Product image is representative; revision or series may vary. Contact us to request a specific version.
The Allen-Bradley 100S-D180ZJ33LC contactor is a DC controlled 100 series contactor. The DC coil on the 100S-D180ZJ33LC contactor is rated for 24 Volts DC. The 100S-D180ZJ33LC contactor has a total of 6 auxiliary contacts.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Allen Bradley |
|---|---|
| Product Type | Contactor |
| Product Line | 100 Contactors |
| Part Number | 100S-D180ZJ33LC |
| Weight | 9.88 lbs (4.48 kg) |
| Coil | Electronic |
| Coil Voltage | 24 Volts DC |
| NO Contacts | 3 |
| NC Contacts | 3 |
| PLC Interface | Yes |
| Altitude | 2000 Meters |
| Rated Current | 180 Amps |
| Operating Temperature | -25 to 60 degrees Celsius |
| Storage Temperature | -40 to 80 degrees Celsius |
The 100S-D180ZJ33LC contactor is a DC operated contactor. The coil on the contactor is electronically controlled and it is rated for 24 Volts DC operation. The 100S-D180ZJ33LC contactor features 3 normally closed and 3 normally open contacts. One of the normally closed contacts on the 100S-D180ZJ33LC contactor is a late break. The performance specifications for the 100S-D180ZJ33LC contactor include 180 Amps and 250 Amps current ratings at 400 and 690 Volts, respectively. The contactor can be used to control AC motors with the following output power ratings at 60 Hertz: 150 Horsepower at 460 Volts and 575 Volts and 60 Horsepower at 230 Volts. The contactor can be used to control AC motors with following output power ratings at 50 Hertz: 132 kilowatts at 690 Volts, 100 kilowatts at 415 Volts, 55 kilowatts at 230 Volts, and 50 kilowatts at 200 Volts.
The 100S-D180ZJ33LC contactor is a safety contactor. If a power contact welds for any reason, the normally closed contacts do not change their state. This feature is provided to give a reliable indication about the closed or open status of the main power poles. The 100S-D180ZJ33LC contactor is a 3-pole contactor. The contactors which are part of the Bulletin 100S-D series like the 100S-D180ZJ33LC contactor are specially designed for safety applications requiring the monitoring and feedback of energy-isolating switchgear that is used in hazardous motion loads. These special application needs are met through the mirror contact design of the safety contactors. The 100S-D180ZJ33LC contactor has compact dimensions and a built-in PLC interface. For optimal operation, Allen-Bradley recommends use of a suitable enclosure for contactor installation. To prevent malfunctions, the contactor should be protected from all types of contaminants.