The Allen-Bradley 1391-T050DT has a 240/480V AC Primary Voltage, 3 Phases, and a 60 Hz Frequency. It also contains a 230V AC Single-Phase C.T. Windings Secondary Voltage.
Warranty: | 1 year DO Supply Warranty Included |
Shipping: | Worldwide shipping via DHL, UPS, Fedex, and TNT |
Repairs: | We offer repair service for the 1391-T050DT. |
Exchange: | Exchange credit for your defective unit available. |
Manufacturer | Rockwell Automation |
Brand | Allen-Bradley |
Part Number/Catalog No. | 1391-T050DT |
Product Type | Isolation Transformer |
kVA Rating | 5 |
Primary Voltage | 240/480V AC |
Phase | 3 |
Frequency | 60 Hz |
Secondary Voltage | 230V AC Single-Phase C.T. Windings |
Manufacturer | Rockwell Automation |
Brand | Allen-Bradley |
Part Number/Catalog No. | 1391-T050DT |
Product Type | Isolation Transformer |
kVA Rating | 5 |
Primary Voltage | 240/480V AC |
Phase | 3 |
Frequency | 60 Hz |
Secondary Voltage | 230V AC Single-Phase C.T. Windings |
The Allen-Bradley 1391-T050DT isolation transformer is a 5 kVA rated isolation transformer. It is designed for use with Allen-Bradley 1391B-ES servo controllers. In order to maintain the UL listing on Allen-Bradley 1391B-ES controllers, the users must provide power to the 1391B-ES controllers from an Allen-Bradley 1391 isolation transformer. The use of other transformers voids the UL listing. The Allen-Bradley 1391B-ES controllers are available in 15, 22.5, and 45 Amps current ratings. The complete servo system comprises a 1391B-ES controller, a 1391 transformer, a 1326 servo motor, and 1326 cables.
The 1391-T050DT isolation transformer is rated for 5.0 kVA. The primary voltage for the transformer is 240 to 480 Volts AC. The input is 3-phase and the supported line frequency is 60 Hertz. The secondary voltage for the transformer is 3-phase 230 Volts AC voltage. The secondary voltage also includes four 36 Volts AC single-phase rated windings. The 36 Volts AC output on the transformer is used to provide power to the logic control board on the 1391B-ES controller. The 36 Volts AC leads are connected to terminals 19 and 21 on Terminal Block 4 of the controller. The center tap is connected to terminal 20 of Terminal Block 4. The power dissipation for the 1391-T050DT isolation transformer at 20, 40, 60, 80, and 100% rated output is 50, 100, 150, 200, and 250 Watts, respectively. The weight of the 1391-T050DT isolation transformer is 100 pounds and it measures 11 x 14 x 11 inches. The ambient air temperature around the 1391-T050DT isolation transformer must be kept between 0 and 60 degrees Celsius and the relative humidity should be between 5 and 95% (non-condensing).
Type | Lead Time | Price | Action |
---|---|---|---|
Repair Service | 2-4 weeks | Ask | ![]() |
Our highly skilled technicians can repair your 1391-T050DT. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.
Please refer to the manual for more information about the 1391-T050DT such as the wiring diagrams, data sheets, firmware information and migration or obsolescence details.
Revision Part # | Also Known as | Availability |
1391-T050DT Ser A |
1391-T050DT/A, Series A, Rev A | Request Quote |
Size | |
Input Type | |
Panel Cutout Height | in mm |
Panel Cutout Width | in mm |
Terminal Height | in mm |
Terminal Width | in mm |
Terminal Overall Depth | in mm |
Terminal Mounted Depth | in mm |
Manufacturer | Rockwell Automation |
Brand | Allen-Bradley |
Part Number/Catalog No. | 1391-T050DT |
Product Type | Isolation Transformer |
kVA Rating | 5 |
Primary Voltage | 240/480V AC |
Phase | 3 |
Frequency | 60 Hz |
Secondary Voltage | 230V AC Single-Phase C.T. Windings |
Manufacturer | Rockwell Automation |
Brand | Allen-Bradley |
Part Number/Catalog No. | 1391-T050DT |
Product Type | Isolation Transformer |
kVA Rating | 5 |
Primary Voltage | 240/480V AC |
Phase | 3 |
Frequency | 60 Hz |
Secondary Voltage | 230V AC Single-Phase C.T. Windings |
The Allen-Bradley 1391-T050DT isolation transformer is a 5 kVA rated isolation transformer. It is designed for use with Allen-Bradley 1391B-ES servo controllers. In order to maintain the UL listing on Allen-Bradley 1391B-ES controllers, the users must provide power to the 1391B-ES controllers from an Allen-Bradley 1391 isolation transformer. The use of other transformers voids the UL listing. The Allen-Bradley 1391B-ES controllers are available in 15, 22.5, and 45 Amps current ratings. The complete servo system comprises a 1391B-ES controller, a 1391 transformer, a 1326 servo motor, and 1326 cables.
The 1391-T050DT isolation transformer is rated for 5.0 kVA. The primary voltage for the transformer is 240 to 480 Volts AC. The input is 3-phase and the supported line frequency is 60 Hertz. The secondary voltage for the transformer is 3-phase 230 Volts AC voltage. The secondary voltage also includes four 36 Volts AC single-phase rated windings. The 36 Volts AC output on the transformer is used to provide power to the logic control board on the 1391B-ES controller. The 36 Volts AC leads are connected to terminals 19 and 21 on Terminal Block 4 of the controller. The center tap is connected to terminal 20 of Terminal Block 4. The power dissipation for the 1391-T050DT isolation transformer at 20, 40, 60, 80, and 100% rated output is 50, 100, 150, 200, and 250 Watts, respectively. The weight of the 1391-T050DT isolation transformer is 100 pounds and it measures 11 x 14 x 11 inches. The ambient air temperature around the 1391-T050DT isolation transformer must be kept between 0 and 60 degrees Celsius and the relative humidity should be between 5 and 95% (non-condensing).
Type | Lead Time | Price | Action |
---|---|---|---|
Repair Service | 2-4 weeks | Ask | ![]() |
Our highly skilled technicians can repair your 1391-T050DT. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.
Type | Lead Time | Price | Action |
---|---|---|---|
Repair Service | 2-4 weeks | Ask | ![]() |
Our highly skilled technicians can repair your 1391-T050DT. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.
Please refer to the manual for more information about the 1391-T050DT such as the wiring diagrams, data sheets, firmware information and migration or obsolescence details.
Revision Part # | Also Known as | Availability |
1391-T050DT Ser A |
1391-T050DT/A, Series A, Rev A | Request Quote |