Product image is representative; revision or series may vary. Contact us to request a specific version.
The Allen Bradley 1497-N27 is a control circuit transformer designed to effectively reduce supply voltages in control systems. This part supports primary voltage levels of 240/480 volts and operates at a frequency of 60 Hz.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Allen Bradley |
|---|---|
| Product Type | Control Circuit Transformers |
| Product Line | 1497 Transformers |
| Part Number | 1497-N27 |
| Weight | 4.44 lbs (2.01 kg) |
| Secondary Fuse | Included |
| Secondary Fuse Block | Included |
| Spare Part/Accessory | Yes |
| Primary Voltage | 240/480V |
| Primary Frequency | 60 Hz |
| Function | Reduces supply voltages in control circuits |
| Operating Temperature | 32 to 104 degrees Fahrenheit |
| Storage Temperature | 32 to 122 degrees Fahrenheit |
| Maximum Operating Humidity | 80% RH, non-condensing |
| Maximum Storage Humidity | 80% RH, non-condensing |
| Maximum Operating Altitude | 1000m above sea level without derating |
| Maximum Storage Altitude | 1000m above sea level without derating |
The 1497-N27 control circuit transformer from Allen Bradley is constructed specifically for the reduction of supply voltages in control circuit applications, ensuring optimal performance. This transformer operates at a primary voltage of either 240 or 480 volts, while functioning on a 60 Hz frequency, making it suitable for various industrial setups. Included with this transformer are both a secondary fuse and a secondary fuse block, fostering enhanced operational safety during installations.
Built to perform within a temperature range of 32 to 104 degrees Fahrenheit, the 1497-N27 transformer also ensures stability under humid conditions with a maximum operating humidity rating of 80% relative humidity, provided conditions are non-condensing. For storage purposes, it remains effective within a temperature range of 32 to 122 degrees Fahrenheit, maintaining its robustness in a variety of conditions. Additionally, the transformer is rated for storage and operation at altitudes up to 1000 meters above sea level without incurring any reduction in performance. This control circuit transformer is an essential component for providing reliable power management in control circuits and can also serve as a suitable spare part or accessory when needed.