Product image is representative; revision or series may vary. Contact us to request a specific version.
The Allen-Bradley 140M-D8E-C16 circuit breaker is a 140M circuit breaker. It is designed for the protection of motors. The 140M-D8E-C16 circuit breaker is a D-frame breaker.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Allen Bradley |
|---|---|
| Product Type | Circuit Breaker |
| Product Line | 140M Circuit Breakers |
| Part Number | 140M-D8E-C16 |
| UPC | 662468964456 |
| Weight | 1.00 lbs (0.45 kg) |
| Frame | D |
| Current Rating | 16 Amps |
| Current Range | 10 to 16 Amps |
| Overload Protection | Yes |
| Short Circuit Protection | Yes |
| Magnetic Trip | 208 Amps |
| Poles | 3 |
| Color | Black |
| Three-Phase Operation | Yes |
The 140M-D8E-C16 circuit breaker is an Allen-Bradley Bulletin 140M motor protection circuit breaker. The 140M-D8E-C16 circuit breaker is a D-frame breaker. The D-frame breakers are rated for a maximum of 32 Amps of current, they are available in 1.6 to 32 Amps current ratings, and they feature short circuit protection, overload protection, a high magnetic trip, a standard magnetic trip, and a magnetic only trip. Accessories for D-frame circuit breakers include an external rotary operator, auxiliary contacts, and trip indication contacts. The trip rating of the 140M-D8E-C16 circuit breaker is 16 Amps and the adjustable trip range is 10 to 16 Amps. The magnetic trip current for the breaker is 208 Amps. The maximum short circuit current ratings at 400 Volts and 480 Volts (group motor) are 100 kiloamps and 65 kiloamps, respectively.
The 140M-D8E-C16 circuit breaker is a 3-pole circuit breaker which supports 3-phase operation. The color of the breaker is black. The maximum voltage rating is 600 Volts AC. The maximum 3-phase power ratings for the 140M-D8E-C16 circuit breaker are 15 Horsepower at 575 Volts AC, 10 Horsepower at 460 Volts AC, and 5 Horsepower at 200/230 Volts AC. The maximum power ratings for the circuit breaker are 13 kilowatts at 690 Volts AC, 10 kilowatts at 500 Volts AC, 7.5 kilowatts at 400/415 Volts AC, and 4 kilowatts at 230 Volts AC. The maximum fuse size recommended for use with the 140M-D8E-C16 circuit breaker is 450 Amps. The Bulletin 140M breakers are certified by the CE, CCC, and cULus standards. They are also listed for compliance with standards including the UL 508, CSA C22, and IEC/EN 60947 standards.