Product image is representative; revision or series may vary. Contact us to request a specific version.
The 20DD077A0ENNA6CNL model from Allen-Bradley is designed as an adjustable frequency AC drive capable of delivering efficient motor control. Operating at a voltage of 480V AC, this unit supports three-phase systems and can handle a maximum normal-duty current of 77 amps, making it suitable for various industrial applications.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Allen Bradley |
|---|---|
| Product Type | Adjustable Frequency AC Drive |
| Product Line | PowerFlex 700S |
| Part Number | 20DD077A0ENNA6CNL |
| Weight | 32.00 lbs (14.51 kg) |
| Voltage | 480V AC |
| Phases | 3 |
| 480V Input Amps | 77 |
| Enclosure | IP20, NEMA Type 1 |
| Human Interface Machine | Blank Cover |
| Documentation | Quick Start Guide |
| Brake | No |
| Bus Undervoltage Trip | Adjustable |
| Heat Sink Thermistor | Monitored by microprocessor overtemp trip |
| Logic Control Ride-Thru | 0.25 sec., drive not running |
| Power Ride-Thru | 15 milliseconds at full load |
The 20DD077A0ENNA6CNL from Allen-Bradley functions as an adjustable frequency AC drive within the PowerFlex 700S series. This drive is ideal for three-phase applications operating at 480V AC, capable of accommodating a normal-duty current of 77 amps. Configured with a design suited for typical industrial environments, this drive features an enclosure rated at IP20, compliant with NEMA Type 1 specifications. The drive has a blank cover instead of an interface.
It is noteworthy that the drive does not come with a braking feature, but it incorporates an adjustable bus undervoltage trip. This customization allows users to set parameters according to specific application demands. The unit also includes a heat sink thermistor that is actively monitored by a microprocessor, which triggers an overtemperature trip as needed for safety.
In terms of operational resilience, the drive has a logic control ride-thru duration set for 0.25 seconds while idle. This feature ensures temporary stability during brief scenarios when the drive is not running. The drive can maintain power for up to 15 milliseconds at full load, which is critical for applications that might experience sudden power fluctuations.
| Revision Part # | Also known as | |
|---|---|---|
| 20DD077A0ENNA6CNL Ser A | 20DD077A0ENNA6CNL/A, Series A, Rev A | |
| Don't see your particular revision? Contact us now. | ||