Product image is representative; revision or series may vary. Contact us to request a specific version.
The Allen-Bradley 20DE170A0ENNBNCNK is a robust adjustable frequency AC drive designed for three-phase applications at 600V AC. This model supports a current input of 170 amps and is suitable for various industrial settings.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Allen Bradley |
|---|---|
| Product Type | Adjustable Frequency AC Drive |
| Product Line | PowerFlex 700S |
| Part Number | 20DE170A0ENNBNCNK |
| Weight | 32.00 lbs (14.51 kg) |
| Voltage | 600V AC |
| Phases | 3 |
| 600V Input Amps | 170 |
| Enclosure | IP20, NEMA Type 1 |
| Human Interface Machine | Blank Cover |
| Documentation | Quick Start Guide |
| Brake | No |
| Bus Undervoltage Trip | Adjustable |
| Heat Sink Thermistor | Monitored by microprocessor overtemp trip |
| Logic Control Ride-Thru | 0.25 sec., drive not running |
| Power Ride-Thru | 15 milliseconds at full load |
The 20DE170A0ENNBNCNK from Allen-Bradley is an adjustable frequency AC drive engineered for optimal performance in industrial applications. Designed for three-phase operation at a voltage of 600V AC, this drive efficiently handles an input current of 170 amps.
Housed in an IP20-rated enclosure compliant with NEMA Type 1 standards, this unit is built to withstand typical indoor conditions, ensuring reliable operation. The model features a blank cover on its human machine interface, streamlining its integration into various systems. A quick start guide is included for straightforward setup and installation.
While the drive does not have a braking system, it does provide adjustable bus undervoltage trip protection, which is a significant feature for maintaining operational safety. Thermal monitoring is achieved through a heat sink thermistor under the control of a microprocessor, which activates an overtemperature trip when necessary.
This drive supports a logic control ride-thru duration of 0.25 seconds when it is not in operation, which aids in maintaining stability during brief power interruptions. Additionally, the 20DE170A0ENNBNCNK can sustain power ride-thru for 15 milliseconds while under full load, providing further assurance in critical applications. This design ensures efficient, reliable operation tailored for demanding industrial environments.
| Revision Part # | Also known as | |
|---|---|---|
| 20DE170A0ENNBNCNK Ser A | 20DE170A0ENNBNCNK/A, Series A, Rev A | |
| Don't see your particular revision? Contact us now. | ||