21T-351893-A04

21T-351893-A04

Description: The Allen-Bradley 21T-351893-A04 board is an inverter power board for the LiquiFlo 2.0 AC drives. It is a LiquiFlo 2.0 power module replacement part (for Frame 3 drives only) and it has an output voltage range between 5 and 265 Volts AC and 5 and 125 Volts DC. This content was written and compiled by DO Supply and should not be copied.
Rated 4.5 with 19 reviews

Preowned

Includes a 1-Year DO Supply warranty.

DO Supply is not an authorized distributor for Allen Bradley.

top legal disclaimer
top legal disclaimer

credit cards accepted
better business bureau

Available Now

Submit RFQ for 21T-351893-A04

Add more parts to quote

Description: The Allen-Bradley 21T-351893-A04 board is an inverter power board for the LiquiFlo 2.0 AC drives. It is a LiquiFlo 2.0 power module replacement part (for Frame 3 drives only) and it has an output voltage range between 5 and 265 Volts AC and 5 and 125 Volts DC. This content was written and compiled by DO Supply and should not be copied.

Preowned

Includes a 1-Year DO Supply warranty.

DO Supply is not an authorized distributor for Allen Bradley.

top legal disclaimer
disclaimer
credit cards
better business bureau

Warranty: 1 year DO Supply Warranty Included
Shipping: Worldwide shipping via DHL, UPS, Fedex, and TNT
Repairs: We offer repair service for the 21T-351893-A04.
Exchange: Exchange credit for your defective unit available.
Conditions: We sell preowned surplus and refurbished parts.

To speak to a sales representative for pricing & lead time:


Rated 4.5 with 19 reviews

    Technical Specifications for 21T-351893-A04

BrandAllen-Bradley / Rockwell Automation
SeriesLiquiFlo
Part Number21T-351893-A04
Bulletin Number21T
Output Voltage5 to 265 Volts AC and 5 to 125 Volts DC
Frequency 50/60 Hertz
Agency CertificationsCSA Listed, CE Mark, cUL, UL Listed and UL/CSA Class I Div 2, Groups A, B, C, and D
Storage Temperature-40 to +65 degrees Celsius (-40 to +149 degrees Fahrenheit)
Operating Temperature with an Enclosure0 to 55 degrees Celsius (32 to 131 degrees Fahrenheit)
Operating Temperature without an Enclosure0 to 40 degrees Celsius (32 or 104 degrees Fahrenheit)
BrandAllen-Bradley / Rockwell Automation
SeriesLiquiFlo
Part Number21T-351893-A04
Bulletin Number21T
Output Voltage5 to 265 Volts AC and 5 to 125 Volts DC
Frequency 50/60 Hertz
Agency CertificationsCSA Listed, CE Mark, cUL, UL Listed and UL/CSA Class I Div 2, Groups A, B, C, and D
Storage Temperature-40 to +65 degrees Celsius (-40 to +149 degrees Fahrenheit)
Operating Temperature with an Enclosure0 to 55 degrees Celsius (32 to 131 degrees Fahrenheit)
Operating Temperature without an Enclosure0 to 40 degrees Celsius (32 or 104 degrees Fahrenheit)
s

About 21T-351893-A04

The Allen-Bradley 21T-351893-A04 Kit is a LiquiFlo inverter power board can be installed with the following procedure. First, ensure that every inverter parameter is reset to the default state by configuring the inverter parameter 197 to 1. The 197 parameter value changes to 0 as soon as 1 is typed into the memory. This configuration eliminates fault 100, which is the parameter checksum, and fault 107, which represents the replaced MCB-PB device. Second, reset the operation to the default, which results in fault 48, also referred to as the Params Defaulted setting. Note that this is an information fault only and it will be cleared. If this fault on the drive still exists after the operators attempt to clear it, it is recommended to troubleshoot the board based on the current fault. Third, all the drive parameters should be reprogrammed. When replacing the Allen-Bradley 21T-351893-A04 LiquiFlo inverter power board, drive fault 106, also known as Incompact MCB-PB, may occur. This means that the new inverter power board is incompatible with the earlier inverter control board and it would be best if the users changed the previous control board as well.



