| Manufacturer | Allen Bradley |
|---|---|
| Product Type | Adjustable Frequency AC Drive |
| Product Line | PowerFlex 700S |
| Part Number | 20DD500N3NNNBCGNE |
| Weight | 250.00 lbs (113.40 kg) |
| Voltage | 480V AC |
| Phases | 3 |
| 480V Input Amps | 500 |
| Enclosure | Open/IP00 |
| Human Interface Machine | Full Numeric LCD |
| Documentation | No |
| Brake | No |
| Bus Undervoltage Trip | Adjustable |
| Heat Sink Thermistor | Monitored by microprocessor overtemp trip |
| Logic Control Ride-Thru | 0.25 sec., drive not running |
| Power Ride-Thru | 15 milliseconds at full load |
The 20DD500N3NNNBCGNE is a high-capacity adjustable frequency AC drive from Allen-Bradley, part of Rockwell Automation's PowerFlex 700S series. This unit operates efficiently across three-phase electrical systems at a voltage of 480V AC, handling input currents up to 500 amps.
The design features an open enclosure that is rated IP00, making it suitable for deployment in indoor environments where protection against dust and moisture is not a primary concern. Interaction with the drive is facilitated via a full numeric LCD display, providing clear access to operational parameters and settings. There is no provided documentation with the unit.
Notably, the drive does not include braking mechanisms, focusing instead on its adjustable bus undervoltage trip for optimized operation. For thermal management, the heat sink is monitored by a microprocessor-driven thermistor, which oversees temperature levels and triggers an overtemperature trip when required.
In terms of operational stability, the drive offers a logic control ride-thru duration of 0.25 seconds while not running, aiding in maintaining functionality during brief power interruptions. It can also sustain power for a period of 15 milliseconds at full load. The 20DD500N3NNNBCGNE drive is engineered for robust performance in demanding industrial applications, delivering reliable and efficient motor control capabilities.