Product image is representative; revision or series may vary. Contact us to request a specific version.
The 100S-C97KF14BC is a safety contactor manufactured by Allen Bradley, featuring a rated operational current of 97 A under AC-3 conditions. This unit is designed with a 3-pole configuration and includes three normally open contacts for main operation, complemented by auxiliary contacts.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Allen Bradley |
|---|---|
| Product Type | Safety Contactor |
| Product Line | 100S-C Safety Contactors |
| Part Number | 100S-C97KF14BC |
| Rated Operational (Main) Current—AC-3 | 97 A |
| Contact Configuration | 3 Normally Open (3 N.O.) |
| Number of Poles | 3 Poles |
| Auxiliary Contact Configuration | 1 N.O. + 4 N.C. auxiliary contacts |
| Coil Termination | Line-side coil termination |
| Minimum Storage Temperature | 0 °C |
| Maximum Storage Temperature | 40 °C |
| Minimum Operating Temperature | 0 °C |
| Maximum Operating Temperature | 40 °C |
| Maximum Operating Humidity | 80% (Non-Condensing) |
| Storage Humidity | 80% Max. (Non-Condensing) |
| Installation Altitude | 1000 MSL |
The Allen Bradley 100S-C97KF14BC functions as a reliable safety contactor with an impressive rated operational current of 97 A, suitable for AC-3 applications. It features a total of three poles configured with normally open contacts to effectively manage electrical loads. In addition to the main contacts, this unit incorporates one normally open auxiliary contact alongside four normally closed auxiliary contacts, enhancing its operational flexibility.
Coil termination is arranged on the line side, resulting in straightforward wiring arrangements. The device is designed for dependable performance within a controlled environment, with a storage temperature threshold that ranges from a minimum of 0 °C to a maximum of 40 °C. The contactor also adheres to operational temperature limits of 0 °C to 40 °C, ensuring that functionality is maintained in standard conditions.
Humidity considerations have been accounted for in the design, with a maximum operating humidity specification of up to 80% permissible during non-condensing conditions. Accordingly, the contactor is suitable for environments where moisture levels may fluctuate. Additionally, this unit can be installed at altitudes up to 1000 meters above sea level, making it versatile for various applications.