to its applied input voltage value. The 1336-B005-ECD-FA2-L1 has a control panel option, which allows for configuration of the drive locally, and it also has a 5 Volt DC Logic control interface board, which provides the drive with basic operation commands. It has a rated ambient range of 0 to + 40 degree Celsius, and it is enclosed with a NEMA type 4 enclosure, which provides protection against water, dust, ice, corrosion, and other external contaminants. The 1336-B005-ECD-FA2-L1 has an approximate weight of 16.5 kilograms, and dimensions of 283 x 477 x 223 millimeters.

Revision Part #Also known as
1336-B005-ECD-FA2-L1 Ser A1336-B005-ECD-FA2-L1/A, Series A, Rev A