The Allen-Bradley/Rockwell Automation 100-A09NB3 contactor is a 3-pole non-reversing contactor from the Bulletin 100 product line. It is rated for 9 Amps of current and 600 Volts AC. The 100-A09NB3 contactor has a minimum horsepower rating of 2 Horsepower and a maximum rating of 7.5 Horsepower.
We sell industrial automation parts backed by our 2-year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
Manufacturer | Allen-Bradley/Rockwell Automation |
---|---|
Series | 100 Contactors |
Part Number | 100-A09NB3 |
Product Type | Contactor |
Contactor Type | AC Magnetic Contactor |
Number of Poles | 3 |
Number of Phases | 3 |
Frequency | 50 to 60 Hertz |
Auxiliary Contact | Normally Open |
Reversing Type | Non-Reversing |
The 100-A09NB3 contactor is a 600 Volts 3-phase contactor that has been designed and manufactured by Allen-Bradley/Rockwell Automation. It is a 3-pole type of contactor with a minimum and maximum coil voltage of 480 Volts each. Its current rating is 9 Amps. The 100-A09NB3 contactor is a non-reversing type of contactor. It is suitable for applications in the Allen-Bradley Bulletin 100 motor control systems. It comes with 1 auxiliary contact that is normally open. The horsepower output ratings that the 100-A09NB3 contactor supports include 2 Horsepower at 200 Volts, 2 Horsepower at 230 Volts, 5 Horsepower at 460 Volts, and 7.5 Horsepower at 575 Volts. The 100-A09NB3 3-phase contactor has a frequency rating of 50 to 60 Hertz.
The Allen-Bradley/Rockwell Automation 100-A09NB3 3-phase 600 Volts rated contactor with 3 poles uses an enclosure for protection against common substances in industrial environments like dust, small debris, and moderate levels of moisture. It has a green start button, a red stop button, and a gray reset button on the front panel which make it easy to control during normal operation and easy to reset after an error or power failure. The 100-A09NB3 3-phase contactor also has an AC magnetic contactor feature. This contactor has been designed to be compact in order to conserve energy and to save panel space. It is easy to install and it leaves more free space around it than other contactors, which may allow more devices to be installed around it and allow it to be part of more sophisticated and elaborate industrial automation systems than other contactors.