| Manufacturer | Allen Bradley |
|---|---|
| Product Type | Contactor |
| Product Line | 100 Contactors |
| Part Number | 100S-D180EZJ22C |
| UPC | 781180505171 |
| Weight | 12.00 lbs (5.44 kg) |
| Coil | Electronic |
| Coil Voltage | 24 Volts DC |
| PLC Interface | Yes |
| Poles | 3 |
| NC Contacts | 2 |
| NO Contacts | 2 |
| Altitude | 2000 meters |
| Isolation Voltage | 1000 Volts |
| Operating Temperature | -25 to 60 degrees Celsius |
The Allen-Bradley 100S-D180EZJ22C contactor is a Bulletin 100S-D contactor. It features an electronically controlled DC coil that is rated for 24 Volts DC. The 100S-D180EZJ22C contactor also features 2 normally closed contacts and 2 normally open contacts. The operating current rating for the 100S-D180EZJ22C contactor when it is being operated with DC input is 180 Amps at 400 Volts and 60 degrees Celsius and 250 Amps at 690 Volts and 40 degrees Celsius. The optimal operation of the contactor requires a maximum altitude of less than or equal to 2000 meters above sea level and ambient temperature range between -25 and 60 degrees Celsius. When the contactor is in storage or is being transported, the ambient temperature should be maintained between -40 and 80 degrees Celsius. The IEC isolation rating of the contactor is 1000 Volts.
The 100S-D180EZJ22C contactor is a 3-pole safety contactor. It belongs to the Bulletin 100S-D safety contactors product line which supports 63 to 500 kilowatts of output at 400 Volts, 75 to 600 Horsepower of output at 460 Volts, and 100 to 700 Horsepower of output at 575 Volts. Contactors are available with electronic and conventional coils. The complete range of accessories that are available for the contactors include auxiliary contacts and suppressor modules. Allen-Bradley contactors like the 100S-D180EZJ22C contactor should be installed and maintained by qualified technicians only. The main contacts and arc chute on the contactor must be examined after a short circuit occurs. Contactors must be operated with phase barriers in place. Reliable stopping requires the disconnection of the control voltages. The power to the 100S-D180EZJ22C contactor should be disconnected prior to any maintenance work to prevent electrical shock. The 100S-D180EZJ22C contactor should be protected from all contaminants.