| Manufacturer | Allen Bradley |
|---|---|
| Product Type | Overload Relay |
| Product Line | 592 Overload Relays |
| Part Number | 592-EC3ED |
| Weight | 10.00 lbs (4.54 kg) |
| Type | Semiconductor |
| Size | 3 |
| Current Range | 18 to 90 Amps |
| Communication | DeviceNet |
| Inputs | 4 |
| Outputs | 2 |
| Three-Phase Operation | Yes |
| Single-Phase Operation | Yes |
| RF Immunity | 10 Volts per Meter |
The 592-EC3ED module is an Allen-Bradley Bulletin 592 overload relay module. The current rating for the device is 18 to 90 Amps and the Bulletin 500 contactor size is Size 3. The integrated I/O on the 592-EC3ED relay module include 4 inputs and 2 outputs. The inputs are current sinking inputs and they require a 24 Volts DC power supply. The on-state voltage for the inputs is 15 Volts DC and the on-state current is 2 milliamps. The steady state current for the inputs is 8 milliamps. The off-state voltage for the inputs is 5 Volts DC and the off-state current is 0.5 milliamps. The transition voltage for the inputs on the overload relay is 5 to 15 Volts DC. The transition current for the inputs is 0.5 to 2 milliamps.
The EMC compatibility specifications for the 592-EC3ED module include electrostatic discharge immunity for 8 kilovolts of air discharge and 6 kilovolts of static discharge. The RF immunity is tested for 10 Volts per meter. The electrical fast transient/burst immunity is tested at 4 kilovolts for power and 2 kilovolts for control and communication. The surge immunity has been tested at 2 kilovolts (L-E) and 1 kilovolt (L-L). The 592-EC3ED module is rated for Class A radiated emissions and Class A conducted emissions. The 592-EC3ED module includes an integrated DeviceNet interface which supports 125, 250, and 500 kbps data rates. The DeviceNet interface supports cyclic messaging, full parameter object support, configuring consistency values, and polled I/O messaging. The interface also supports auto baud-rate identification. The 592-EC3ED module is designed for single-phase and 3-phase operation.