 



The Allen-Bradley 21T-351893-A04 inverter power board is a LiquiFlo 2.0 power module replacement parts (for the LiquiFlo Frame 3 size drives only). This inverter power board has conformed to international agency certifications such as the CSA List, CE Mark, cUL and UL List Class I Division 2, Groups A, B, C, and D standards. The 21T-351893-A04 inverter power board is commonly used in applications in the steel industry, power industry, glass industry, and the food processing industry. It has an ambient storage temperature ranging from -40 to +65 degrees Celsius (-40 to +149 degrees Fahrenheit) and an operating temperature range between 0 and 55 degrees Celsius (32 and 131 degrees Fahrenheit) when it is installed inside a NEMA/UL Type 1 enclosure, or an operating temperature range of 0 to 40 degrees Celsius (32 or 104 degrees Fahrenheit) when it is not installed in a NEMA/UL Type 1 enclosure.



Repair Services for 21T-351893-A04

Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your 21T-351893-A04. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Dimensions For 21T-351893-A04

Size
Input Type
Panel Cutout Height in mm
Panel Cutout Width in mm
Terminal Height in mm
Terminal Width in mm
Terminal Overall Depth in mm
Terminal Mounted Depth in mm

Dimensions For 21T-351893-A04

Resolutions For 21T-351893-A04

About

Technical Specifications for 21T-351893-A04

BrandAllen-Bradley / Rockwell Automation
SeriesLiquiFlo
Part Number21T-351893-A04
Bulletin Number21T
Output Voltage5 to 265 Volts AC and 5 to 125 Volts DC
Frequency 50/60 Hertz
Agency CertificationsCSA Listed, CE Mark, cUL, UL Listed and UL/CSA Class I Div 2, Groups A, B, C, and D
Storage Temperature-40 to +65 degrees Celsius (-40 to +149 degrees Fahrenheit)
Operating Temperature with an Enclosure0 to 55 degrees Celsius (32 to 131 degrees Fahrenheit)
Operating Temperature without an Enclosure0 to 40 degrees Celsius (32 or 104 degrees Fahrenheit)
BrandAllen-Bradley / Rockwell Automation
SeriesLiquiFlo
Part Number21T-351893-A04
Bulletin Number21T
Output Voltage5 to 265 Volts AC and 5 to 125 Volts DC
Frequency 50/60 Hertz
Agency CertificationsCSA Listed, CE Mark, cUL, UL Listed and UL/CSA Class I Div 2, Groups A, B, C, and D
Storage Temperature-40 to +65 degrees Celsius (-40 to +149 degrees Fahrenheit)
Operating Temperature with an Enclosure0 to 55 degrees Celsius (32 to 131 degrees Fahrenheit)
Operating Temperature without an Enclosure0 to 40 degrees Celsius (32 or 104 degrees Fahrenheit)

About 21T-351893-A04

The Allen-Bradley 21T-351893-A04 Kit is a LiquiFlo inverter power board can be installed with the following procedure. First, ensure that every inverter parameter is reset to the default state by configuring the inverter parameter 197 to 1. The 197 parameter value changes to 0 as soon as 1 is typed into the memory. This configuration eliminates fault 100, which is the parameter checksum, and fault 107, which represents the replaced MCB-PB device. Second, reset the operation to the default, which results in fault 48, also referred to as the Params Defaulted setting. Note that this is an information fault only and it will be cleared. If this fault on the drive still exists after the operators attempt to clear it, it is recommended to troubleshoot the board based on the current fault. Third, all the drive parameters should be reprogrammed. When replacing the Allen-Bradley 21T-351893-A04 LiquiFlo inverter power board, drive fault 106, also known as Incompact MCB-PB, may occur. This means that the new inverter power board is incompatible with the earlier inverter control board and it would be best if the users changed the previous control board as well.



 



The Allen-Bradley 21T-351893-A04 inverter power board is a LiquiFlo 2.0 power module replacement parts (for the LiquiFlo Frame 3 size drives only). This inverter power board has conformed to international agency certifications such as the CSA List, CE Mark, cUL and UL List Class I Division 2, Groups A, B, C, and D standards. The 21T-351893-A04 inverter power board is commonly used in applications in the steel industry, power industry, glass industry, and the food processing industry. It has an ambient storage temperature ranging from -40 to +65 degrees Celsius (-40 to +149 degrees Fahrenheit) and an operating temperature range between 0 and 55 degrees Celsius (32 and 131 degrees Fahrenheit) when it is installed inside a NEMA/UL Type 1 enclosure, or an operating temperature range of 0 to 40 degrees Celsius (32 or 104 degrees Fahrenheit) when it is not installed in a NEMA/UL Type 1 enclosure.



Repairs
Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your 21T-351893-A04. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your 21T-351893-A04. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

PDF