Product image is representative; revision or series may vary. Contact us to request a specific version.
The 100S-D420ED22C contactor is an Allen-Bradley 3-pole contactor. It features an electronic coil. The contactor coil is AC controlled.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Allen Bradley |
|---|---|
| Product Type | Contactor |
| Product Line | 100 Contactors |
| Part Number | 100S-D420ED22C |
| UPC | 781180451287 |
| Weight | 20.00 lbs (9.07 kg) |
| Coil | Electronic |
| Coil Voltage | 110 to 130 Volts AC |
| Rated Current | 420 Amps |
| PLC Interface | Yes |
| Altitude | 2000 meters |
| Operating Temperature | -25 to 60 degrees Celsius |
| Storage Temperature | -40 to 80 degrees Celsius |
| NC Contacts | 2 |
| NO Contacts | 2 |
The 100S-D420ED22C contactor is a 3-pole Bulletin 100S-D safety contactor from Allen-Bradley. The Bulletin 100S-D contactors include a mirror contact safety design to prevent normally closed contacts from changing their state in the event of a power contact weld. This feature leads to reliable indications about the status of the main power poles on the contactors. The Bulletin 100S-D safety contactors were designed by Allen-Bradley to satisfy the requirements of industrial applications requiring the monitoring and feedback of the isolating switchgear used in hazardous motion loads. Allen-Bradley also provides a wide range of IEC contactors for a wide range of industrial applications. These are available in compact and large sizes and a wide range of current ratings. The operating current rating of the 100S-D420ED22C contactor depends on ambient temperature: it is 420 Amps at 60 degrees Celsius and 540 Amps at 40 degrees Celsius.
The Allen-Bradley Bulletin 100S-D 100S-D420ED22C contactor features an electronic coil which is rated for 110 to 130 Volts AC. There are 4 auxiliary contacts that are also available on the 100S-D420ED22C contactor. These include 2 of the normally open type and 2 of the normally closed type. A PLC interface is also available on the contactor. The 3-phase motors that are the switching type can be controlled by the 100S-D420ED22C contactor. The motor ratings for which the 100S-D420ED22C contactor has been tested include 132 kilowatts at 230 Volts and 50 Hertz, 250 kilowatts at 415 Volts and 50 Hertz, 420 kilowatts at 500 Volts and 50 Hertz, 150 Horsepower at 200 Volts and 60 Hertz, 350 Horsepower at 460 Volts and 60 Hertz, and 400 Horsepower at 575 Volts and 60 Hertz.