Product image is representative; revision or series may vary. Contact us to request a specific version.
The Allen-Bradley 1336-B050-E0G drive is an adjustable frequency AC drive that is designed to control the speed and torque of AC motors in Allen-Bradley PLC systems. It is available through the Allen-Bradley Bulletin 1336 series of adjustable frequency drives. The 1336-B050-E0G adjustable frequency drive supports 380, 415, or 460 Volts AC 3-phase input voltage at 50 to 60 Hertz. It also supports 75 Amps of output current. The 1336-B050-E0G adjustable frequency drive supports a T1 fan transformer that needs to be used to cool the drive down when it operates at high voltage levels.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Allen Bradley |
|---|---|
| Product Type | Adjustable Frequency AC Drive |
| Product Line | 1336 |
| Part Number | 1336-B050-E0G |
| Weight | 90.00 lbs (40.82 kg) |
| Input Voltage | 380/415/460V AC |
| Hz | 50/60 |
| Phases | 3 |
| Amps Out | 75 |
| KVA Out at 380V AC | 49 |
| KVA Out at 415V AC | 54 |
| KVA Out at 460V AC | 60 |
| Enclosure Type | Open style (IP00) |
| Enclosure Amp Rating | 040 or 050 |
| Product Lifecycle Status* | Discontinued/Obsolete |
* The Allen Bradley 1336-B050-E0G has been discontinued by the manufacturer, however we specialize in obsolete parts and can likely still supply surplus and/or refurbished replacement 1336-B050-E0G units instead of migration.
The Allen-Bradley 1336-B050-E0G is a variable frequency drive designed for AC input voltage. The 1336-B050-E0G is a drive from the 1336 drive family. The 1336-B050-E0G operates at following 3-phase AC input voltages: 380, 415, and 460 Volts AC. The range of the input frequency is 50 or 60 Hertz. The isolation transformer or line reactor can be used to reduce the possibility of malfunctioning due to power line abnormalities. If the drive needs to be operated at 380 or 415 Volts AC, then the T1 fan transformer must be used. Failure to do so could lead to a high temperature fault. The current input of the 1336-B050-E0G is 76 Amps. The input power is 50 kVA, 55 kVA, and 61 kVA at 380, 415, and 460 Volts AC, respectively.
The current at the output is rated at 50 Amps for the 1336-B050-E0G. The power output is as follows: 49 kVA at 380 Volts AC, 54 kVA at 415 Volts AC, and 60 kVA at 460 Volts AC. The voltage at the output can vary from 0 to the input voltage. The frequency at the output can be set from a minimum of 0 to a maximum of 250 Hertz. The 1336-B050-E0G is an IP00 Type of open drive. The weight of the drive is 85 pounds and its dimensions are 17.5 x 34.2 x 9.38 inches. Total combined heat dissipation level is 3973 BTU/hour and 205 CFM of airflow is needed to ensure that the drive operates according to specifications. The temperature range for drive operation is from 32 to 122 degrees Fahrenheit. The 1336-B050-E0G can operate at a maximum height of 1000 meters without derating. The shock rating is a maximum of 15G for 11 milliseconds.
| Revision Part # | Also known as | |
|---|---|---|
| 1336-B050-E0G Ser A | 1336-B050-E0G/A, Series A, Rev A | |
| Don't see your particular revision? Contact us now. | ||
The Allen-Bradley 1336-B050-E0G Adjustable Frequency AC Drive operates with a 380/415/460V A Input Voltage, 50/60 Hz, and 3 Phases. The 1336-B050-E0G has 75 Amps Out and a Open style (IP00) Enclosure Type.