Revisions: Ser A 
Description: The Allen-Bradley 1391-T150DT has a 240/480V AC Primary Voltage, 3 Phases, and a 60 Hz Frequency. It also contains a 230V AC Single-Phase C.T. Windings Secondary Voltage.
Available Now
Request a quote for 1391-T150DT

Description:

The Allen-Bradley 1391-T150DT has a 240/480V AC Primary Voltage, 3 Phases, and a 60 Hz Frequency. It also contains a 230V AC Single-Phase C.T. Windings Secondary Voltage.



top legal disclaimer
disclaimer
credit cards
better business bureau
Revisions: Ser A 

Warranty: 1 year DO Supply Warranty Included
Shipping: Worldwide shipping via DHL, UPS, Fedex, and TNT
Repairs: We offer repair service for the 1391-T150DT.
Exchange: Exchange credit for your defective unit available.

To Speak to a sales representative for pricing & lead time:

phone

International
919-205-4392

Rated 4.5 with 12 reviews

    Technical Specifications for 1391-T150DT

ManufacturerRockwell Automation
BrandAllen-Bradley
Part Number/Catalog No.1391-T150DT
Product TypeIsolation Transformer
kVA Rating15
Primary Voltage240/480V AC
Phase3
Frequency60 Hz
Secondary Voltage230V AC Single-Phase C.T. Windings
ManufacturerRockwell Automation
BrandAllen-Bradley
Part Number/Catalog No.1391-T150DT
Product TypeIsolation Transformer
kVA Rating15
Primary Voltage240/480V AC
Phase3
Frequency60 Hz
Secondary Voltage230V AC Single-Phase C.T. Windings
s

About 1391-T150DT

The Allen-Bradley 1391-T150DT isolation transformer has a 15-kVA rating. The 1391-T150DT transformer has a primary input voltage range of 240 to 480 Volts AC. This transformer belongs to the 1391 AC servo series from Allen-Bradley. It is a 3-phase device and it has an operating frequency of 60 Hertz. Isolation transformers like this one are mainly used to transfer electrical power from a source of AC power to another device while isolating the powered device from the main power source. The device should be used and stored within a relative humidity range of 5 to 95%, non-condensing. The input is protected against transient voltage. The device is equipped with a power line D/B contactor which opens the AC line to the drive and inserts a shunt regulator resistor across the DC bus when the contactor is de-energized.

The 1391B-ESAA15 transformer is equipped with a 2-line LCD screen and a programming panel. It is used to feed input and configure the device. The panel has 5 buttons and the LCD can display 2 lines and 16 characters of information at a time. Through the panel, the transformer can be troubleshooted when needed. The device has a patented current control implementation function. The transformer is controlled by using a microprocessor. The logic board houses the microprocessor and it can be easily removed and replaced for diagnostics and troubleshooting. The 1391B-ESAA15 transformer features true vector control. The device supports both linear acceleration and linear deceleration. It can be set by using the control module. Multiple LEDs are located on the front panel to show the status of the transformer.

Repair Services for 1391-T150DT

Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your 1391-T150DT. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Revisions for 1391-T150DT

Please refer to the manual for more information about the 1391-T150DT such as the wiring diagrams, data sheets, firmware information and migration or obsolescence details.

Revision Part # Also Known as Availability
1391-T150DT Ser A
1391-T150DT/A, Series A, Rev A Request Quote
Common misspellings:
  • l391-T150DT
  • 139l-T150DT
  • 1391-Tl50DT
  • 1391-T15oDT
  • 1391T150DT

Dimensions For 1391-T150DT

Size
Input Type
Panel Cutout Height in mm
Panel Cutout Width in mm
Terminal Height in mm
Terminal Width in mm
Terminal Overall Depth in mm
Terminal Mounted Depth in mm

Dimensions For 1391-T150DT

Resolutions For 1391-T150DT

Technical Specifications
ManufacturerRockwell Automation
BrandAllen-Bradley
Part Number/Catalog No.1391-T150DT
Product TypeIsolation Transformer
kVA Rating15
Primary Voltage240/480V AC
Phase3
Frequency60 Hz
Secondary Voltage230V AC Single-Phase C.T. Windings
ManufacturerRockwell Automation
BrandAllen-Bradley
Part Number/Catalog No.1391-T150DT
Product TypeIsolation Transformer
kVA Rating15
Primary Voltage240/480V AC
Phase3
Frequency60 Hz
Secondary Voltage230V AC Single-Phase C.T. Windings
About

The Allen-Bradley 1391-T150DT isolation transformer has a 15-kVA rating. The 1391-T150DT transformer has a primary input voltage range of 240 to 480 Volts AC. This transformer belongs to the 1391 AC servo series from Allen-Bradley. It is a 3-phase device and it has an operating frequency of 60 Hertz. Isolation transformers like this one are mainly used to transfer electrical power from a source of AC power to another device while isolating the powered device from the main power source. The device should be used and stored within a relative humidity range of 5 to 95%, non-condensing. The input is protected against transient voltage. The device is equipped with a power line D/B contactor which opens the AC line to the drive and inserts a shunt regulator resistor across the DC bus when the contactor is de-energized.

The 1391B-ESAA15 transformer is equipped with a 2-line LCD screen and a programming panel. It is used to feed input and configure the device. The panel has 5 buttons and the LCD can display 2 lines and 16 characters of information at a time. Through the panel, the transformer can be troubleshooted when needed. The device has a patented current control implementation function. The transformer is controlled by using a microprocessor. The logic board houses the microprocessor and it can be easily removed and replaced for diagnostics and troubleshooting. The 1391B-ESAA15 transformer features true vector control. The device supports both linear acceleration and linear deceleration. It can be set by using the control module. Multiple LEDs are located on the front panel to show the status of the transformer.

Repairs
Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your 1391-T150DT. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your 1391-T150DT. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Revisions

Please refer to the manual for more information about the 1391-T150DT such as the wiring diagrams, data sheets, firmware information and migration or obsolescence details.

Revision Part # Also Known as Availability
1391-T150DT Ser A
1391-T150DT/A, Series A, Rev A Request Quote

Common misspellings:
  • l391-T150DT
  • 139l-T150DT
  • 1391-Tl50DT
  • 1391-T15oDT
  • 1391T150DT
PDF