Product image is representative; revision or series may vary. Contact us to request a specific version.
The 2094-AM05 Axis Module inverter belongs to the Kinetix 6000 series. It has an internal shunt resistor with a 50 Watt continuous power and a 1400 Watt peak power. This module has a 98% efficiency with a shunt-on rating of 405 Volts DC and a shunt-off rating of 375 Volt DC.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Allen Bradley |
|---|---|
| Category | Drives |
| Product Line | Kinetix 6000 |
| Part Number | 2094-AM05 |
| Weight | 7.00 lbs (3.18 kg) |
| Module Type | Axis Module |
| Efficiency | 0.98 |
| Continuous Current (rms) | 34.6 Anps |
| Continuous Current (0-peak) | 48.9 Amps |
| PWM frequency | 4 kHz |
| Bandwidth Velocity loop | 500 Hertz |
| Internal Shunt Continuous Power | 50 Watts |
| Internal Shunt Peak Power | 1400 Watts |
| Nominal Input Voltage | 325 Volts DC |
| Shunt On | 405 Volts DC |
The Allen-Bradley 2094-AM05 is an axis module for use in the Allen-Bradley Kinetix 6000 drive system. The operating efficiency of the module is affected by very low or very high surrounding temperatures. The 2094-AM05 has a shunt-on voltage rating of 405 Volts DC and a shunt-off voltage rating of 375 Volts DC. The module has a capacitance of 2640 microfarads and capacitive energy absorption of 99 Joules. For efficiency, the 2094-AM05 has a 98% efficiency. The 2094-AM05 has an internal shunt resistor rated at 115 Ohms. The module has 34.6 Amps of continuous current (RMS) and 48.9 Amps continuous current (0-pk). The 2094-AM05 has a root mean square (RMS) peak current of 51.9 Amps. The 0-peak current rating for the module is 73.4 Amps.
The continuous power output rating for the 2094-AM05 is capped at 11.0 KiloWatts. The 2094-AM05 has a shunt-on function rated at 405 Volts DC, and a shunt-off function rated at 375 Volts DC. Note that since the 2094-AM05 is a Kinetix 6000 Axis Module (AM), the rating for its peak current is set during manufacture at 150% of the continuous current. The 2094-AM05 does not support the peak-enhanced feature. The 2094-AM05 should not be transported at an altitude exceeding 3000 meters. During storage, a minimum surrounding temperature must not fall below -40 degrees Celsius and a maximum of 70 degrees Celsius should be maintained. Also, the 2094-AM05 must not be stored or operated in environments that exceed a non-condensing relative humidity of 95%.
| Revision Part # | Also known as | |
|---|---|---|
| 2094-AM05 Ser A | 2094-AM05/A, Series A, Rev A | |
| Don't see your particular revision? Contact us now. | ||