Allen Bradley 140M Circuit Breakers 140M-C2E-B63

Product image is representative; revision or series may vary. Contact us to request a specific version.

140M-C2E-B63

|

The 140M-C2E-B63 is a motor protection circuit breaker from Allen-Bradley. This electrical device is mainly used for branch circuit disconnect, Magnetic protection, Overload protection, and manual switching. This device is a C-Frame circuit breaker with a rated operational current of 6.3 Amperes and an adjustment range of 4.0 - 6.3 Amperes while the magnetic trip current is 82 Amperes.

In Stock
Ships from Raleigh, NC
2 Year DO Supply Warranty
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more
Rockwell Disclaimer: The product is used surplus. DO Supply is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because DO Supply is not an authorized distributor of this product, the Original Manufacturer's warranty does not apply. While many Allen-Bradley PLC products will have firmware already installed, DO Supply makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. DO Supply also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source. DO Supply also makes no representations as to your right to install any such firmware on the product. DO Supply will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Technical specifications for 140M-C2E-B63

ManufacturerAllen Bradley
Product TypeCircuit Breaker
Product Line140M Circuit Breakers
Part Number140M-C2E-B63
UPC662468964357
Weight0.75 lbs (0.34 kg)
Product Family140 Motor Protection circuit breakers
Voltage Rating600 Volts AC
Rated operational current6.3 Amperes
Operating Current6.3 Amps
Motor current adjustment range4.0-6.3 Amperes
Adjustable Motor Current4 to 6.3 Amps
Maximum short circuit current100 kA @ 400V; 65 kA at 480 V (group motor)
Magnetic Trip Current82 Amperes
FrameC
Motor Protection TypeStandard
Breaking capacityNormal break
MountingDIN Rail
Protection typeAdj. thermal / Fixed mag
ApplicationsBranch circuit disconnect; Magnetic protection; Overload protection; Manual switching
No. of Poles3 Poles
Standard complianceCSA22.2, No.14; UL508 (Group Installation); IEC60947-2; CE; CCC
AccessoriesExternal Rotary Operator; Auxiliary Contacts; Trip Indication Contacts

The 140M-C2E-B63 is an Allen-Bradley circuit breaker from the 140M Motor protection circuit breakers. This protective electrical device is primarily intended to implement branch circuit protection acting as a disconnect switch, Magnetic protection, Thermal or Overload protection as well as implementing manual control. The 140M-C2E-B63 may come in Two (2) cULus Listings such as manual and self-protected combination motor controller or as a manual motor controller. This circuit breaker has 3-poles making it compatible for use in 3-phase power systems. has rated operational current of 6.3 Amperes with a motor adjustment range of 4.0-6.3 Amperes and magnetic trip current of 82 Amperes. It has a maximum short circuit current rating of 100 kA at 400 V and 65 kA at 480 V (group motor). The 140M-C2E-B63 has maximum 3-Phase power (Hp) ratings of 1.5 HP at 200 V; 2 Hp at 230 V; 5 Hp at 460 V and 575 V. It also has maximum 3-phase power (kW) rating of 1.5 kW at 230 V; 2.2 kW at 400V / 415 V; 3 kW at 500 V and 4 kW at 690 V. The 140M-C2E-B63 complies to a variety of standards such as CSA22.2, No.14, UL508 (Group Installation), IEC60947-2, CE, and CCC. This circuit breaker is also designed to be installed with accessory modules such as an external rotary operator, auxiliary contact blocks for use in sequencing or interlocking with other systems and processes; Trip indication contacts for depicting the trip state of the breaker. This circuit breaker supports mounting to a standard 35 mm DIN Rail.

The 140M-C2E-B63 circuit breaker is an Allen-Bradley/Rockwell Automation circuit breaker from the 140M Circuit Breakers series. It is a 3-pole type of circuit breaker with a Frame C type of frame. The 140M-C2E-B63 circuit breaker is designed to be DIN Rail mounted when it is installed. Its voltage rating is 600 Volts AC. This circuit breaker has been CE-certified and it is used to protect industrial motors and to reduce downtime. The maximum 3-phase kilowatt output ratings that the 140M-C2E-B63 circuit breaker can handle are 1.5 kilowatts at 230 Volts, 2.2 kilowatts at 400 and 415 Volts, 3 kilowatts at 500 Volts, and 4 kilowatts at 690 Volts. Additionally, this circuit breaker’s maximum 3-phase Horsepower output ratings are 1.5 Horsepower at 200 Volts, 2 Horsepower at 230 Volts, and 5 Horsepower 460 Volts and 575 Volts. The Allen-Bradley/Rockwell Automation 140M-C2E-B63 circuit breaker from the 140M Circuit Breakers series has a rated operating current of 6.3 Amps and a supported adjustable motor current range between 4 and 6.3 Amps. It also has a magnetic trip current rating of 82 Amps. The 140M-C2E-B63 circuit breaker is designed to provide a standard degree of motor protection. If a motor requires a higher degree of motor protection or a more specific kind of motor protection such as a high inrush type of motor protection or protection for motor circuits, a circuit breaker that is specifically designed to provide those types of protection should be used instead of the 140M-C2E-B63 circuit breaker. The minimum contactor size that this circuit breaker supports is size 100-C09.