1391-T015DT

Rated 4.7 with 18 reviews
top legal disclaimer
top legal disclaimer

credit cards accepted
better business bureau

1391-T015DT

Revisions: Ser A 
Description: The Allen-Bradley 1391-T015DT has a 240/480V AC Primary Voltage, 3 Phases, and a 60 Hz Frequency. It also contains a 230V AC Single-Phase C.T. Windings Secondary Voltage.
Available Now
Request a quote for 1391-T015DT

Description:

The Allen-Bradley 1391-T015DT has a 240/480V AC Primary Voltage, 3 Phases, and a 60 Hz Frequency. It also contains a 230V AC Single-Phase C.T. Windings Secondary Voltage.



top legal disclaimer
disclaimer
credit cards
better business bureau
Revisions: Ser A 

Warranty: 1 year DO Supply Warranty Included
Shipping: Worldwide shipping via DHL, UPS, Fedex, and TNT
Repairs: We offer repair service for the 1391-T015DT.
Exchange: Exchange credit for your defective unit available.

To Speak to a sales representative for pricing & lead time:

phone

International
919-205-4392

Rated 4.7 with 18 reviews

    Technical Specifications for 1391-T015DT

ManufacturerRockwell Automation
BrandAllen-Bradley
Part Number/Catalog No.1391-T015DT
Product TypeIsolation Transformer
kVA Rating1.5
Primary Voltage240/480V AC
Phase3
Frequency60 Hz
Secondary Voltage230V AC Single-Phase C.T. Windings
ManufacturerRockwell Automation
BrandAllen-Bradley
Part Number/Catalog No.1391-T015DT
Product TypeIsolation Transformer
kVA Rating1.5
Primary Voltage240/480V AC
Phase3
Frequency60 Hz
Secondary Voltage230V AC Single-Phase C.T. Windings
s

About 1391-T015DT

The 1391-T015DT isolation transformer from Allen-Bradley is an isolation transformer for Allen-Bradley 1391B-ES AC servo controllers. The 1391-T015DT isolation transformer is rated at 1.5 kVA at 60 degrees Celsius. It weighs 27 pounds and measures 10 x 13 x 9 inches. Primary voltages for the 1391-T015DT isolation transformer are 240 to 480 Volts AC (3-phase, 60 Hertz). The secondary voltage rating for the 1391-T015DT isolation transformer is 230 Volts AC (3-phase) and it has four 35.5 Volts AC rated single-phase windings. The isolation transformer power dissipation at 20, 40, 60, 80, and 100% loads are 13, 25, 38, 50, and 60 Watts, respectively. The 1391B-ES controller must be operated from the output of a transformer with 2 outputs rated at 230 Volts AC (3-phase) and 36 Volts AC (single-phase). Transformers supplied with 1391B-ES controllers can provide power for up to 4 controllers.

The 36 Volts AC output from the 1391-T015DT isolation transformer is used to provide power to the logic control board on the 1391B-ES controller. Only technicians trained in the installation of servo systems –which include the 1391B-ES controller and the 1391-T015DT isolation transformer- should plan and implement the servo system. Incorrectly installed servo systems can cause equipment damage or lead to a reduction in the operational life of the system. The servo systems should be panel-mounted in a suitable enclosure which is ventilated with filtered or cooled air. For proper airflow and wring access, a minimum of 3 inches of separation should be maintained around the 1391-T015DT isolation transformer. The air temperature around the 1391-T015DT isolation transformer should be kept lower than 140 degrees Fahrenheit. The installation of servo systems at an altitude above 3300 feet is not recommended.

Repair Services for 1391-T015DT

Type Lead Time Price Action
Repair Service 2-4 weeks $283.97cartAdd to Cart

Our highly skilled technicians can repair your 1391-T015DT. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Revisions for 1391-T015DT

Please refer to the manual for more information about the 1391-T015DT such as the wiring diagrams, data sheets, firmware information and migration or obsolescence details.

Revision Part # Also Known as Availability
1391-T015DT Ser A
1391-T015DT/A, Series A, Rev A Request Quote
Common misspellings:
  • l391-T015DT
  • 139l-T015DT
  • 1391-To15DT
  • 1391-T0l5DT
  • 1391T015DT

Dimensions For 1391-T015DT

Size
Input Type
Panel Cutout Height in mm
Panel Cutout Width in mm
Terminal Height in mm
Terminal Width in mm
Terminal Overall Depth in mm
Terminal Mounted Depth in mm

Dimensions For 1391-T015DT

Resolutions For 1391-T015DT

Technical Specifications
ManufacturerRockwell Automation
BrandAllen-Bradley
Part Number/Catalog No.1391-T015DT
Product TypeIsolation Transformer
kVA Rating1.5
Primary Voltage240/480V AC
Phase3
Frequency60 Hz
Secondary Voltage230V AC Single-Phase C.T. Windings
ManufacturerRockwell Automation
BrandAllen-Bradley
Part Number/Catalog No.1391-T015DT
Product TypeIsolation Transformer
kVA Rating1.5
Primary Voltage240/480V AC
Phase3
Frequency60 Hz
Secondary Voltage230V AC Single-Phase C.T. Windings
About

The 1391-T015DT isolation transformer from Allen-Bradley is an isolation transformer for Allen-Bradley 1391B-ES AC servo controllers. The 1391-T015DT isolation transformer is rated at 1.5 kVA at 60 degrees Celsius. It weighs 27 pounds and measures 10 x 13 x 9 inches. Primary voltages for the 1391-T015DT isolation transformer are 240 to 480 Volts AC (3-phase, 60 Hertz). The secondary voltage rating for the 1391-T015DT isolation transformer is 230 Volts AC (3-phase) and it has four 35.5 Volts AC rated single-phase windings. The isolation transformer power dissipation at 20, 40, 60, 80, and 100% loads are 13, 25, 38, 50, and 60 Watts, respectively. The 1391B-ES controller must be operated from the output of a transformer with 2 outputs rated at 230 Volts AC (3-phase) and 36 Volts AC (single-phase). Transformers supplied with 1391B-ES controllers can provide power for up to 4 controllers.

The 36 Volts AC output from the 1391-T015DT isolation transformer is used to provide power to the logic control board on the 1391B-ES controller. Only technicians trained in the installation of servo systems –which include the 1391B-ES controller and the 1391-T015DT isolation transformer- should plan and implement the servo system. Incorrectly installed servo systems can cause equipment damage or lead to a reduction in the operational life of the system. The servo systems should be panel-mounted in a suitable enclosure which is ventilated with filtered or cooled air. For proper airflow and wring access, a minimum of 3 inches of separation should be maintained around the 1391-T015DT isolation transformer. The air temperature around the 1391-T015DT isolation transformer should be kept lower than 140 degrees Fahrenheit. The installation of servo systems at an altitude above 3300 feet is not recommended.

Repairs
Type Lead Time Price Action
Repair Service 2-4 weeks $283.97cartAdd to Cart

Our highly skilled technicians can repair your 1391-T015DT. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Type Lead Time Price Action
Repair Service 2-4 weeks $283.97cartAdd to Cart

Our highly skilled technicians can repair your 1391-T015DT. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Revisions

Please refer to the manual for more information about the 1391-T015DT such as the wiring diagrams, data sheets, firmware information and migration or obsolescence details.

Revision Part # Also Known as Availability
1391-T015DT Ser A
1391-T015DT/A, Series A, Rev A Request Quote

Common misspellings:
  • l391-T015DT
  • 139l-T015DT
  • 1391-To15DT
  • 1391-T0l5DT
  • 1391T015DT
PDF