Product image is representative; revision or series may vary. Contact us to request a specific version.
The Allen-Bradley 100S-D180EA22C contactor is a 3-pole 100 series AC contactor. Its rated current is 180 Amps at 60 degrees Celsius. The 100S-D180EA22C contactor includes a PLC interface.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Allen Bradley |
|---|---|
| Product Type | Contactor |
| Product Line | 100 Contactors |
| Part Number | 100S-D180EA22C |
| Weight | 8.94 lbs (4.05 kg) |
| Coil | Electronic |
| Coil Voltage | 208 to 277 Volts AC |
| Poles | 3 |
| PLC Interface | Yes |
| Current Rating | 180 Amps |
| Altitude | 2000 Meters |
| Storage Temperature | -25 to 60 degrees Celsius |
| Operating Temperature | -40 to 80 degrees Celsius |
| NC Contacts | 2 |
The Allen-Bradley 100S-D180EA22C contactor is a safety contactor. Its rated operational current at 60 degrees Celsius and 400 Volts AC is 180 Amps. Its rated operational current at 40 degrees Celsius and 690 Volts AC is 250 Amps. The 100S-D180EA22C contactor can support the following output power ratings for AC motors at 50 Hertz frequency: 55 kilowatts at 230 Volts AC, 101 kilowatts at 400 Volts AC, 100 kilowatts at 15 Volts AC, 90 kilowatts at 500 Volts AC, 132 kilowatts at 690 Volts AC, 90 kilowatts at 1000 Volts AC, and 50 kilowatts at 200 Volts AC. The 100S-D180EA22C contactor can support the following ratings for AC motors at 60 Hertz frequency, 60 Horsepower at 230 Volts AC, 150 Horsepower at 460 Volts AC, and 150 Horsepower at 575 Volts AC.
The 100S-D180EA22C contactor is equipped with 2 normally open contacts and 2 normally closed contacts. The 100S-D180EA22C contactor is a 3-pole device. The coil on the contactor is of the electronic type. The Bulletin 100S-D contactors are designed with electronic or conventional coils and these contacts support AC or DC operation. Bulletin 100S-D contactors like the 100S-D180EA22C contactor include integrated PLC interfaces and they feature wide voltage ranges and lower power pick-up and hold-in functions. The Bulletin 100S-D contactors are designed for applications involving isolating switchgear which is used in hazardous motion loads. All contactors should be disconnected from their power source before they are serviced. Allen Bradley contactors are designed for installation inside a suitable enclosure for protection from contaminants. Phase barriers should be installed on the 100S-D180EA22C contactor before operation.