190S-ANKD2-CC10C-JE-KN

190S-ANKD2-CC10C-JE-KN

Description: The Allen-Bradley 190S-ANKD2-CC10C-JE-KN starter is a DOL starter. The starter is made up of two components: a contactor and a circuit breaker. 
Rated 5 with 10 reviews
top legal disclaimer
top legal disclaimer

credit cards accepted
better business bureau

Available Now

Submit RFQ for 190S-ANKD2-CC10C-JE-KN

Add more parts to quote

Description:

The Allen-Bradley 190S-ANKD2-CC10C-JE-KN starter is a DOL starter. The starter is made up of two components: a contactor and a circuit breaker. 



Warranty: 1 year DO Supply Warranty Included
Shipping: Worldwide shipping via DHL, UPS, Fedex, and TNT
Repairs: We offer repair service for the 190S-ANKD2-CC10C-JE-KN.
Exchange: Exchange credit for your defective unit available.

To Speak to a sales representative for pricing & lead time:

phone

International
919-205-4392

Rated 5 with 10 reviews

    Technical Specifications for 190S-ANKD2-CC10C-JE-KN

BrandAllen-Bradley / Rockwell Automation
Series190 Starters
Part Number190S-ANKD2-CC10C-JE-KN
Product typeDOL starter with MPCB
Contactor size100-C09
Coil voltage24 Volts AC
Circuit breaker current range6.3 to 10 Amps
Coil accessoriesElectronic interfaces
Circuit breaker accessoriesLockable twist knob
BrandAllen-Bradley / Rockwell Automation
Series190 Starters
Part Number190S-ANKD2-CC10C-JE-KN
Product typeDOL starter with MPCB
Contactor size100-C09
Coil voltage24 Volts AC
Circuit breaker current range6.3 to 10 Amps
Coil accessoriesElectronic interfaces
Circuit breaker accessoriesLockable twist knob
s

About 190S-ANKD2-CC10C-JE-KN

The 190S-ANKD2-CC10C-JE-KN starter is an Allen-Bradley DOL starter. It also contains a Bulletin 140M MPCB (motor protection circuit breaker). In addition to the circuit breaker, the starter contains a Bulletin 100-C contactor. Most of the Bulletin 140M breakers used for the 190S starters are UL listed. Even though many tests are involved, a critical test which a combination motor protection controller needs to pass is to be able to perform 4000 mechanical operations and 6000 electrical operations after a short circuit. The combination of the 140M circuit breaker and 100-C contactor can be listed as a Type E self-protected combination motor controller. In this case, the 100-C and 140M needs to pass the 4000 mechanical tests and the 6000 electrical operational tests. In some cases, doing this may require the oversizing of the 140M breaker or the 100-C contactor to achieve weld-free performance.

 

The 190S-ANKD2-CC10C-JE-KN starter is comprised of the combination of the contactor and circuit breaker. The size of contactor on the 190S-ANKD2-CC10C-JE-KN starter is 100-C09. The voltage rating for the coil on the starter is 24 Volts AC at 50 Hertz. The contactor also has one auxiliary contact which is normally open (N.O.). The size of the circuit breaker on the starter is the C Frame size. The range for circuit breaker current is 6.3 to 10 Amps. There is one normally open (N.O.) and one normally closed (N.C) auxiliary contact on the starter circuit breaker. The coil accessories on the 190S-ANKD2-CC10C-JE-KN starter include electronic interfaces. Circuit breaker accessories include 1 lockable twist knob. It should be verified that the circuit breaker can be configured to the rated motor current.

Repair Services for 190S-ANKD2-CC10C-JE-KN

Type Lead Time Price Action
Repair Service 2-4 weeks $263.92cartAdd to Cart

Our highly skilled technicians can repair your 190S-ANKD2-CC10C-JE-KN. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Dimensions For 190S-ANKD2-CC10C-JE-KN

Size
Input Type
Panel Cutout Height in mm
Panel Cutout Width in mm
Terminal Height in mm
Terminal Width in mm
Terminal Overall Depth in mm
Terminal Mounted Depth in mm

Dimensions For 190S-ANKD2-CC10C-JE-KN

Resolutions For 190S-ANKD2-CC10C-JE-KN

Technical Specifications
BrandAllen-Bradley / Rockwell Automation
Series190 Starters
Part Number190S-ANKD2-CC10C-JE-KN
Product typeDOL starter with MPCB
Contactor size100-C09
Coil voltage24 Volts AC
Circuit breaker current range6.3 to 10 Amps
Coil accessoriesElectronic interfaces
Circuit breaker accessoriesLockable twist knob
BrandAllen-Bradley / Rockwell Automation
Series190 Starters
Part Number190S-ANKD2-CC10C-JE-KN
Product typeDOL starter with MPCB
Contactor size100-C09
Coil voltage24 Volts AC
Circuit breaker current range6.3 to 10 Amps
Coil accessoriesElectronic interfaces
Circuit breaker accessoriesLockable twist knob
About

The 190S-ANKD2-CC10C-JE-KN starter is an Allen-Bradley DOL starter. It also contains a Bulletin 140M MPCB (motor protection circuit breaker). In addition to the circuit breaker, the starter contains a Bulletin 100-C contactor. Most of the Bulletin 140M breakers used for the 190S starters are UL listed. Even though many tests are involved, a critical test which a combination motor protection controller needs to pass is to be able to perform 4000 mechanical operations and 6000 electrical operations after a short circuit. The combination of the 140M circuit breaker and 100-C contactor can be listed as a Type E self-protected combination motor controller. In this case, the 100-C and 140M needs to pass the 4000 mechanical tests and the 6000 electrical operational tests. In some cases, doing this may require the oversizing of the 140M breaker or the 100-C contactor to achieve weld-free performance.

 

The 190S-ANKD2-CC10C-JE-KN starter is comprised of the combination of the contactor and circuit breaker. The size of contactor on the 190S-ANKD2-CC10C-JE-KN starter is 100-C09. The voltage rating for the coil on the starter is 24 Volts AC at 50 Hertz. The contactor also has one auxiliary contact which is normally open (N.O.). The size of the circuit breaker on the starter is the C Frame size. The range for circuit breaker current is 6.3 to 10 Amps. There is one normally open (N.O.) and one normally closed (N.C) auxiliary contact on the starter circuit breaker. The coil accessories on the 190S-ANKD2-CC10C-JE-KN starter include electronic interfaces. Circuit breaker accessories include 1 lockable twist knob. It should be verified that the circuit breaker can be configured to the rated motor current.

Repairs
Type Lead Time Price Action
Repair Service 2-4 weeks $263.92cartAdd to Cart

Our highly skilled technicians can repair your 190S-ANKD2-CC10C-JE-KN. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Type Lead Time Price Action
Repair Service 2-4 weeks $263.92cartAdd to Cart

Our highly skilled technicians can repair your 190S-ANKD2-CC10C-JE-KN. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

PDF